Automated Ambulatory Blood Pressure Monitoring
Number: 0025
Table Of Contents
PolicyApplicable CPT / HCPCS / ICD-10 Codes
Background
References
Policy
Scope of Policy
This Clinical Policy Bulletin addresses automated ambulatory blood pressure monitoring.
-
Medical Necessity
Aetna considers automated ambulatory blood pressure monitoring medically necessary according to the selection criteria listed below, which are based, in part, on guidelines developed by the American College of Physicians.
Note: Ambulatory blood pressure monitoring for less than 24 hours or more than 3 days is not considered medically necessary; repeat testing is not generally necessary more frequently than every 6 months.
Member must meet any of the following criteria:
-
Office or "white coat" hypertension
Ambulatory blood pressure monitoring is considered a medically necessary preventive service for screening to confirm the diagnosis of hypertension and distinguish "white coat" hypertension or a transient rise of blood pressure that occurs in the office setting. The member must have a minimum of two blood pressure readings in the office setting taken on separate days that are repeatedly elevated (systolic readings of 140 mm Hg or greater and/or diastolic readings of 90 mm Hg or greater in adults, or greater than 90th percentile for age, gender and height in children (see appendix)). -
Episodic hypertension
Ambulatory blood pressure monitoring is considered medically necessary for members whose symptomatology (paroxysms of excessive sweating, palpitations, apprehension) suggests episodic hypertension secondary to an adrenal tumor (e.g., pheochromocytoma), and office blood pressure measurements are repeatedly normal.
-
Evaluation of hypotensive symptoms
Ambulatory blood pressure monitoring is considered medically necessary for members with hypotensive symptoms and/or syncopal events that are thought to be related to anti-hypertensive medications.
-
Evaluation of syncope
Ambulatory blood pressure monitoring is considered medically necessary when used in conjunction with a 24-hour Holter monitor (see CPB 0019 - Holter Monitors) to determine whether symptoms of syncope or near syncope are the direct result of an arrhythmia.
-
Nocturnal angina
Ambulatory blood pressure monitoring is considered medically necessary to investigate blood pressure changes in members with nocturnal angina.
-
Resistant hypertension
Ambulatory blood pressure monitoring is considered medically necessary prior to instituting an invasive investigation (e.g., renin vein assays, angiogram for renal artery stenosis) for secondary causes of hypertension for members with hypertension that is refractory to medications.
-
-
Experimental and Investigational
Aetna considers the use of ambulatory blood pressure monitoring experimental and investigational in any of the following situations because the medical literature does not support its use in these conditions:
-
For blood pressure monitoring of persons with heart failure; or
-
For blood pressure monitoring of pregnant women who do not meet any of the criteria listed above; or
-
For diagnosing malignant (accelerated phase) hypertension. Under accepted guidelines, malignant hypertension requires urgent hospital admission for appropriate investigation and treatment; or
-
For members with an irregular cardiac rhythm (e.g., atrial fibrillation). Blood pressure readings are inconsistent and unreliable when an irregular cardiac rhythm is present due to variances in pulse volume; or
-
For monitoring normal or borderline hypertensive blood pressure readings in the medical setting of members with documented evidence of end-organ damage (e.g., nephropathy, electrocardiographical changes, left ventricular hypertrophy, angina, myocardial infarction, cerebrovascular accident, transient ischemic attack) or cardiovascular risk factors (e.g., diabetes mellitus, smoking, hypercholesterolemia); or
-
For routine monitoring to establish the clinical diagnosis of hypertension or to evaluate the member's blood pressure responses to treatment; or
- Routine use before initiation of continuous positive airway pressure (CPAP) therapy (i.e., performance of ABPM prior to CPAP in persons who do not have any of the medically necessary indications for ABPM listed in section I).
-
-
Related Policies
Code | Code Description |
---|---|
Information in the [brackets] below has been added for clarification purposes. Codes requiring a 7th character are represented by "+": |
|
CPT codes covered if selection criteria are met: |
|
93784 | Ambulatory blood pressure monitoring, utilizing a system such as magnetic tape and/or computer disk, for 24 hours or longer; including recording, scanning analysis, interpretation and report |
93786 | recording only |
93788 | scanning analysis with report |
93790 | physician review with interpretation and report |
Other CPT codes related to the CPB: |
|
36251 | Selective catheter placement (first-order), main renal artery and any accessory renal artery(s) for renal angiography,including arterial puncture and catheter placement(s), fluoroscopy, contrast injections(s), image postprocessing, permanent recording of images, and radiological supervision and interpretation, including pressure gradient measurements when performed, and flush aortogram when performed; unilateral |
36252 | bilateral |
36253 | Superselective catheter placement (one or more second order or higher renal artery branches), renal artery and any accessory renal artery(s) for renal angiography,including arterial puncture and catheter placement(s), fluoroscopy, contrast injections(s), image postprocessing, permanent recording of images, and radiological supervision and interpretation, including pressure gradient measurements when performed, and flush aortogram when performed; unilateral |
36254 | bilateral |
80416 | Renal vein renin stimulation panel (e.g., captopril) |
80417 | Peripheral vein renin stimulation panel (e.g., captopril) |
84244 | Renin |
ICD-10 codes covered if selection criteria are met: |
|
