Non-Invasive Fetal Membranes Rupture Tests

Number: 0757

Table Of Contents

Policy
Applicable CPT / HCPCS / ICD-10 Codes
Background
References


Policy

Scope of Policy

This Clinical Policy Bulletin addresses selected non-invasive tests for premature rupture of membranes.

  1. Experimental and Investigational

    Aetna considers the following interventions experimental and investigational because the effectiveness of these approaches has not been established:

    1. Biobeat Monitoring Platform for monitoring rupture of membranes (ROM)
    2. Evaluation of vaginal microbiome profiles for detecting preterm ROM
    3. Fetal membrane imaging (e.g., fusion MRI imaging, magnetic resonance elastography, optical coherence elastography, optical coherence tomography, shear wave elastography, and ultrasonography) for detecting preterm ROM
    4. Functional placental magnetic resonance imaging for evaluation of infection/inflammation in women with preterm premature ROM
    5. Non-invasive fetal membranes rupture tests (e.g., Actim PROM, AmniSure ROM, Chorioquick, and the ROM Plus Fetal Membranes Rupture Test) for detecting preterm ROM and all other indications.

Table:

CPT Codes / HCPCS Codes / ICD-10 Codes

Code Code Description

Information in the [brackets] below has been added for clarification purposes.   Codes requiring a 7th character are represented by "+":

CPT codes not covered for indications listed in the CPB:

Evaluation of vaginal microbiome profiles, fusion MRI imaging, magnetic resonance elastography, optical coherence elastography, optical coherence tomography or shear wave elastography - no specific codes:

0066U Placental alpha-micro globulin-1 (PAMG-1), immunoassay with direct optical observation, cervico-vaginal fluid, each specimen
76391 Magnetic resonance (eg, vibration) elastography
76811 Ultrasound, pregnant uterus, real time with image documentation, fetal and maternal evaluation plus detailed fetal anatomic examination, transabdominal approach; single or first gestation
76812     each additional gestation (List separately in addition to code for primary procedure)
76981 Ultrasound, elastography; parenchyma (eg, organ)
76982 - 76983 Ultrasound, elastography
84112 Evaluation of cervicovaginal fluid for specific amniotic fluid protein(s) (eg, placental alpha microglobulin-1 [PAMG-1], placental protein 12 [PP12], alpha-fetoprotein), qualitative, each specimen

HCPCS codes not covered for indications listed in the CPB:

Biobeat Monitoring Platform - no specific code

ICD-10 codes not covered for indications listed in the CPB (not all-inclusive):

O00.00 - O08.9, O10.011 - O26.93
O29.011 - O30.019, O30.031 - O35.6xx+
O36.011+ - O9a.53
Complications of pregnancy, childbirth, and the puerperium
O42.00 - O42.92 Premature rupture of membranes
O09.00 - O09.93
Z34.00 - Z34.93
Supervision of pregnancy
Z36. 89 Encounter for other specified antenatal screening [antepartum screening with broth enrichment for group B streptococcal infection in pregnant women at 35 to 37 weeks gestation]

Functional placental magnetic resonance imaging:

CPT codes not covered for indications listed in the CPB:

74712 Magnetic resonance (eg, proton) imaging, fetal, including placental and maternal pelvic imaging when performed; single or first gestation
74713      each additional gestation

ICD-10 codes not covered for indications listed in the CPB (not all-inclusive):

O41.1010 - O41.1499 Infection of amniotic sac and membranes
O42.00 - O42.92 Premature rupture of membranes

Background

During pregnancy, the fetal membrane protects the developing fetus and its surrounding amniotic fluid from infection. Tearing or rupture of membranes (ROM) normally occurs during labor. Premature rupture of membranes (PROM) is defined as rupture of membranes before the onset of labor.  Membrane rupture that occurs before 37 weeks of gestation is referred to as preterm PROM (PPROM).  Premature rupture of membranes complicates approximately 8 % of pregnancies and is generally followed by the prompt onset of spontaneous labor and delivery. The most significant maternal risk of term PROM is intra-uterine infection, a risk that increases with the duration of membrane rupture.  Fetal risks associated with term PROM include umbilical cord compression and ascending infection.  Preterm PROM complicates only 2 % of pregnancies but is associated with 40% of preterm deliveries and can result in significant neonatal morbidity and mortality.  The 3 causes of neonatal death associated with PPROM are prematurity, sepsis and pulmonary hypoplasia (RCOG, 2006; ACOG, 2007). 

Several risk factors for PPROM have been identified, including intra-amniotic infection, low socioeconomic status, low body mass index, second and third-trimester bleeding, nutritional deficiencies of copper and ascorbic acid, connective tissue disorders (e.g., Ehlers-Danlos syndrome), cigarette smoking, cervical conization or cerclage, pulmonary disease during the pregnancy, uterine over-distention, as well as amniocentesis.  The risk of recurrence for PPROM is between 16 % and 32 %.  Risk factors for PROM include previous preterm birth (especially if the cause was PROM), short cervical length (less than 25 mm) during the second trimester, and preterm labor or symptomatic contractions in the current pregnancy.  In addition, PROM can occur without any identifiable risk factor. 

According to the American College of Obstetricians and Gynecologists (ACOG) Practice Bulletin Premature Rupture of Membranes (2007), and the Royal College of Obstetricians and Gynaecologists (RCOG) Guideline Preterm Prelabour Rupture of Membranes (2006), the diagnosis of PROM is based primarily on the patient's history and physical examination.  Patients often report a sudden gush of fluid or continued leakage of fluid. Sterile speculum examination provides a visual inspection of fluid and an opportunity to inspect for cervicitis and umbilical cord or fetal prolapse, cervical dilation and effacement, and to obtain cultures as appropriate.  Digital cervical examinations are avoided due to the increase risk of infection and they add little additional information to the speculum examination (unless the patient is in active labor or imminent delivery is planned).  

Diagnostic methods using nitrazine paper and determination of ferning (arborization) have sensitivities approaching 90 %. The nitrazine test involves placing small amounts (a drop or two) of vaginal fluid onto paper strips prepared with Nitrazine dye. A chemical reaction occurs and the strips change color, indicating the pH of the vaginal fluid. It is designed to confirm an alkaline pH in cervicovaginal secretions (pH of vaginal secretions is generally 4.5–6.0, whereas amniotic fluid usually has a pH of 7.1–7.3). For the fern test, fluid from the posterior vaginal fornix is swabbed onto a glass slide and allowed to dry for at least 10 minutes. The slide is then reviewed under a microscope; amniotic fluid produces a delicate ferning pattern, in contrast to the thick and wide arborization pattern of dried cervical mucus.  

