Influenza Rapid Diagnostic Tests

Number: 0476

Table Of Contents

Policy
Applicable CPT / HCPCS / ICD-10 Codes
Background
References


Policy

Scope of Policy

This Clinical Policy Bulletin addresses influenza rapid diagnostic tests.

  1. Medical Necessity

    Aetna considers rapid diagnostic tests for viral influenza (e.g., Directigen Flu A, Directigen Flu A+B, Flu OIA, Quickvue Influenza Test, and Z Stat Flu) medically necessary.

  2. Related Policies


Table:

CPT Codes / HCPCS Codes / ICD-10 Codes

Code Code Description

Information in the [brackets] below has been added for clarification purposes.   Codes requiring a 7th character are represented by "+":

CPT codes covered if selection criteria are met:

87804 Infectious agent antigen detection by immunoassay with direct optical observation; influenza

ICD-10 codes covered if selection criteria are met:

B34.9 Viral infection, unspecified
J10.00 - J11.89 Influenza due to other influenza virus
M79.10 - M79.18 Myalgia
R05 Cough
R50.9 Fever, unspecified
R06.02 Shortness of breath
R51 Headache
R53.81 Other malaise

Background

In the context of an epidemic, the clinical diagnosis of influenza in a patient with fever, malaise, and respiratory symptoms can be made with some certainty.  In the absence of an epidemic of influenza, however, the diagnosis may be uncertain.  In these cases, rapid diagnostic tests (which take less than 1 hour to perform) may be helpful in distinguishing influenza from infection with a number of other viruses (and occasionally streptococcal pharyngitis) that produce headache, muscle aches, fever, and/or cough.  The results of these rapid diagnostic tests for influenza may be useful in selecting appropriate antiviral therapy, avoiding inappropriate antibiotic therapy, and in promptly initiating measures to decrease the spread of disease.

Most of the rapid diagnostic tests that can be done in a physician's office are approximately greater than 70 % sensitive for detecting influenza and approximately greater than 90 % specific (CDC, 2005).  Thus, as many as 30 % of samples that would be positive for influenza by viral culture may give a negative rapid test result.  In addition, some rapid test results may indicate influenza when a person is not infected with influenza.

Guidelines from the Centers for Disease Control and Prevention (CDC) (Harper et al, 2005) explain that commercial rapid diagnostic tests can detect influenza viruses within 30 mins.  Some tests are approved for use in any outpatient setting, whereas others must be used in a moderately complex clinical laboratory.  These rapid tests differ in the types of influenza viruses they can detect and whether they can distinguish between influenza types.  Different tests can detect:
  1. only influenza A viruses;
  2. both influenza A and B viruses, but not distinguish between the 2 types; or
  3. both influenza A and B and distinguish between the two.

Centers for Disease Control and Prevention guidelines explain that none of the tests provide any information about influenza A subtypes.  The types of specimens acceptable for use (i.e., throat, nasopharyngeal, or nasal aspirates, swabs, or washes) also vary by test.  The specificity and, in particular, the sensitivity of rapid tests are lower than for viral culture and vary by test.  The CDC recommends that, because of the lower sensitivity of the rapid tests, physicians should consider confirming negative tests with viral culture or other means because of the possibility of false-negative rapid test results, especially during periods of peak community influenza activity.  In contrast, false-positive rapid test results are less likely, but can occur during periods of low influenza activity.  Therefore, when interpreting results of a rapid influenza test, physicians should consider the positive- and negative-predictive values of the test in the context of the level of influenza activity in their community (Harper et al, 2005).  Package inserts and the laboratory performing the test should be consulted for more details regarding use of rapid diagnostic tests.

Centers for Disease Control and Prevention guidelines state that, despite the availability of rapid diagnostic tests, collecting clinical specimens for viral culture is critical, because only culture isolates can provide specific information regarding circulating strains and subtypes of influenza viruses.  The guidelines explain that this information is needed to compare current circulating influenza strains with vaccine strains, to guide decisions regarding influenza treatment and chemoprophylaxis, and to formulate vaccine for the coming year.  Virus isolates also are needed to monitor the emergence of antiviral resistance and the emergence of novel influenza A subtypes that might pose a pandemic threat.

Although widely used in emergency departments and physicians' offices, antigen-based rapid assays have shown poor sensitivity for the H1N1 virus compared with culture or molecular diagnostic techniques.  Drexler et al (2009) found only 11 % sensitivity of a rapid antigen test with reverse transcription polymerase chain reaction (RT-PCR).  Investigators compared the sensitivity of a commercially available antigen-based rapid test (BinaxNOW Influenza A & B Rapid Test) with that of a real-time RT-PCR (rRT-PCR) assay specific for the hemagglutinin gene of the 2009 H1N1 virus.  Of 1,838 clinical specimens tested, 221 were confirmed as H1N1 positive by RT-PCR.  When 144 of these PCR-positive specimens were evaluated using the rapid-antigen test, results were positive for only 16 (11.1 %).  The "gold standard" PCR also demonstrated poor sensitivity, detecting the 2009 H1N1 virus in just 12 % of 1,838 respiratory specimens submitted at a time when this virus was pandemic and probably responsible for most influenza-like illness.