D35.00 - D35.02 | Benign neoplasm of adrenal gland |
I10 | Hypertension [malignant only] |
I11.9 | Hypertensive heart disease without heart failure |
I15.0 - I16.2 | Secondary hypertension [malignant only] |
I20.8 | Other forms of angina pectoris [Angina decubitus] |
I95.0 - I95.9 | Hypotension |
R03.0 | Elevated blood-pressure reading, without diagnosis of hypertension |
R55 | Syncope and collapse |
ICD-10 codes not covered for indications listed in the CPB: |
|
E08.00 - E13.9 | Diabetes mellitus |
E78.00 - E78.01 | Pure and familial hypercholesterolemia |
E78.2 | Mixed hyperlipidemia |
F17.200 - F17.299 | Nicotine dependence |
I09.81 | Rheumatic heart failure (congestive) |
I21.01 - I25.2 | ST elevation (STEMI) and non-ST (NSTEMI) myocardial infarction |
I21.A1 | Myocardial infarction type 2 |
I21.A9 | Other myocardial infarction type |
I50.1 - I50.9 | Heart failure |
I51.7 | Cardiomegaly |
I65.01 - I67.9 | Occlusion and stenosis of precerebral arteries, not resulting in cerebral infarction |
M10.30 - M10.39 | Gout due to renal impairment |
N05.0 - N05.9 N17.1 - N17.2 |
Nephritis and nephropathy |
N17.0 - N17.9 | Acute kidney failure |
N18.1 - N18.9 | Chronic kidney disease (CKD) |
N19 | Unspecified kidney failure |
R03.1 | Nonspecific low blood pressure reading |
R94.31 | Abnormal electrocardiogram [ECG] [EKG] |
Z13.6 | Encounter for screening for cardiovascular disorders |
Z34.00 - Z34.93 | Encounter for supervision of normal pregnancy |
Background
Automated ambulatory blood pressure (BP) monitoring is an outpatient procedure using fully automated devices to measure ambulatory BP at frequent intervals during the day and night in an effort to determine the variability of a patient's BP due to environmental stresses and to aid in definitively establishing a diagnosis of hypertension before committing the patient to life-long antihypertensive therapy.
Continuous ambulatory blood pressure (CABP) monitoring, (also known as noninvasive blood pressure monitoring [NIBP], ambulatory blood pressure monitoring [ABPM] and self-measured blood pressure monitoring [SMBP]) is a noninvasive method of measuring blood pressure (BP) over a specified period of time. Monitoring is generally done for at least 24 hours, but can be up to a maximum of three days. This is a fully automated or semi-automated device consisting of a portable battery-operated monitor worn on the hip (attached to a belt or clothing) and connected to an inflatable blood pressure cuff. The cuff will inflate at pre-set intervals (usually every 15 to 30 minutes during the day and every 30 minutes to an hour at night). The BP is then measured and recorded in the monitor where it can be retrieved for interpretation. In addition to the automatic preset readings, the semi-automated monitor can also be activated to take additional readings such as when the individual is exerting herself/himself or has symptoms of dizziness or heart racing.
CABP monitoring is utilized to evaluate individuals who are suspected of having an elevated BP only in the physician’s office (known as white coat hypertension). It has also been proposed for use in monitoring hypotension and the effectiveness of medication. CABP is also purported as a method to predict cardiovascular morbidity or mortality related to left ventricular hypertrophy and may provide useful information regarding the BP in individuals who may have chronic kidney disease, diabetes or preeclampsia. In addition, it could potentially provide the resources to capture a drop greater than 10% in nightly BP, which is called "dipping." Non-dippers are individuals who have less than a 10% decrease in their nightly BP and potentially have a higher cardiovascular mortality rate.
Since treatment is rarely urgent in the absence of severe hypertension, the physician's diagnosis of hypertension should be substantiated first by repeated office readings by well-trained clinicians.
Patients with borderline hypertensive measurements in the office setting should have basic cardiovascular tests done. Those who have evidence of target-organ damage or other cardiovascular risk factors should receive non-pharmacological and/or pharmacological treatments without further investigation. Studies have unequivocally demonstrated that these patients have a significant risk of developing cardiovascular disease and will benefit from antihypertensive therapy. Patients with no evidence of target-organ damage and no risk factors should be classified by a trial of self-measured BP; drug treatment should be considered for patients with consistently elevated readings in this setting.
The U.S. Preventive Services Task Force (2015) recommends screening for high blood pressure in adults aged 18 years or older. The USPSTF recommends obtaining measurements outside of the clinical setting for diagnostic confirmation before starting treatment. The Task Force states that ambulatory blood pressure monitoring and home blood pressure monitoring may be used to confirm a diagnosis of hypertension after initial screening. The USPSTF found convincing evidence that ambulatory blood pressure monitoring is the best method for diagnosing hypertension. Although the criteria for establishing hypertension varied across studies, there was significant discordance between the office diagnosis of hypertension and 12- and 24-hour average blood pressures using ambulatory blood pressure monitoring, with significantly fewer patients requiring treatment based on ambulatory blood pressure monitoring. Elevated ambulatory systolic blood pressure was consistently and significantly associated with increased risk for fatal and nonfatal stroke and cardiovascular events, independent of office blood pressure. For these reasons, the USPSTF recommends ambulatory blood pressure monitoring as the reference standard for confirming the diagnosis of hypertension. The USPSTF states that home blood pressure monitoring using appropriate protocols is an alternative method of confirmation if ambulatory blood pressure monitoring is not available.