The pH of vaginal secretions is generally 4.5 to 6.0, whereas amniotic fluid usually has a pH of 7.1 to 7.3; however, false-positive results may occur as the result of contamination with blood or semen, alkaline antiseptics, or bacterial vaginosis and false-negative results can occur with prolonged leakage and minimal residual fluid.  In unusual cases in which the diagnosis remains unclear after physical examination, ultrasonography may be helpful.  When ultrasonography is inconclusive, transabdominal instillation of indigo carmine dye followed by observation for passage of blue fluid from the vagina will confirm ROM unequivocally. The indigo carmine test includes amniocentesis and instillation of dye into the amniotic cavity. Leakage of blue stained fluid into the vagina within 20 to 30 minutes, as evidenced by staining of a tampon, is regarded as a definitive diagnosis of PROM. Management of ROM hinges on knowledge of gestational age and evaluation of the relative risks of preterm birth versus intrauterine infection, abruptio placentae, and cord accident that could occur with expectant management (RCOG 2006; Medina and Hill, 2006; ACOG, 2007). 

Noninvasive, rapid immunoassay tests have been developed to determine ROM in pregnancy. These tests purportedly detect specific proteins found in amniotic fluid through a collection and analysis of vaginal secretions. Examples of ROM tests include, but may not be limited to the following: Actim PROM test for the detection of insulin-like growth factor binding protein (IGFBP-1); Amnisure ROM test for the detection of placental alpha microglobulin-1 (PAMG-1) protein marker; and ROM Plus utilizes a combination of monoclonal and polyclonal antibodies to detect alpha-fetoprotein (AFP) and placental protein 12 (PP12, or insulin growth factor binding protein-1).

The AmniSure ROM (Rupture of Membranes) test received Food and Drug Administration 510(k) marketing clearance in 2003 and is a rapid, non-instrumented qualitative immunochromatographic test for in-vitro detection of amniotic fluid in vaginal secretion of pregnant women.  AmniSure detects PAMG-1 (placental alpha-1 microglobulin) protein marker of the amniotic fluid in vaginal secretions and is intended to aid in the detection of ROM in pregnant women greater than 34 weeks gestation with signs, symptoms or complaints suggestive of ROM.  

A comparison study of AmniSure versus standard diagnostic methods for detection of ROM in 203 pregnant women suspected of ROM reported that the AmniSure test was highly accurate (sensitivity = 98.9 %, specificity = 100 %, and negative predictive value [NPV] = 99.1 %) in diagnosing ROM (Cousins et al, 2005).  Test performance was calculated by comparing AmniSure results against clinical history, nitrazine and fern results, presence of pooling, ultrasound (US) evidence of oligohydramnios, and findings from repeated examinations.

A study of 184 pregnant women suspected of ROM reported the sensitivity, specificity, positive predictive value (PPV) and NPV of the AmniSure device were 98.7 %, 87.5 %, 98.1 %, and 91.3 %, respectively (Lee et al, 2007).  Rupture of membranes was diagnosed if fluid was seen leaking from the cervical os or if 2 of the following 3 conditions were present:
  1. pooling of fluid,
  2. positive nitrazine test, or
  3. ferning.
Rupture of membranes was diagnosed definitively on review of the medical records after delivery.  The investigators stated that the cause of fals- positive results in 3 patients was unknown, and that the possibility of small leak that sealed over could not be excluded.

Chen and Dudenhausen (2008) compared 2 rapid strip tests for the detection of amniotic fluid, based on the detection of insulin-like growth factor-binding protein-1 (IGFBP-1) and of PAMG-1.  Samples of amniotic fluid were taken in 20 pregnant women between 31 3/7 and 41 2/7 gestational weeks at elective cesarean section before delivery of the newborn.  These samples were diluted with 0.9 % saline solution in a dilution series down to concentrations of 1:320.  Immunoassay strip tests were then compared in their ability to detect remaining concentrations of amniotic fluid.  In 5 cases, both test methods showed the same results.  In all remaining 15 cases, the test based on PAMG-1 proved to be superior by detecting amniotic fluid at least at one descending concentration below the test based on IGFBP-1.  Thus, the rapid strip test based on PAMG-1 seems to be a more sensitive bedside test compared with the test based on IGFBP-1 for the detection of amniotic fluid.

These studies indicated that the AmniSure is a promising method of detection of PPROM.  However, controlled clinical studies are needed to determine the clinical effectiveness of the AmniSure ROM test over standard diagnostic methods for ROM.

Commenting on the studies on AmniSure by Cousins et al (2005) as well as Lee et al (2007), Duff (2009) stated "[t]hese results are promising, but require further confirmation before a recommendation for routine use of this device can be made".  Caughey et al (2008) stated that "[i]n time, such noninvasive tests [as the AmniSure] may replace the need for traditional clinical assessment and amnio-dye testing for the diagnosis of PROM".

Lee and colleagues (2009) stated that the AmniSure test is approved for the diagnosis of PROM.  Yet, a fraction of patients with a positive test have intact membranes by sterile speculum examination.  The objective of this study was to determine the clinical significance of this finding.  The study population consisted of 4 groups of nulliparous women at term:
  1. not in labor without clinical evidence of ROM (n = 125);
  2. in labor without clinical ROM with a negative AmniSure test (n = 56);
  3. in labor without clinical ROM with a positive AmniSure test (n = 25); and
  4. in labor with clinical ROM (n = 30).
The AmniSure test was performed in cases without clinical ROM (groups i, ii and iii).  The AmniSure test was positive more frequently in women in labor with intact membranes than in patients not in labor at term without ROM (30.9 % (25/81 women) versus 4.8 % (6/125 women); p < 0.001).  In addition, patients in labor without clinical ROM with a positive Amnisure test had a significantly shorter admission-to-delivery interval than those in labor without clinical ROM with a negative Amnisure test (p < 0.05).  The authors concluded that a positive AmniSure test is present in about 1/3 nulliparous women at term presenting in labor with intact membranes; and patients with a positive AmniSure test had a shorter admission-to-delivery interval than those with a negative test.