During May 2009, a few weeks after 2009 pandemic influenza A (H1N1) infection was first detected in the United States, outbreaks among students from 2 schools were detected in Greenwich, Connecticut (CT).  Staff members from Greenwich Hospital and the CT Department of Public Health collected data on symptoms for 63 patients and submitted naso-pharyngeal washings for testing using a rapid influenza diagnostic test (RIDT) for influenza A and B and rRT-PCR assay, thus affording an opportunity to assess the field performance of the RIDT.  A total of 49 patients had infections with pandemic H1N1 confirmed by rRT-PCR (CDC, 2009).  The findings of this performance assessment indicated that, compared with rRT-PCR, the sensitivity of the RIDT for detecting infection in patients with 2009 pandemic H1N1 was 47 %, and the specificity was 86 %.  Sensitivity and specificity did not vary markedly by the presence or absence of CDC-defined influenza-like illness (ILI) or by time from symptom onset to specimen acquisition.  In this group of patients, although positive RIDT results performed well in predicting confirmed infection with pandemic H1N1 virus (positive predictive value: 92 %), negative tests did not accurately predict the absence of infection (negative predictive value: 32 %).  These findings affirm recent CDC recommendations against using negative RIDT results for management of patients with possible 2009 pandemic H1N1 infection.

Hawkes et al (2010) examined the diagnostic accuracy of a RIDT and direct fluorescent antibody (DFA) assay for swine-origin H1N1 virus (S-OIV) by using rRT-PCR as the reference standard.  These investigators prospectively recruited children (aged 0 to 17 years) assessed in the emergency department of a pediatric referral hospital and a community pediatric clinic for ILI between May 22 and July 25, 2009.  RIDT (performed on-site) and DFA were compared with rRT-PCR to determine their sensitivity and specificity for S-OIV.  They also compared the sensitivity of RIDT for S-OIV to that for seasonal influenza over 2 preceding seasons.  Of 820 children enrolled, 651 were from the emergency department and 169 were from the clinic.  Sensitivity of RIDT was 62 % (95 % confidence interval [CI]: 52 % to 70 %) for S-OIV, with a specificity of 99 % (95 % CI: 92 % to 100 %).  Sensitivity of DFA was 8 3% (95 % CI: 75 % to 89 %) and was superior to that of RIDT (p < 0.001).  Sensitivity of RIDT for S-OIV was comparable to that for seasonal influenza when using DFA supplemented with culture as the reference standard.  Sensitivity of RIDT for influenza viruses was markedly higher in children 5 years of age or younger (p = 0.003) and in patients presenting less than or equal to 2 days after symptom onset (p < 0.001).  The authors concluded that the sensitivity of RIDT for detection of S-OIV is higher than recently reported in mixed adult-pediatric populations but remains suboptimal.

Cruz and associates (2010) evaluated the performance of a RIDT in detecting H1N1 2009 influenza A virus in respiratory samples from pediatric patients in comparison to that of rRT-PCR and viral culture.  Patients for whom the RIDT, viral culture, and rRT-PCR results were known were included.  Sensitivity, specificity, and likelihood ratios (LRs) were calculated.  A total of 3,030 specimens had RIDT results paired with both rRT-PCR and viral culture results.  With rRT-PCR as the reference, overall test sensitivity was 45 % (95 % CI: 43.3 % to 46.3 %) and specificity was 98.6 % (95 % CI: 98.1 % to 99 %).  Positive and negative LRs were 32.9 (95 % CI: 22.9 to 45.4) and 0.56 (95 % CI: 0.54 to 0.58), respectively.  Sensitivity of RIDT was significantly higher in young infants and children younger than 2 years than in older children.  Using viral culture as the reference standard, RIDT sensitivity was 55.5 % (95 % CI: 51.9 % to 95.6 %) and specificity was 95.6 % (95 % CI: 95 % to 96.1 %).  The positive and negative LRs were 12.6 and 0.47, respectively.  The authors concluded that the RIDT had relatively poor sensitivity but excellent specificity in this consecutive series of respiratory specimens obtained from pediatric patients.  Although a positive RIDT result was highly accurate in predicting infection with influenza type A H1N1 2009 in children, a negative RIDT result did not preclude a child having H1N1.  Thus, for children at high-risk with ILI during high prevalence periods of influenza, empiric initiation of antiviral therapy should be considered for patients with a negative RIDT result.