In a systematic review, Goyal and colleagues (2005) stated that "ambulatory blood pressure monitoring has established its use in the definition of white coat hypertension and monitoring of treatment of essential hypertension. Any role for ambulatory blood pressure monitoring in heart failure is not well defined .... Prospective controlled studies on the impact of treatments on circadian blood pressure profile in congestive heart failure patients are needed".
Sorof and Portman (2000) reviewed their experience using ambulatory BP monitoring in children referred to a hypertension clinic to determine the frequency of pediatric white coat hypertension (WCH), which was defined by 3 different diagnostic criteria:- mean 24-hour BP less than Task Force-defined 95th percentile,
- mean 24-hour BP less than 95th percentile from pediatric normative ambulatory BP monitoring data, and
- mean 24-hour BP less than ambulatory BP monitoring 95th percentile and BP load (percentage of BP readings during 24-hour period exceeding the 95th percentile) less than 25 %.
Clinic BP values were available in 67 otherwise healthy children who underwent ambulatory BP monitoring; 51 had confirmed clinic hypertension by Task Force criteria. Frequency of WCH in these 51 patients with the stated criteria was 53 %, 45 %, and 22 %, respectively. Elevated BP load was found in 52 % (12/23) of patients with normal mean BP. The authors concluded that these findings suggested that many children referred for casual BP elevation have WCH even by strict diagnostic criteria. Ambulatory BP monitoring may help differentiate WCH from persistent hypertension, thereby avoiding unnecessary diagnostic evaluation and identifying children most likely to benefit from early intervention.
Stergiou et al (2004) stated that office and out-of-office BP measurements are being used for the diagnosis of hypertension in children and adolescents. The U.S. National Heart, Lung, and Blood Institute have recently presented a new classification of BP. On the basis of office measurements the 90th, 95th and 99th percentile for gender, age and height are used to classify children and adolescents as normotensive, pre-hypertensive and stage-1 or stage-2 hypertensive. Although auscultation using a standard mercury sphygmomanometer remains the recommended method, accumulating evidence suggests that ambulatory BP monitoring is useful for the detection of WCH and the prediction of target organ damage in children and adolescents. Studies have shown ambulatory BP to be more reproducible than office measurements and normative tables for ambulatory measurements have been developed from cross-sectional studies in children and adolescents. In regard to home measurements in children, there are limited data from small trials showing lower BP levels than daytime ambulatory BP. The authors concluded that ambulatory BP monitoring is already finding a role as a supplementary source of information in children and adolescents, whereas at present home measurements should not be used for decision making in this population.
In a review and meta-analysis, Bliziotis et al (2012) examined the association of home BP measurements with target organ damage. A PubMed and Cochrane Library search (1950 to 2011) revealed 23 studies reporting comparative data of home BP versus ambulatory and/or office measurements in terms of their association with several indices of target organ damage. Correlation coefficients were pooled by random-effects model meta-analysis. A total of 14 studies (n = 2,485) assessing echocardiographic left ventricular mass index (LVMI) showed similar correlations with home (coefficients r = 0.46/0.28, systolic/diastolic) as with ambulatory BP (0.37/0.26, p = NS for difference versus home BP), and superior to office measurements (r = 0.23/0.19, p < 0.001/0.009 for difference versus home BP). Four methodologically heterogeneous studies assessing the glomerular filtration rate (n = 609) could not be pooled or lead to a concrete result. Four studies assessing carotid intima-media thickness (n = 1,222), 3 assessing pulse wave velocity (n = 720) and 2 assessing urinary protein excretion (n = 156) showed no difference in pooled correlation coefficients with home versus office BP measurements. With all the measurement methods, systolic blood pressure (SBP) was more closely associated with target organ damage than diastolic blood pressure (DBP). The authors concluded that these data suggested that home BP is as good as ambulatory monitoring and superior to office measurements in regard to their association with pre-clinical organ damage assessed by echocardiographic LVMI. They stated that more research is needed to evaluate the relationship of home BP with other indices of target organ damage.
Swartz et al (2008) determined the cost-effectiveness of ambulatory BP monitoring in the initial evaluation of stage 1 hypertension. Retrospective chart review of data for children referred to Texas Children's Hospital hypertension clinic between January 2005 and August 2006 was performed. These investigators compared the costs of standard evaluations versus the initial use of ambulatory BP monitoring for children with clinic BP measurements suggesting stage 1 hypertension. Charges for clinic visits, laboratory tests, and imaging were obtained from the Texas Children's Hospital billing department. A total of 267 children were referred – 139 children did not receive ambulatory BP monitoring; 54 met clinical indications for ambulatory BP monitoring but did not receive it because it was not a covered expense (44 children) or the family refused the study (10 children); 126 children received clinically indicated ambulatory BP monitoring, paid for either through insurance or by the family. Fifty-eight children (46 %) had confirmed white-coat hypertension, 62 (49 %) stage 1 hypertension, and 6 (5 %) stage 2 hypertension. With the observed prevalence of WCH, initial ambulatory BP monitoring use yielded net savings after evaluation of 3 patients, with projected savings of $2.4 million per 1,000 patients. The authors concluded that ambulatory BP monitoring in the initial evaluation of suspected childhood hypertension is highly cost-effective. Awareness of cost saving potential may increase the availability of ambulatory BP monitoring for evaluation of new-onset hypertension.