A review of Amnisure by the Canadian Agency for Drugs and Technologies in Health (CADTH) identified 6 controlled clinical trials and 1 evidence-based guideline regarding the diagnostic accuracy and use of the AmniSure and other similar tests for determining whether premature rupture of fetal membranes has occurred in a pregnancy (HTIS, 2010).  No economic evaluations were identified regarding the cost-effectiveness of the AmniSure and other similar tests.  CADTH identified no relevant health technology assessments, systematic reviews, meta-analyses, or randomized controlled trials.

In a prospective cohort study, Neil and Wallace (2010) evaluated the clinical utility of Amnisure.  A total of 184 women presenting with a history of PROM to a tertiary maternity hospital were included in this study.  Before and after Amnisure, the attending clinician assessed and recorded membrane status (PROM or intact), his/her level of confidence in this diagnosis, and the intended management plan.  There was clinician uncertainty regarding the diagnosis of PROM in 83 (47 %) women.  Amnisure significantly increased clinician confidence and led to a change of intended management in 23 (13 %) women.  In 33 women presenting with possible preterm PROM, 7 thought to have PROM before Amnisure had a negative test, leading to a change of management in these women.  The authors concluded that Amnisure is clinically useful when the clinician is uncertain about the diagnosis; but not useful when the clinician is confident about the diagnosis. 

Pollet-Villard et al (2011) compared 2 biochemical tests of PROM in-vitro:
  1. Actim PROM (Medix Biochemica, Kauniainen, Finland), which detects IGFBP-1, and
  2. AmniSure (AmniSure International LLC, Cambridge, MA), which detects PAMG-1.
Samples of amniotic fluid were collected during caesarean section in 41 patients.  A dilution series was prepared and both tests were performed twice at each dilution.  Sensitivity, detection limit, response time, and reproducibility of both tests were compared.  Both tests' sensitivity was 100 % at dilution 1:10 and 1:20.  AmniSure sensitivity was higher at dilution 1:40 and 1:80 (p < 0.05).  In 29 of 40 cases, AmniSure had a lower detection limit than Actim PROM.  AmniSure response times were shorter and reproducibility was higher than Actim PROM (p < 0.05).  The authors concluded that AmniSure had a lower detection limit of amniotic fluid than Actim PROM, with a shorter response time, a higher sensitivity, and a better reproducibility.

In a case-control prospective study, Marcellin et al (2011) compared the performance of 2 rapid tests for the diagnosis of PROM based on the detection of IGFBP-1 and PAMG-1 in cervico-vaginal secretions.  Pregnant women between 24 and 41(6/7) weeks' of gestation, consulting for profuse amniotic fluid loss (group 1) or for other reasons without any rupture of membrane (group 2) were included in the study.  Successively, AmniSure test (PAMG-1) without speculum, and then Actim Prom test (IGFBP-1) during speculum examination were performed during the same visit.  A total of 80 subjects (40 in each group) were included between 25(1/7) to 41(1/7) weeks of gestation.  AmniSure diagnostic test demonstrated a sensitivity and specificity of 95 % (82.4 to 99.4) and 94.8 % (79.3 to 98), respectively and a PPV and NPV of 95 % (84.7 to 100) and 94.8 % (87.9 to 100), respectively.  Actim Prom test demonstrated a sensitivity and specificity of 97.5 % (85.7 to 100) and 97.4 % (82.4 to 99.4), respectively and a PPV and NPV of 97.5 % (88.5 to 100) and 97.4 % (92.5 to 100), respectively.  The authors concluded that both tests have similar performance to diagnose PROM.

Birkenmaier et al (2012) evaluated the performance of the PAMG-1 immunoassay (AmniSure) in cervico-vaginal secretions in patients with uncertain ROM and investigated the influence of the examiners experience.  This prospective cohort study was performed in pregnant women (17 to 42 weeks of gestation) with signs of possible ROM.  Evaluation included clinical assessment, examination for cervical leakage, nitrazine test as well as measurement of the amniotic fluid index by US and Amnisure.  Occurrence of ROM was based on review of the medical records after delivery.  A total of 199 women were included in this study.  Amnisure had a sensitivity of 94.4 %; specificity of 98.6 %; PPV of 96.2 %; NPV of 98.0 %.  Clinical assessment showed a sensitivity of 72.2 %; specificity of 97.8 %; PPV of 92.9 %; NPV of 90.6 %.  Amnisure was more sensitive for diagnosing ROM (p = 0.00596) compared to clinical assessment, independent of the examiners experience.  Furthermore, the sole use of Amnisure reduced costs by 58.4 % compared to clinical assessment.  The authors concluded that Amnisure was more sensitive compared to clinical assessment, independent of the examiners experience and gestational age. 

In a prospective observational study, Phupong and Sonthirathi (2012) compared the efficacy of PAMG-1 rapid immunoassay with conventional standard methods for the diagnosis of ROM.  Patients with symptoms or signs of PROM were included in this study.  Conventional standard methods were performed to establish the diagnosis and were compared with PAMG-1 immunoassay results.  Rupture of membrane was diagnosed if visualization of fluid leaking from the cervical os or 2 of the following 3 conditions were present: positive nitrazine test, ferning test, and nile blue test.  The diagnosis of ROM was confirmed by reviewing the medical records after delivery.  A total of 100 patients (gestational age 36.5 +/- 3.5 weeks, range of 22 to 41weeks of gestation) were recruited into the study.  Seventy-six percent were preterm and 24 % were at term.  PAMG-1 immunoassay had a sensitivity of 97.2 %, specificity of 69 %, PPV of 90.8 %, NPV of 90.9 % and an accuracy of 89 %.  In contrast, conventional combined standard methods had a sensitivity of 88.7 %, specificity of 96.6 %, PPV of 98.4 %, NPV of 77.8 %, and accuracy of 91 % for the diagnosis of ROM.  The authors concluded that PAMG-1 immunoassay is a rapid method for the diagnosis of ROM and it has a higher sensitivity than conventional standard methods for the diagnosis of ROM.

In a comparative prospective study, Abdelazim and colleagues (2012) examined the accuracy of the PAMG-1 test (AmniSure) for the diagnose PROM.  A total of 150 pregnant women after 37 weeks gestation were included in this study for induction of labor and divided into 2 groups according to the presence or absence of PROM; 75 patients with PROM were included in group I and 75 patients without PROM were included in group II as controls.  Patients with multiple pregnancies or fetal distress or vaginal bleeding or preterm labor or chorioamnionitis were excluded from this study.  Trans-abdominal US was done to detect the gestational age and the amniotic fluid index (AFI less than or equal to 5 cm in PROM) followed by sterile speculum examination to detect amniotic fluid pooling from the cervical canal and for the collection of samples.  The sensitivity and the specificity of PAMG-1 to diagnose PROM were 97.33 % and 98.67 %, respectively, compared with 84 % sensitivity and 78.67 % specificity for Ferning test and 86.67 % sensitivity and 81.33 % specificity for nitrazine test.  The PPV and NPV of PAMG-1 were 98.64 % and 97.37 %, respectively, compared with 79.74 % PPV and 83.1 % NPV for Ferning test and 82.28 % PPV and 85.91 % NPV for nitrazine test.  PAMG-1 was more accurate (98 %) for detection of PROM than Ferning (81.33 %) or nitrazine (84.0 %) tests. 

In a retrospective cohort study, Mi Lee and associates (2012) examined the frequency and clinical significance of a positive Amnisure test in patients with preterm labor and intact membranes by sterile speculum examination.  A total of 90 patients with preterm labor and intact membranes underwent Amnisure tests prior to amniocentesis (less than 72 hrs); most patients (n = 64) also underwent fetal fibronectin (fFN) tests.  Amniotic fluid (AF) was cultured for aerobic/anaerobic bacteria and genital mycoplasmas and assayed for matrix metalloproteinase-8.  The prevalence of a positive Amnisure test was 19 % (17/90).  Patients with a positive Amnisure test had significantly higher rates of adverse pregnancy and neonatal outcomes (e.g., impending preterm delivery, intra-amniotic infection/inflammation, and neonatal morbidity) than those with a negative Amnisure test.  A positive test was associated with significantly increased risk of intra-amniotic infection and/or inflammation, delivery within 7, 14, or 28 days and spontaneous preterm birth (less than 35 weeks) among patients with a negative fFN test.  The authors concluded that a positive Amnisure test in patients with preterm labor and intact membranes is a risk factor for adverse pregnancy outcome, particularly in patients with a negative fFN test.  Moreover, a positive Amnisure test in patients without symptoms or signs of ROM should not be taken as an indicator that membranes have ruptured.

An evidence review of methods to diagnose rupture of membranes by Caramore and Dresang (2011) concluded that, where diagnosis is essential and conventional testing proves equivocal, amniocentesis with injection of indigo carmine dye is the most definitive test. The authors stated that the most widely available of the newer biochemical assays, the PAMG-1 assay, appears to offer improved accuracy compared with conventional methods, but the clinical significance of a positive test, particularly in the setting of labor, is unclear.

Van der Ham et al (2012) evaluated the diagnostic accuracy of PAMG-1 and IGFBP-1 for rupture of the fetal membranes (ROM).  The authors noted that sample sizes of recent studies are small and studies used different "silver standard" definitions for ROM.  Therefore, reported results should be interpreted with caution.  The authors found that, compared to nitrazine or ferning test alone, IGFBP-1 and PAMG-1 are more accurate.  However, compared to the conventional testing (combination of history, ferning, nitrazine, speculum and ultrasound) no statistical difference in accuracy was found.  The authors concluded that IGFBP-1 and PAMG-1 seem to be sensitive and specific; however, evidence is lacking especially in equivocal cases and comparative studies against the real gold standard (amnio-dye) have still not been published.  The authors stated that further effectiveness research is needed before tests can be applied in practice.

An assessment by the Canadian Agency for Drugs and Technologies in Health (CADTH, 2012) found that AmniSure had high sensitivity and predictive accuracy for rupture of fetal membranes; however the lack of direct comparison to individual tests and limited statistical reporting prevent drawing conclusions about comparative effectiveness. Performance results suggest that AmniSure may be a useful tool for detecting membrane rupture, but no evidence related to cost-effectiveness was identified. The assessment stated that evidence-based guidelines for the use of AmniSure in clinical practice are lacking. The assessment stated that there is a limited quantity of evidence directly comparing AmniSure to conventional clinical methods, which include fern testing as one of the diagnostic criteria, for detecting rupture of fetal membranes. The assessment identified one study comparing AmniSure to the fern test alone. This study exclusively included term pregnancies and may not be generalizable to preterm membrane rupture. Other identified studies made a comparison to a suite of clinical criteria which varied between studies. These criteria included fern tests, but a positive fern test was not necessarily required to make a diagnosis, limiting the ability to draw a direct comparison. The assessment noted that all studies excluded patients with vaginal bleeding or other complications which may limit generalizability of their findings. CADTH identified no evidence-based guidelines or cost-effectiveness analyses of Amnisure.

van der Ham et al (2011) stated that PROM is a common obstetrical problem, but its diagnosis is frequently problematic.  Lacking a gold standard, the diagnosis is equivocal in some 10 % of cases.  These researchers performed a systematic review to assess the accuracy of several tests for the diagnosis of PROM in these equivocal cases.  They performed an electronic search in PubMed, Embase, DARE and the Cochrane Library and reference lists for potentially missed articles.  No language restrictions were used.  Only accuracy studies for diagnostic methods for PROM in women with equivocal PROM were selected.  The studies were scored according to STARD and QUADAS guidelines.  Based on the full description of reference and index tests, an expert panel finally decided whether the selected articles were of sufficient quality to be included.  These investigators identified 3,864 studies of which 146 full manuscripts were obtained.  They excluded 133 due to multiple reasons.  The remaining 13 studies were scored by an expert panel.  Only 3 articles with a total of 155 patients fulfilled all criteria.  These articles tested 3 different methods:
  1. pH measurement (64 patients),
  2. insulin-like growth factor binding protein-1 (ILGBP-1, 83 patients) and
  3. alpha fetoprotein (AFP, 8 patients).
&nbspSensitivity varied from 88 % (pH) to 100 % (AFP), specificity varied from 56 % (ILGPP-1) to 100 % (AFP).  Based on the limited evidence on the accuracy of tests to diagnose ruptured membranes, the authors concluded that the use of a particular test cannot be recommended.

The ROM Plus Fetal Membranes Rupture Test is a rapid, qualitative test for the in-vitro detection of amniotic fluid in vaginal secretions of pregnant women.  It detects both placenta protein 12 (PP12) and alpha-fetoprotein (AFP).  However, there is insufficient evidence regarding the effectiveness of this test.