Muxfeldt et al (2012) stated that resistant hypertension is defined as uncontrolled office BP, despite the use of greater than or equal to 3 anti-hypertensive drugs. Ambulatory BP monitoring (ABPM) is mandatory to diagnose 2 different groups, those with true and white-coat resistant hypertension. Patients are found to change categories between controlled/uncontrolled ambulatory pressures without changing their office BP. In this way, ABPM should be periodically repeated. The aim of this study was to evaluate the most appropriate time interval to repeat ABPM to assure sustained BP control in patients with white-coat resistant hypertension. This prospective study enrolled 198 patients (69 % women; mean age of 68.9 +/- 9.9 years) diagnosed as white-coat resistant hypertension on ABPM. Patients were submitted to a second confirmatory examination 3 months later and repeated twice at 6-month intervals. Statistical analyses included Bland-Altman repeatability coefficients and multi-variate logistic regression. Mean office BP was 163 ± 20/84 ± 17 mm Hg, and mean 24-hour BP was 118 ± 8/66 ± 7 mm Hg. White-coat resistant hypertension diagnosis presented a moderate reproducibility and was confirmed in 144 patients after 3 months. In the 3rd and 4th ABPMs, 74 % and 79 % of patients sustained the diagnosis. In multi-variate regression, a daytime systolic blood pressure less than or equal to 115 mm Hg in the confirmatory ABPM triplicated the chance of white-coat resistant hypertension status persistence after 1 year. The authors concluded that a confirmatory ABPM is necessary after 3 months of the 1st white-coat-resistant hypertension diagnosis, and the procedure should be repeated at 6-month intervals, except in patients with daytime systolic blood pressure less than or equal to 115 mm Hg, in whom it may be repeated annually.
Vollebregt and colleagues (2013) stated that it is not known whether automated devices for measuring BP perform better than conventional sphygmomanometry in predicting preeclampsia. In a prospective, observational, cohort study, these investigators compared 2 different automated devices with conventional sphygmomanometry for their association with development of preeclampsia or gestational hypertension. A total of 289 healthy normotensive women of whom 235 were nulliparous and 44 parous with preeclampsia in a previous pregnancy were include in this study. At 8 to 11 weeks of pregnancy, BP was measured with 2 different automated devices (continuous finger arterial pressure waveform registration and ABPM) and with conventional sphygmomanometry. Main outcome measures were preeclampsia and gestational hypertension. Blood pressure in the 1st trimester, as measured with all 3 methods, was significantly higher in women who developed preeclampsia or gestational hypertension. After adjustment for previous preeclampsia, the point estimate of the odds ratios for association with later preeclampsia for both automated devices were comparable and higher than for conventional sphygmomanometry; however, differences were not statistically significant. The odds ratio (95 % confidence intervals) for every 1 mmHg pressure increase of mean arterial pressure was 1.08 (1.02 to 1.15) for sphygmomanometry, 1.17 (1.09 to 1.27) for finger arterial pressure waveform registration, and 1.17 (1.07 to 1.27) for ABPM. Results were comparable if preeclampsia and gestational hypertension were analyzed together. The authors concluded that BP in the 1st trimester was associated with the development of hypertensive disorders of pregnancy; however, no significant differences were found between measurements by automatic devices including ABPM compared with conventional sphygmomanometry.
O’Brien and Dolan (2016) reviewed the current recommendations for ABPM and the use of ABPM in assessing treatment. These investigators reviewed current international guidelines and undertook a critical review of evidence supporting the clinical use of ABPM in effectively managing anti-hypertensive drug treatment. Current guidelines emphasize the diagnostic superiority of ABPM, mainly from the ability of the technique to identify sustained hypertension by allowing for the exclusion of white-coat hypertension and by demonstrating the presence of masked hypertension; ABPM also offers diagnostic insights into nocturnal patterns of BP, such as dipping and non-dipping, reverse dipping, and excessive dipping, and the presence of nocturnal hypertension; although less attention is given to the nocturnal behavior of BP in clinical practice, the nocturnal patterns of BP have particular relevance in assessing the response to BP-lowering medication. Surprisingly, although the current guidelines give detailed recommendations on the diagnostic potential and use of ABPM, there are scant recommendations on the benefits and application of the technique for the initiation of BP-lowering therapy in clinical practice and virtually no recommendations on how it might be used to assess the effectiveness of drug treatment. The authors concluded that i view of a deficiency in the literature on the role of ABPM in assess the effectiveness of drug treatment, they put forward proposals to correct this deficiency and guide the prescribing physician on the most appropriate drug administration and dosage over time.
Routine Use Before Initiation of Continuous Positive Airway Pressure (CPAP) Therapy
Castro-Grattoni and colleagues (2017) stated that the reduction in BP with continuous positive airway pressure (CPAP) is modest and highly variable. These researchers identified the variables that predict BP response to CPAP; 24-hour ABPM, C-reactive protein (CRP), leptin, adiponectin and 24-hour urinary catecholamine were measured before and after 6 months of CPAP in obstructive sleep apnea (OSA) patients. A total of 88 middle-aged, obese male patients with severe OSA (median apnea-hypopnea index [AHI] of 42 events/hour) were included; 28.4 % had hypertension; 62 patients finished the study, and 60 were analyzed. The daytime DBP (-2 mmHg) and norepinephrine (-109.5 nmol/day) were reduced after CPAP, but no changes in the 24-hour BP, night-time BP, dopamine, epinephrine, CRP, leptin or adiponectin were detected. The nocturnal normotension was associated with an increased night-time-BP (+4 mmHg) after CPAP, whereas nocturnal hypertension was associated with a reduction of 24-hour BP (-3 mmHg). A multi-variate linear regression model showed differential night-time BP changes after CPAP. Specifically, low night-time heart rate (HR; less than 68 bpm) and BP dipper profile were associated with increased night-time BP and new diagnosis of nocturnal hypertension. The authors concluded that these findings suggested that nocturnal hypertension, circadian BP pattern and night-time HR could be clinical predictors of BP response to CPAP and support the usefulness of 24-hour ABPM for OSA patients before treatment initiation. Moreover, they stated that these findings need to be confirmed in further studies.
Accuracy of Automated BP Measurements in Patients with Atrial Fibrillation
Clark and colleagues (2019) noted that atrial fibrillation (AF) affects approximately 3 % of the general population and is twice as common with hypertension. Validation protocols for automated sphygmomanometers exclude people with AF, raising concerns over accuracy of hypertension diagnosis or management, using out-of-office BP monitoring, in the presence of AF. Some devices include algorithms to detect AF; a feature open to misinterpretation as offering accurate BP measurement with AF. These researchers examined the accuracy of automated devices, with or without AF detection, for measuring BP. They searched Medline and Embase to October 2018 for studies comparing automated BP measurement devices to a standard mercury sphygmomanometer contemporaneously. Data were extracted by 2 reviewers. Mean BP differences between devices and mercury were calculated, where not reported and compared; meta-analyses were undertaken where possible. These investigators included 13 studies reporting 14 devices. Mean systolic and diastolic BP differences from mercury ranged from -3.1 to + 6.1/-4.6 to +9.0 mmHg. Considerable heterogeneity existed between devices (I2: 80 to 90 %). Devices with AF detection algorithms appeared no more accurate for BP measurement with AF than other devices. A previous review concluded that oscillometric devices were accurate for systolic but not diastolic BP measurement in AF. The findings of this study did not support that conclusion. As a consequence of heterogeneity between devices, they should be evaluated on individual performance. The authors found no evidence that devices with AF detection measured BP more accurately in AF than other devices. These researchers stated that more home or ambulatory automated BP monitors require validation in populations with AF.Comparison Between Automated Office Blood Pressure Measurements and Manual Office Blood Pressure Measurements
Bo et al (2021) stated that automated office BP (AOBP) measurements may provide more accurate estimation of BP than manual office BP (MOBP) measurements. In a systematic review, these investigators examined the diagnostic performance of AOBP and MOBP using ABPM as reference. Several databases including Medline, Embase, Scopus, and China Academic Journals were searched. Data were extracted, double-checked by 2 investigators, and were analyzed using a random effects model. A total of 26 observational studies were included. The mean systolic/diastolic BP obtained by AOBP was not significantly different from that obtained by ABPM. The sensitivity and specificity of AOBP to detect elevated BP were approximately 70 %. Fewer participants had white-coat hypertension on AOBP measurement than on MOBP measurement (7 % versus 14 %); however, about 13 % had masked hypertension on AOBP measurement. The width of the limit of agreement comparing AOBP and ABPM; and MOBP and ABPM was comparable. The authors concluded that AOBP may reduce the rate of the observed white-coat effect but undermined masked hypertension. The current recommendation, however, is limited by the absence of high-quality studies and the high heterogeneity of these findings. These researchers stated that more high-quality studies using different AOBP machines and in different population are needed.
Viera et al (2021) noted that office BP measurements are not the most accurate method to diagnose hypertension. Home BP monitoring (HBPM) and 24-hour ABPM are out-of-office alternatives, and ABPM is considered the reference standard for BP assessment. In a systematic review, these investigators examined the accuracy of oscillometric office and home BP measurement methods for correctly classifying adults as having hypertension, defined using ABPM. Data sources included PubMed, Cochrane Library, Embase, ClinicalTrials.gov, and DARE databases and the American Heart Association (AHA) website (from inception to April 2021) were searched, along with reference lists from retrieved articles. Two authors independently abstracted raw data and evaluated methodological quality; a 3rd author resolved disputes as needed. Random effects summary sensitivity, specificity, and likelihood ratios (LRs) were calculated for BP measurement methods for the diagnosis of hypertension. ABPM (24-hour mean BP of greater than or equal to 130/80 mm Hg or mean BP while awake of greater than or equal to 135/85 mm Hg) was considered the reference standard. A total of 12 cross-sectional studies (n = 6,877) that compared conventional oscillometric office BP measurements to mean BP during 24-hour ABPM and 6 studies (n = 2,049) that compared mean BP on HBPM to mean BP during 24-hour ABPM were included (range of 117 to 2,209 participants per analysis); 2 of these studies (n = 3,040) used consecutive samples. The overall prevalence of hypertension identified by 24-hour ABPM was 49 % (95 % CI: 39 % to 60 %) in the pooled studies that evaluated office measures and 54 % (95 % CI: 39 % to 69 %) in studies that evaluated HBPM. All included studies assessed sensitivity and specificity at the office BP threshold of 140/90 mm Hg and the home BP threshold of 135/85 mm Hg. Conventional office oscillometric measurement (1 to 5 measurements in a single visit with BP of greater than or equal to 140/90 mm Hg) had a sensitivity of 51 % (95 % CI: 36 % to 67 %), specificity of 88 % (95 % CI: 80 % to 96 %), positive LR of 4.2 (95 % CI: 2.5 to 6.0), and negative LR of 0.56 (95 % CI: 0.42 to 0.69). Mean BP with HBPM (with BP of greater than or equal to 135/85 mm Hg) had a sensitivity of 75 % (95 % CI: 65 % to 86 %), specificity of 76 % (95 % CI: 65 % to 86 %), positive LR of 3.1 (95 % CI: 2.2 to 4.0), and negative LR of 0.33 (95 % CI: 0.20 to 0.47). Two studies (1 with a consecutive sample) that compared unattended automated mean office BP (with BP of greater than or equal to 135/85 mm Hg) with 24-hour ABPM had sensitivity ranging from 48 % to 51 % and specificity ranging from 80 % to 91 %. One study that compared attended automated mean office BP (with BP of greater than or equal to 140/90 mm Hg) with 24-hour ABPM had a sensitivity of 87.6 % (95 % CI: 83 % to 92%) and specificity of 24.1 % (95 % CI: 16 % to 32 %). The authors concluded that office measurements of BP may not be accurate enough to rule in or rule out hypertension; HBPM may be helpful to confirm a diagnosis. These investigators stated that when there is uncertainty regarding threshold values or when office and HBPM are not in agreement, 24-hour ABPM should be considered to establish the diagnosis.