Fichera et al (2014) evaluated the accuracy of a second-trimester rapid cervical phosphorylated IGFBP-1 (phIGFBP-1) test to predict spontaneous preterm delivery in asymptomatic twin pregnancies. During the second trimester, a rapid test to detect phIGFBP-1 in cervical secretions was performed on consecutive twin pregnancies between 2009 and 2011 to evaluate its predictive value for spontaneous preterm delivery at less than 28, less than 30, less than 32 and less than 34 weeks' gestation. Excluded were patients with cerclage, pessary or undergoing indicated preterm delivery. A total of 197 pregnancies fulfilled the study criteria and were tested at a median gestational age of 20.3 weeks (interquartile range: 20 to 20.6). Median gestational age at delivery was 36.4 weeks. Spontaneous preterm deliveries at
  1. less than 34 weeks occurred in 21 (10.7 %) cases,
  2. less than 32 weeks in 9 (4.5 %),
  3. less than 30 weeks in 6 (3 %) and
  4. less than 28 weeks in 4 (2 %).
Seventeen patients (8.7 %) were test positive: In this group, 3 patients delivered before 34 weeks' gestation, whereas none delivered at less than 32 weeks. The sensitivity, specificity, PPV and NPV of the test for spontaneous preterm delivery less than 34 weeks were 14 % (95 % confidence interval [CI]: 3 to 37 %), 92 % (86 to 95 %), 17 % (4 to 44 %) and 90 % (84 to 93 %), respectively, with a positive and negative likelihood ratio of 1.79 (0.56 to 5.74) and 0.93 (0.78 to 1.10). The authors concluded that in the second trimester, rapid cervical phIGFBP-1 testing in asymptomatic twin pregnancies has a poor performance in predicting spontaneous preterm delivery.

In an UpToDate review on “Midtrimester preterm premature rupture of membranes” (McElrath, 2015) states that “The diagnosis of midtrimester PPROM is based upon a characteristic history (leaking fluid from the vagina) and physical examination (visualization of fluid flowing from the endocervical canal), supplemented by standard laboratory tests (nitrazine, fern) in cases of diagnostic uncertainty”. It does not mention measurements of PAMG-1 (AmniSure) and IGFBP-1 (Actim PROM).

In a meta-analysis, Palacio and colleagues (2014) evaluated the published data for the accuracy of 2 amniotic fluid-specific biomarker tests for PROM:
  1. IGFBP-1 (Actim PROM) and
  2. PAMG-1 (AmniSure).
This analysis included all PubMed referenced studies related to Actim PROM and AmniSure with available data to extract performance rates. To compare accuracy, a comparison of pooled indexes of both rapid tests was performed. Studies in which both tests were used in the same clinical population were also analyzed. Membrane status, whether it was known or a suspected rupture, and inclusion or not of women with bleeding, were considered. All the available studies published in PubMed up to April 2013 were reviewed. Data were retrieved from 17 studies; 10 for Actim PROM (n = 1,066), 4 for AmniSure (n = 1,081) and 3 studies in which both biomarker tests were compared directly. The pooled analysis found that the specificity and PPV were significantly higher for AmniSure compared with Actim PROM. However, when 762 and 1,385 women with known or suspected ROM, respectively, were evaluated, AmniSure only remained significantly superior in the latter group. Furthermore, when the 2 tests were compared directly in the same study no statistically significant differences were observed. Remarkably, women with a history or evidence of bleeding were excluded in all 4 studies for AmniSure, in 2 Actim PROM studies and in 2 of the 3 studies reporting on both tests. The authors concluded that no differences were observed in the performance of the 2 tests in studies where they were used under the same clinical conditions or in women with known membrane status. They stated that although AmniSure performed better in suspected cases of PROM, this may need further analysis as exclusion of bleeding may not be representative of the real clinical presentation of women with suspected PROM.

Mariona and Roura (2016) stated that the diagnosis of the status of the fetal membranes has traditionally been reduced to either intact or ruptured. In the last decades, evidence has accumulated demonstrating that this clinical approach may well be an over-simplification. Practically, all maternal organs experienced physiologic or eventually pathologic changes during the length of the gestational period. These investigators proposed that the fetal membranes are also significantly impacted by those changes. The accurate, specific, simplified and low-cost diagnosis of the status of the fetal membranes is of critical importance for the assessment of risk to the pregnancy followed by efficient and prompt treatment. The presence of PAMG-1 in the vagina specifically indicates a disruption in the integrity of the fetal membranes and may indirectly mean increased risk for preterm birth. The authors concluded that further research to properly characterize this marker and its importance in the care of pregnant woman at risk for preterm birth is strongly recommended.

Rogers and colleagues (2016) compared the diagnostic performance characteristics between 2 methods used for the detection of ROM as measured in the same patient. Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus) in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid.  Both tests were compared to analytical confirmation of ROM using 3 external laboratory tests.  Diagnostic performance characteristics were calculated including sensitivity, specificity, PPV, NPV, and accuracy.  Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100 % versus 77.8 %), specificity (94.8 % versus 79.3 %), PPV (75 % versus 36.8 %), NPV (100 % versus 95.8 %), and accuracy (95.5 % versus 79.1 %).  The authors concluded that the point-of-care immunoassay test provided improved diagnostic accuracy for the detection of ROM compared to fern testing.  They stated that it has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.

Chorioquick

In a prospective, cohort study, Eleje and colleagues (2020) determined the accuracy of a semi-quantitative interleukin-6 (IL-6) vaginal secretion rapid test (Chorioquick) for detecting chorioamnionitis in women with PROM.  This trial entailed women with confirmed PROM at term and pre-term PROM with or without suspected chorioamnionitis from August 1, 2017, to October 31, 2018.  Cervico-vaginal fluid samples were tested for chorioamnionitis using the Chorioquick test.  Samples were repeated at decision to deliver.  The test was considered positive if at least the indicator "IL-6 low" of the 3 Chorioquick biomarkers (low, medium, high) was positive, or negative if none of the biomarkers was positive.  Chorioamnionitis was histologically confirmed post-delivery using 3 tissue samples.  Primary outcome measures were sensitivity, specificity, and accuracy.  Of 73 women, on histological confirmation, 39 were true positive and 29 were true negative (for chorioamnionitis) to the Chorioquick test at repeat assessment.  Overall, the Chorioquick test had a sensitivity of 97.5 % (95 % CI: 85.3 to 99.9), specificity 87.9 % (70.9 to 96.0), and accuracy 93.2 % (79.5 to 99.1).  Sub-group analysis of women of less than 37 weeks of pregnancy showed a sensitivity of 100.0 % (95 % CI: 83.4 to 100.0), specificity of 91.3 % (70.5 to 98.5), and accuracy of 95.8 % (82.5 to 99.5).  Triple positive samples were 100.0 % specific in all gestations.  The authors concluded that Chorioquick showed favorable utility for detecting chorioamnionitis in PROM and could be a reliable, non-invasive rapid tool in a real-world clinical setting.  These findings need to be validated by well-designed studies.