Smartphone Application-Assisted Home Blood Pressure Monitoring Compared with Office and Ambulatory Blood Pressure Monitoring in Patients with Hypertension
Groenland et al (2022) noted that the development of automated, smartphone application (app)-assisted HBPM allows for standardized measurement of BP at home. In an open, randomized, 5-way cross-over study, these researchers examined the (diagnostic) agreement between app-assisted HBPM, automated office BP (OBP), and the reference standard 24-hour ABPM. Patients diagnosed with hypertension were randomized to 1 of 10 clusters, each containing 5 BP measurement methods (ABPM, HBPM, attended OBP, unattended OBP, and unattended 30-min BP) in different order. A total of 113 patients were included. The average 24-hour ABPM was 126 ± 11 / 73 ± 8 mm Hg compared with 141 ± 14 / 82 ± 10 mm Hg with app-assisted HBPM, 134 ± 13 / 80 ± 9 mm Hg with unattended 30-min BP, 137 ± 16 / 81 ± 11 mm Hg with attended OBP, and 135 ± 15 / 81 ± 10 mm Hg with unattended OBP monitoring. Diagnostic agreement between app-assisted HBPM and 24-hour ABPM for diagnosing sustained (OBP greater than 140/90 mm Hg and ABPM of greater than or equal to 130/80 mm Hg or HBPM of greater than or equal to 135/85 mm Hg), white-coat (OBP of greater than or equal to 140/90 mm Hg and ABPM of less than 130/80 mm Hg or HBPM of less than 135/85 mm Hg), and masked hypertension (OBP of less than 140/90 mm Hg and ABPM of greater than or equal to 130/80 mm Hg or HBPM of greater than or equal to 135/85 mm Hg) was fair-to-moderate (κ statistics ranging from 0.34 to 0.40). App-assisted HBPM had high sensitivities (78 % to 91 %) and negative predictive values (90 % to 97 %) for diagnosing sustained and masked hypertension. The authors concluded that this study showed a considerable (diagnostic) disagreement between app-assisted HBPM and ABPM. They noted that the high sensitivity and negative predictive value (NPV) for diagnosing sustained and masked hypertension suggested that app-assisted HBPM may be suitable for screening on these hypertension phenotypes, but not a replacement of, ABPM.
The authors stated that this study had 2 main drawbacks. First, since the majority of the population was prescribed anti-hypertensive medication, the findings may not be generalizable to individuals (in primary care) who have not yet been prescribed anti-hypertensive medications, in whom BP variability was likely to be greater. Second, the cross-over design of this study did not allow the performance of HBPM to be evaluated based on the occurrence of clinical outcomes, which is considered an important aspect in determining the best BP measurement method.
Appendix
Blood Pressure Levels by Age and Height Percentile: Blood Pressure Levels for Boys and Girls by Age and Height Percentile
References
The above policy is based on the following references:
- American College of Physicians. Automated ambulatory blood pressure and self-measured blood pressure monitoring devices: Their role in the diagnosis and management of hypertension. Ann Intern Med. 1993;118(11):889-892.
- Appel L, Robinson K, Guallar E. Utility of blood pressure monitoring outside of the clinic setting. Evidence Report/Technology Assessment 63. Rockville, MD: Agency for Healthcare Research and Quality (AHRQ); 2002.
- Appel L, Stason WB. Ambulatory blood pressure monitoring and blood pressure self-measurement in the diagnosis and management of hypertension. Ann Intern Med. 1993;118(11):867-882.
- Banegas JR, Ruilope LM, de la Sierra A, et al. Relationship between clinic and ambulatory blood-pressure measurements and mortality. N Engl J Med. 2018;378(16):1509-1520.
- Bergel E, Carroli G, Althabe F. Ambulatory versus conventional methods for monitoring blood pressure during pregnancy. Cochrane Database Syst Rev. 2002;(2):CD001231.
- Bisset AF. Ambulatory versus conventional blood pressure monitoring. STEER: Succint and Timely Evaluated Evidence Reviews. Bazian Ltd., eds. London, UK: Wessex Institute for Health Research and Development, University of Southampton; 2001;1(20):1-8.
- Bliziotis IA, Destounis A, Stergiou GS. Home versus ambulatory and office blood pressure in predicting target organ damage in hypertension: A systematic review and meta-analysis. J Hypertens. 2012;30(7):1289-1299.
- Bo Y, Kwok K-O, Chu KKY, et al. Comparison between automated office blood pressure measurements and manual office blood pressure measurements -- implications in individual patients: A systematic review and meta-analysis. Hypertens Rep. 2021;23(1):4.
- Brown MA, Mangos G, Davis G, Homer C. The natural history of white coat hypertension during pregnancy. BJOG. 2005;112(5):601-606.
- Campbell P, Ghuman N, Wakefield D, et al. Long-term reproducibility of ambulatory blood pressure is superior to office blood pressure in the very elderly. J Hum Hypertens. 2010;24(11):749-754.
- Canadian Coordinating Office of Health Technology Assessment (CCOHTA). 24-hour ambulatory blood pressure monitoring. Pre-assessment No. 15. Ottawa, ON: CCOHTA; January 2003.
- Carek P, Carson DS, Cooke CE, Weart CW. Clinical implications of white coat hypertension. Am Fam Phys. 1995;52(1):163-168.
- Castro-Grattoni AL, Torres G, Martínez-Alonso M, et al. Blood pressure response to CPAP treatment in subjects with obstructive sleep apnoea: The predictive value of 24-h ambulatory blood pressure monitoring. Eur Respir J. 2017;50(4).
- Chavanu K, Merkel J, Quan AM. Role of ambulatory blood pressure monitoring in the management of hypertension. Am J Health Syst Pharm. 2008;65(3):209-218.
- Clark CE, McDonagh STJ, McManus RJ. Accuracy of automated blood pressure measurements in the presence of atrial fibrillation: Systematic review and meta-analysis. J Hum Hypertens. 2019;33(5):352-364.
- Cloutier L, Daskalopoulou SS, Padwal RS, et al. A new algorithm for the diagnosis of hypertension in Canada. Can J Cardiol. 2015;31(5):620-630.
- Ernst ME, Bergus GR. Ambulatory blood pressure monitoring. South Med J. 2003;96(6):563-568.
- Gijon-Conde T, Gorostidi M, Banegas JR, et al. Position statement on ambulatory blood pressure monitoring (ABPM) by the Spanish Society of Hypertension (2019). Hipertens Riesgo Vasc. 2019;36(4):199-212.
- Goyal D, Macfadyen RJ, Watson RD, Lip GY. Ambulatory blood pressure monitoring in heart failure: A systematic review. Eur J Heart Fail. 2005;7(2):149-156.
- Graves JW, Sheps SG. Does evidence-based medicine suggest that physicians should not be measuring blood pressure in the hypertensive patient? Am J Hypertens. 2004;17(4):354-360.
- Groenland EH, Vendeville JPAC, Bemelmans RHH, et al. Smartphone application-assisted home blood pressure monitoring compared with office and ambulatory blood pressure monitoring in patients with hypertension: The AMUSE-BP Study. Hypertension. 2022;79(10):2373-2382.
- Hemmelgarn BR, McAlister FA, Grover S, et al; Canadian Hypertension Education Program. The 2006 Canadian Hypertension Education Program recommendations for the management of hypertension: Part I--Blood pressure measurement, diagnosis and assessment of risk. Can J Cardiol. 2006;22(7):573-581.
- Institute for Clinical Systems Integration (ICSI). Hypertension diagnosis and treatment. ICSI Health Care Guidelines No. G15. Bloomington, MN: Institute for Clinical Systems Integration; February 1999.
- Jegatheswaran J, Ruzicka M, Hiremath S, Edwards C. Are automated blood pressure monitors comparable to ambulatory blood pressure monitors? A systematic review and meta-analysis. Can J Cardiol. 2017;33(5):644-652.
- Macumber I. Ambulatory blood pressure monitoring in children and adolescents: A review of recent literature and new guidelines. Curr Hypertens Rep. 2017;19(12):96.
- Magee LA, Pels A, Helewa M, et al; Hypertension Guideline Committee. Diagnosis of hypertensive disorders of pregnancy and classification of blood pressure measurements. In: Diagnosis, evaluation, and management of the hypertensive disorders of pregnancy: Executive summary. J Obstet Gynaecol Can. 2014;36(5):418-425.
- Mallion JM, Baguet JP, Mancia G. European Society of Hypertension Scientific Newsletter: Clinical value of ambulatory blood pressure monitoring. J Hypertens. 2006;24(11):2327-2330.
- Mengden T, Chamontin B, Phong Chau N, et al. User procedure for self-measurement of blood pressure. First International Consensus Conference on Self Blood Pressure Measurement. Blood Press Monit. 2000;5(2):111-129.
- Muxfeldt ES, Fiszman R, de Souza F, et al. Appropriate time interval to repeat ambulatory blood pressure monitoring in patients with white-coat resistant hypertension. Hypertension. 2012;59(2):384-389.
- Myers MG, Valdivieso M, Kiss A. Use of automated office blood pressure measurement to reduce the white coat response. J Hypertens. 2009;27(2):280-286.
- National Institute for Clinical Excellence (NICE). Management of hypertension in adults in primary care. Clinical Guideline 18. London, UK: NICE; 2004.
- No authors listed. National High Blood Pressure Education Program Working Group Report on Ambulatory Blood Pressure Monitoring. Arch Intern Med. 1990;150(11):2270-2280.
- No authors listed. The Fifth Report of the Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure (JNC V). Arch Intern Med. 1993;153(2):154-183.