The FDA has been warned about misuse, over-reliance, and inaccurate interpretation of lab test results from ROM tests used to detect rupture of membranes in pregnant women (FDA, 2020). The FDA stated that these can lead to serious adverse events, including fetal death, infection, and other health complications in pregnant women. The FDA stated that they are aware of adverse events related to the use of ROM tests, including 13 fetal deaths and multiple reports of health complications in pregnant women. In addition, the FDA stated that they have received information which indicates that health care providers may be over-relying on ROM test results when making critical patient management decisions, despite labeling instructions warning against this practice.

Guidelines on Prelabor Rupture of Membranes from the American College of Obstetricians and Gynecologists (2020) noted high false positive rates with commercially available tests, and problems with their clinical validation. "At most these test kits should be considered selectively relative to standard methods of diagnosis."

Evaluation of Vaginal Microbiome Profiles

In a prospective, cohort study, Paramel and associates (2016) characterized the vaginal microbiota of women following (PPROM, and examined if microbiome composition predicted latency duration and perinatal outcomes.  Participant were women with PPROM between 24+0 and 33+6 weeks gestational age (GA).  Microbiome profiles, based on pyro-sequencing of the cpn60 universal target, were generated from vaginal samples at time of presentation with PPROM, weekly thereafter, and at delivery.  Main outcome measures were vaginal microbiome composition, latency duration, GA at delivery, perinatal outcomes.  Microbiome profiles were generated from 70 samples from 36 women.  Mean GA at PPROM was 28.8 weeks (mean latency of 2.7 weeks).  Microbiome profiles were highly diverse but sequences representing Megasphaera type 1 and Prevotella spp. were detected in all vaginal samples.  Only 13/70 samples were dominated by Lactobacillus spp. Microbiome profiles at the time of membrane rupture did not cluster by GA at PPROM, latency duration, presence of chorio-amnionitis or by infant outcomes.  Mycoplasma and/or Ureaplasma were detected by PCR in 81 % (29/36) of women, and these women had significantly lower GA at delivery and correspondingly lower birth-weight infants than Mycoplasma and/or Ureaplasma negative women.  The authors concluded that women with PPROM had mixed, abnormal vaginal microbiota; but the microbiome profile at PPROM did not correlate with latency duration.  Prevotella spp. and Megasphaera type I were ubiquitous.  The presence of Mollicutes in the vaginal microbiome was associated with lower GA at delivery.  The microbiome was remarkably unstable during the latency period.  Moreover, they stated that the highly unstable vaginal microbiota of women in this study demonstrated the need for more intense study of the relationship of genital tract microbiota with PPROM, including functional analysis of these microbial communities.  These researchers noted that future work should involve larger studies including sampling before/after membrane rupture, to ascertain the predisposing microbiome leading to membrane rupture.

The authors stated that the main drawbacks of this study were the relatively small number of women followed (n = 36) and the lack of pre-rupture samples as prediction of PPROM is very difficult.  The standard use of broad-spectrum antibiotics in the context of PPROM meant that the natural changes of the microbiome during latency could no longer be evaluated.  These researchers stated that ongoing studies by their group were assessing the microbiomes of women in pregnancy, to establish the pre-rupture microbiome and to try to ascertain causality rather than association of microbial profiles with adverse perinatal outcomes.

Fetal Membrane Imaging

Nunes and colleagues (2016) PPROM is the largest identifiable cause of preterm birth.  There is currently no good screening test for PPROM in low-risk asymptomatic patients.  These investigators examined how imaging methods can be utilized for assessing the risks for PPROM in asymptomatic patients.  They carried out a systematic review of the literature on fetal membrane thickness and its use for the prediction of PPROM; 4 key studies were identified and reviewed; 2 in-vitro studies and 2 in-vivo US studies each using differing methodologies.  Additionally reviewed was a study using optical coherence tomography, an emerging technique using near-infrared technology to produce high-resolution images.  There is currently insufficient data to determine the association between fetal membrane thickness and PPROM by ultrasound.  The authors concluded that fetal membrane thickness could have relevant clinical ramifications for the prediction of PPROM.  Suggested improvements in study methodology and design would lead to progress in this area of research, as well as the use of newer technologies.  They stated that larger sample sizes, histological comparison, uniform methodologies for data collection, longitudinal study design and expanding data analysis beyond fetal membrane thickness to other properties would expand the knowledge in this field.  Furthermore, they stated that emerging technologies such as shear wave elastography, optical coherence tomography and fusion MRI imaging hold the promise of improved examination of the fetal membranes.  Along with advances in ultrasound technology, future studies may be able to identify characteristics of the fetal membranes that are predictive of PPROM; such a finding would aid in better understanding this important cause of preterm birth and possibly help clinicians mitigate its associated morbidity and mortality.

The Biobeat Monitoring Platform for Monitoring Rupture of Membranes

Atzmon and colleagues (2020) examined continuous monitoring of maternal hemodynamics during labor and delivery by means of an innovative, non-invasive, reflective photoplethysmography (PPG)-based device.  The Biobeat Monitoring Platform includes a wearable wrist-watch monitor that automatically samples cardiac output (CO), blood pressure (BP), stroke volume (SV), systemic vascular resistance (SVR), heart rate (HR) every 5 s and uploads all data to a smartphone-based app and to a data cloud, enabling remote patient monitoring and analysis of data.  Low-risk parturients at term, carrying singletons pregnancies, were recruited at early delivery prior to the active phase.  Data analysis of the collected data was carried out using the Power BI analysis tool (Microsoft).  Data were normalized to visual presentation using Excel Data Analysis and the regression tool.  Average measurements were compared before and after ROM, epidural anesthesia (EA), fetal delivery, and placental expulsion.  A total of 81 parturients were included in the analysis.  Epidural anesthesia was associated with a slight elevation in CO (5.5 versus 5.6, L/min, 10 min before and after EA, p < 0.05) attributed to a non-significant increase in both HR and SV.  BP remained stable as of counter decrease in SVR (1,361 versus 1,319 mmHg/min/ml, 10 mins before and after EA, p < 0.05).  Fetal delivery was associated with a peak in CO after which it rapidly declined (6.0 versus 7.2 versus 6.1 L/min, 30 mins before versus point of delivery versus after delivery, p < 0.05).  The mean BP remained stable throughout delivery with a slight increase at fetal delivery (92 versus 95 versus 92.1 mmHg, p < 0.05), reflecting the increase in CO and decrease in SVR (1,284 versus 1,112 versus 1,280 mmHg/min/ml, p < 0.05) with delivery.  Placental expulsion was associated with a 2nd peak in CO and decrease in SVR.  The authors presented a novel application of non-invasive hemodynamic maternal monitoring throughout labor and delivery for both research and clinical use.  This review also showed that no maternal hemodynamics changes were documented following ROM.  Moreover, these researchers stated that further studies should focus on hemodynamic monitoring in parturients with pre-existing cardiovascular or obstetrical complications such as pre-eclampsia and use these data to define normal and abnormal values for creation of safety protocols during labor and delivery.