- Norderhaug PI. Ambulatory blood pressure measurement. A review of international studies. SMM-Report 4/2000. Oslo, Norway: Norwegian Knowledge Centre for the Health Services (NOKC); 2000.
- Nordmann A, Frach B, Walker T, et al. Comparison of self-reported home blood pressure measurements with automatically stored values and ambulatory blood pressure. Blood Press. 2000;9(4):200-2005.
- O'Brien E, Beevers G, Lip GY. ABC of hypertension. Blood pressure measurement. Part III-automated sphygmomanometry: Ambulatory blood pressure measurement. BMJ. 2001;322(7294):1110-1114.
- O'Brien E, Dolan E. Ambulatory blood pressure monitoring for the effective management of antihypertensive drug treatment. Clin Ther. 2016;38(10):2142-2151.
- Piper MA, Evans CV, Burda BU, et al. Screening for High Blood Pressure in Adults: A Systematic Evidence Review for the U.S. Preventive Services Task Force. Rockville, MD: Agency for Healthcare Research and Quality; December 2014.
- Price D. The hypertensive patient in family practice. J Am Board Fam Pract. 1994;7(5):403-416.
- Quinn RR, Hemmelgarn BR, Padwal RS, et al; Canadian Hypertension Education Program. The 2010 Canadian Hypertension Education Program recommendations for the management of hypertension: Part I - blood pressure measurement, diagnosis and assessment of risk. Can J Cardiol. 2010;26(5):241-248.
- Satoh M, Maeda T, Hoshide S, Ohkubo T. Is antihypertensive treatment based on home blood pressure recommended rather than that based on office blood pressure in adults with essential hypertension? (meta-analysis). Hypertens Res. 2019;42(6):807-816.
- Scottish Intercollegiate Guidelines Network (SIGN). Hypertension in older people. A national clinical guideline. SIGN Publication No. 49. Edinburgh, Scotland: SIGN; 2001.
- Shapiro A, Karschner JK, Glunk DJ, Barnhill BM. Clinical use of ambulatory blood pressure monitoring. Arch Fam Med. 1995;4(8):691-696.
- Sheps S, Clement DL, Pickering TG, et al. Ambulatory blood pressure monitoring. J Am College Cardiol. 1994;23(6):1511-1513.
- Siu AL; U.S. Preventive Services Task Force. Screening for high blood pressure in adults: U.S. Preventive Services Task Force recommendation statement. Ann Intern Med. 2015;163(10):778-786.
- Sorof JM, Portman RJ. White coat hypertension in children with elevated casual blood pressure. J Pediatr. 2000;137(4):493-497.
- Staessen JA, O'Brien ET, Thijs L, et al. Modern approaches to blood pressure measurement. Occup Environ Med. 2000;57(8):510-520.
- Staessen JA, Thijs L. Development of diagnostic thresholds for automated self-measurement of blood pressure in adults. First International Consensus Conference on Blood Pressure Self-Measurement. Blood Press Monit. 2000;5(2):101-109.
- Stergiou G, Stambolliu E, Bountzona I, et al. Home blood pressure monitoring in children and adolescents: Systematic review of evidence on clinical utility. Curr Hypertens Rep. 2019;21(8):64.
- Stergiou GS, Alamara CV, Vazeou A, Stefanidis CJ. Office and out-of-office blood pressure measurement in children and adolescents. Blood Press Monit. 2004;9(6):293-296.
- Sutherland J, Castle C, Friedman R. Hypertension: Current management strategies. J Am Board Fam Pract. 1994;7(3):202-217.
- Swartz SJ, Srivaths PR, Croix B, Feig DI. Cost-effectiveness of ambulatory blood pressure monitoring in the initial evaluation of hypertension in children. Pediatrics. 2008;122(6):1177-1181.
- Tice JA. Utility of ambulatory blood pressure monitoring. Technology Assessment. San Francisco, CA: California Technology Assessment Forum (CTAF); October 20, 2004.
- U.S. Preventive Services Task Force. Screening for hypertension. In Guide to Clinical Preventive Services. 2nd ed. Baltimore, MD: Williams & Wilkins; 1996:39-51.
- Urbina E, Alpert B, Flynn J, et al; American Heart Association Atherosclerosis, Hypertension, and Obesity in Youth Committee. Ambulatory blood pressure monitoring in children and adolescents: Recommendations for standard assessment: A scientific statement from the American Heart Association Atherosclerosis, Hypertension, and Obesity in Youth Committee of the council on cardiovascular disease in the young and the council for high blood pressure research. Hypertension. 2008;52(3):433-451.
- Viera AJ, Yano Y, Lin F-C, et al. Does this adult patient have hypertension?: The rational clinical examination systematic review. JAMA. 2021;326(4):339-347.
- Vollebregt KC, Boer K, Van Der Post JA, Wolf H. Association of three different techniques to measure blood pressure in the first trimester with the development of hypertensive disorders of pregnancy. Acta Obstet Gynecol Scand. 2013;92(1):53-60.
- White WB. Ambulatory blood pressure monitoring as an investigative tool for characterizing resistant hypertension and its rational treatment. J Clin Hypertens (Greenwich). 2007;9(1 Suppl 1):25-30.
- Zachariah P, Sheps SG, Smith RL. Clinical use of home and ambulatory blood pressure monitoring. Mayo Clin Proc. 1989;64(11):1436-1446.