The authors stated that this study was limited due to the small sample size (n = 81).  Furthermore, since this study was observational, these investigators could not control measurements for variables such as maternal positioning, fluid management, maternal anxiety, timing of bearing down, etc.  Lastly, these researchers did not examine the change in hemodynamic parameters in different settings of maternal and obstetrical complications such as previous cardiovascular disease and acute bleeding.

Functional Placental Magnetic Resonance Imaging for Evaluation of Infection/Inflammation in Women with PPROM

Hutter et al (2021) stated that PPROM complicates 3 % of pregnancies in the United Kingdom.  Where delivery does not occur spontaneously, expectant management until 37 weeks of gestation is advocated, unless signs of maternal infection develop.  However, clinical presentation of maternal infection can be a late sign and injurious fetal inflammatory responses may already have been activated.  Thus, there is a need for more sensitive markers to aid optimal timing of interventions.  Currently, there is no non-invasive test in clinical practice to examine for infection in the fetal compartment and definitive diagnosis of chorioamnionitis is by histological assessment of the placenta following delivery.  These researchers presented comprehensive functional placental magnetic resonance imaging (MRI) quantification, already used in other organ systems, to examine for infection/inflammation, in women with and without PPROM aiming to explore its use as a biomarker for inflammation within the feto-placental compartment in-vivo.  Placental MRI scans were performed in a cohort of 12 women (with 1 having 2 scans) with PPROM before 34 weeks of gestation (selected because of their high risk of infection), and in a control group of 87 women.  Functional placental assessment was carried out with magnetic resonance techniques sensitive to changes in the microstructure (diffusion) and tissue composition (relaxometry), with quantification performed both over the entire organ and in regions of interest between the basal and chorionic plate.  Placental histology was analyzed after delivery where available.  Normative evolution of functional magnetic resonance biomarkers over gestation was studied.  Cases of inflammation, as evaluated by histological presence of chorioamnionitis, and umbilical cord vasculitis with or without funisitis, were associated with lower T2* (mean T2* at 30 weeks 50 ms compared with 58 ms in controls) and higher fractional anisotropy (mean at 30 weeks 0.55 compared with 0.45 in controls).  These differences did not reach significance and there was substantial heterogeneity both in T2* and Apparent Diffusivitiy across the cohort.  The authors concluded that this 1st exploration of functional placental assessment in a cohort of women with PPROM demonstrated that functional placental MRI could reveal a range of placental changes associated with inflammatory processes.  These investigators stated that functional placental MRI is a promising tool to gain information; and in the future to identify inflammation in-vivo, it could therefore assist in improving optimal timing for interventions designed to prevent fetal injury.


References

The above policy is based on the following references:

  1. Abdelazim IA, Makhlouf HH. Placental alpha microglobulin-1 (AmniSure(®) test) for detection of premature rupture of fetal membranes. Arch Gynecol Obstet. 2012;285(4):985-989.
  2. American College of Obstetricians and Gynecologists (ACOG), Committee on Practice Bulletins. Premature rupture of membranes. Clinical Management Guidelines for Obstetrician-Gynecologists No. 80. Washington, DC: ACOG; April 2007.
  3. American College of Obstetricians and Gynecologists (ACOG). Practice Bulletin No. 160: Premature Rupture of Membranes. Obstet Gynecol. 2016;127(1):e39-e51. 
  4. American College of Obstetricians and Gynecologists (ACOG). Practice Bulletin No. 188: Prelabor Rupture of Membranes. Obstet Gynecol. 2018;131(1):e1-e14.
  5. American College of Obstetricians and Gynecologists (ACOG). Practice Bulletin No. 217. Prelabor Rupture of Membranes. Obstet Gynecol. 2020;135(3):e80-e97. 
  6. Atzmon Y, Ishay EB, Hallak M, et al. Continuous maternal hemodynamics monitoring at delivery using a novel, noninvasive, wireless, PPG-based sensor. J Clin Med. 2020;10(1):8.
  7. Birkenmaier A, Ries JJ, Kuhle J, et al. Placental α-microglobulin-1 to detect uncertain rupture of membranes in a European cohort of pregnancies. Arch Gynecol Obstet. 2012;285(1):21-25.
  8. Canadian Agency for Drugs and Technologies in Health (CADTH). AmniSure versus fern testing to assess the rupture of fetal membranes in pregnant women: A review of the comparative accuracy, cost-effectiveness, and guidelines. Rapid Response Report: Summary with Critical Appraisal. Ottawa, ON: CADTH; April 4, 2012. 
  9. Caramore T, Dresang LT. What is the best way to diagnose rupture of membranes? Evid Based Pract. 2011;14(6):5.
  10. Caughey AB, Robinson JN, and Norwitz, ER. Contemporary diagnosis and management of preterm premature rupture of membranes. Rev Obstet Gynecol. 2008;1(1):11-22.
  11. Chen FC, Dudenhausen JW. Comparison of two rapid strip tests based on IGFBP-1 and PAMG-1 for the detection of amniotic fluid. Am J Perinatol. 2008;25(4):243-246.
  12. Cousins LM, Smok DP, Lovett SM, et al. AmniSure placental alpha microglobulin-1 rapid immunoassay versus standard diagnostic methods for detection of rupture of membranes. Am J Perinatol. 2005;22(6):317-320.
  13. Deckmyn B, Chieux V, Ammeux F, et al. Comparison of immunochromatographic tests Actim(®) Prom and Amnioquick(®) Duo for the rapid detection of premature rupture of membranes. Ann Biol Clin (Paris). 2015;73(4):407-411.
  14. Duff P. Preterm premature rupture of membranes. UpToDate [online serial]. Waltham, MA: UpToDate; 2009.
  15. Eleje GE, Ukah CO, Onyiaorah IV, et al. Diagnostic value of Chorioquick for detecting chorioamnionitis in women with premature rupture of membranes. Int J Gynaecol Obstet. 2020;149(1):98-105.
  16. Fichera A, Prefumo F, Zanardini C, et al. Rapid cervical phIGFBP-1 test in asymptomatic twin pregnancies: Role in mid-pregnancy prediction of spontaneous preterm delivery. Prenat Diagn. 2014;34(5):450-459.
  17. Health Technology Inquiry Service (HTIS). Use of AmniSure to assess possible premature rupture of fetal membranes in a pregnancy: Diagnostic accuracy, cost-effectiveness, and guidelines. Health Technology Assessment HTA. Ottawa, ON: Canadian Agency for Drugs and Technologies in Health (CADTH); March 15, 2010.
  18. Hutter J, Jackson L, Ho A, et al. The use of functional placental magnetic resonance imaging for assessment of the placenta after prolonged preterm rupture of the membranes in vivo: A pilot study. Acta Obstet Gynecol Scand. 2021;100(12):2244-2252.
  19. Lee SE, Park JS, Norwitz ER, et al. Measurement of placental alpha-microglobulin-1 in cervicovaginal discharge to diagnose rupture of membranes. Obstet Gynecol. 2007;109(3):634-640.
  20. Lee SM, Lee J, Seong HS, et al. The clinical significance of a positive Amnisure test in women with term labor with intact membranes. J Matern Fetal Neonatal Med. 2009;22(4):305-310.
  21. Marcellin L, Anselem O, Guibourdenche J, et al. Comparison of two bedside tests performed on cervicovaginal fluid to diagnose premature rupture of membranes. J Gynecol Obstet Biol Reprod (Paris). 2011;40(7):651-656.
  22. Mariona FG, Roura LC. The role of placental alpha microglobulin-1 amnisure in determining the status of the fetal membranes; Its association with preterm birth. Traditions … traditions …. J Matern Fetal Neonatal Med. 2016;29(6):1016-1020.
  23. McElrath T. Midtrimester preterm premature rupture of membranes. UpToDate [online serial]. Waltham, MA: UpToDate; reviewed July 2015.
  24. Medina TM, Hill DA. Preterm premature rupture of membranes: Diagnosis and management. Am Fam Physician. 2006;73(4):659-664.
  25. Mi Lee S, Romero R, Park JW, et al. The clinical significance of a positive Amnisure test in women with preterm labor and intact membranes. J Matern Fetal Neonatal Med. 2012;25(9):1690-1698.
  26. Neil PR, Wallace EM. Is Amnisure® useful in the management of women with prelabour rupture of the membranes? Aust N Z J Obstet Gynaecol. 2010;50(6):534-538. 
  27. Nunes V, Cross J, Speich JE, et al. Fetal membrane imaging and the prediction of preterm birth: A systematic review, current issues, and future directions. BMC Pregnancy Childbirth. 2016;16(1):387.
  28. Palacio M, Kühnert M, Berger R, et al. Meta-analysis of studies on biochemical marker tests for the diagnosis of premature rupture of membranes: Comparison of performance indexes. BMC Pregnancy Childbirth. 2014;14:183.
  29. Paramel Jayaprakash T, Wagner EC, van Schalkwyk J, et al. High diversity and variability in the vaginal microbiome in women following preterm premature rupture of membranes (PPROM): A prospective cohort study. PLoS One. 2016;11(11):e0166794.
  30. Phupong V, Sonthirathi V. Placental alpha-microglobulin-1 rapid immunoassay for detection of premature rupture of membranes. J Obstet Gynaecol Res. 2012;38(1):226-230.
  31. Pollet-Villard M, Cartier R, Gaucherand P, Doret M. Detection of placental alpha microglobulin-1 versus insulin-like growth factor-binding protein-1 in amniotic fluid at term: A comparative study. Am J Perinatol. 2011;28(6):489-494.
  32. Rogers LC, Scott L, Block JE. Accurate point-of-care detection of ruptured fetal membranes: Improved diagnostic performance characteristics with a monoclonal/polyclonal immunoassay. Clin Med Insights Reprod Health. 2016;10:15-18.
  33. Royal College of Obstetricians and Gynaecologists (RCOG), Scientific Advisory Committee. Preterm prelabour rupture of membranes. Clinical Green Top Guidelines No. 44. London, UK: RCOG; November 2006.
  34. Schmitz T, Sentilhes L, Lorthe E, et al. Preterm premature rupture of the membranes: Guidelines for clinical practice from the French College of Gynaecologists and Obstetricians (CNGOF). Eur J Obstet Gynecol Reprod Biol. 2019;236:1-6.
  35. Simhan HN, Canavan TP. Preterm premature rupture of membranes: Diagnosis, evaluation and management strategies. BJOG. 2005;112 Suppl 1:32-37.
  36. Tsakiridis I, Mamopoulos A, Chalkia-Prapa EM, et al. Preterm premature rupture of membranes: A review of 3 national guidelines. Obstet Gynecol Surv. 2018;73(6):368-375.
  37. U.S. Food and Drug Administration (FDA). 510(k) summary: Actim ROM. Silver Spring, MD: FDA; January 25, 2007.
  38. U.S. Food and Drug Administration (FDA). 510(k) summary: AmniSure ROM (rupture of fetal membrane) test. Silver Spring, MD: FDA; January 9, 2009.
  39. U.S. Food and Drug Administration (FDA). 510(k) summary: ROM Plus Fetal Membranes Rupture Test. Silver Spring, MD: FDA; November 23. 2011.
  40. U.S. Food and Drug Administration (FDA). Risks Associated with Use of Rupture of Membranes Tests - Letter to Health Care Providers. Silver Spring, MD: FDA; August 9, 2018.
  41. van der Ham DP, van Melick MJ, Smits L, et al. Methods for the diagnosis of rupture of the fetal membranes in equivocal cases: A systematic review. Eur J Obstet Gynecol Reprod Biol. 2011;157(2):123-127.
  42. van der Ham DP, van Teeffelen AS, Mol BW. Prelabour rupture of membranes: Overview of diagnostic methods. Curr Opin Obstet Gynecol. 2012;24(6):408-412.