Parida et al (2011) stated that the recent emergence of the S-OIV poses a serious global health threat.  Rapid detection and differentiation of S-OIV from seasonal influenza is crucial for patient management and control of the epidemics.  These researchers reported a 1-step, single-tube accelerated and quantitative S-OIV-specific H1 reverse transcription loop-mediated isothermal amplification (RTLAMP) assay for clinical diagnosis of S-OIV by targeting the H1 gene.  A comparative evaluation of the H1-specific RTLAMP assay vis-a-vis the World Health Organization (WHO)-approved rRT-PCR, involving 239 acute-phase throat swab samples, demonstrated exceptionally higher sensitivity by picking up all of the 116 H1N1-positive cases and 36 additional positive cases among the negatives that were sequence-confirmed as S-OIV H1N1.  None of the rRT-PCR-positive samples were missed by the RTLAMP system.  The comparative analysis revealed that S-OIV RTLAMP was up to 10-fold more sensitive than the WHO rRT-PCR; it had a detection limit of 0.1 tissue culture infectious dosage of (50)/ml.  One of the most attractive features of this isothermal gene amplification assay is that it seems to have an advantage in monitoring gene amplification by means of SYBR Green I dye-mediated naked-eye visualization within 30 mins compared to 2 to 3 hours for a eRt-PCR.  This suggested that the RTLAMP assay is a valuable tool for rapid, real-time detection and quantification of S-OIV in acute-phase throat swab samples without requiring sophisticated equipment.

Su and colleagues (2012) applied the developed paired surface plasma waves biosensor (PSPWB) in a dual-channel biosensor for rapid and sensitive detection of S-OIV.  In conjunction with the amplitude ratio of the signal and the reference channel, the stability of the PSPWB system is significantly improved experimentally.  The theoretical limit of detection (LOD) of the dual-channel PSPWB for S-OIV is 30 PFU/mL (PFU, plaque-forming unit), which was calculated from the fitting curve of the surface plasmon resonance signal with a S-OIV clinical isolate concentration in phosphate-buffered saline (PBS) over a range of 18 to 1.8 × 10(6) PFU/ml.  The LOD is 2 orders of magnitude more sensitive than the commercial rapid influenza diagnostic test at worst and an order of magnitude less sensitive than rRT-PCR whose LOD for S-OIV in PBS was determined to be 3.5 PFU/ml in this experiment.  Furthermore, under in-vivo conditions, this experiment demonstrates that the assay successfully measured S-OIV at a concentration of 1.8 × 10(2) PFU/ml in mimic solution, which contained PBS-diluted normal human nasal mucosa.  Most importantly, the assay time took less than 20 mins.  The authors concluded that from thees findings, the dual-channel PSPWB potentially offers great opportunity in developing an alternative PCR-free diagnostic method for rapid, sensitive, and accurate detection of viral pathogens with epidemiological relevance in clinical samples by using an appropriate pathogen-specific antibody.

Multiplex Real-Time Reverse-Transcription Polymerase Chain Reaction Assays for Diagnosis of Seasonal Influenza Viruses

Mancini and colleagues (2021) noted that pandemic coronavirus disease 2019 (COVID-19) disease represents a challenge for healthcare structures.  The molecular confirmation of samples from infected individuals is crucial and therefore guides public health decision-making.  Clusters and possibly increased diffuse transmission could occur in the context of the next influenza season.  For this reason, a diagnostic test able to discriminate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from influenza viruses is urgently needed.  These researchers examined a multiplex real-time reverse-transcription polymerase chain reaction (PCR) assay using 1 laboratory protocol with different real-time PCR instruments.  Overall, 1,000 clinical samples (600 from samples SARS-CoV-2-infected patients, 200 samples from influenza-infected patients, and 200 negative samples) were analyzed. The assay developed was able to detect and discriminate each virus target and to intercept co-infections.  The limit of quantification of each assay ranged between 5 and 10 genomic copy numbers, with a cut-off value of 37.7 and 37.8 for influenza and SARS-CoV-2 viruses, respectively.  Only 2 influenza co-infections were detected in COVID-19 samples.  The authors concluded that the findings of this study suggested that multiplex assay is a rapid, valid, and accurate method for the detection of SARS-CoV-2 and influenza viruses in clinical samples.  The test may be an important diagnostic tool for both diagnostic and surveillance purposes during the seasonal influenza activity period.  Moreover, these researchers stated that it will be necessary to examine if the method might be affected by the co-presence of other respiratory pathogens in the clinical samples. 

The authors stated that the major drawback of this study was the relatively small sample size.  Although these investigators tested approximately 1,000 clinical specimens, the number of samples positive for influenza specimens was very low.  In this regard, it should be considered that the influenza active surveillance activities globally decreased because of the COVID-19 pandemic and a low number of samples was collected during the influenza season (2019 to 2020) in Italy.  Moreover, it should be noted that also during the SARS pandemic in 2003, only 5 % of mixed infection with influenza viruses was reported, though it tended to increase over time.

Additional information concerning diagnostic testing for influenza is available at Clinical Description and Lab Diagnosis of Influenza.

The Quidel Sofia Rapid Influenza Fluorescent Immunoassay

In a prospective study, Yang and co-workers (2018) examined the diagnostic performance of the Sofia influenza A+B fluorescent immunoassay (Sofia FIA).  This trial was carried out at the Chang Gung Memorial Hospital in Taiwan from January 2012 to December 2013.  Patients who presented at outpatient clinics or the emergency department with influenza-like illness (ILI) were included.  Upper respiratory tract specimens were collected from oropharynx or nasopharynx.  Performance of the Sofia FIA was compared to that of the Formosa One Sure Flu A/B Rapid Test.  A real-time reverse transcriptase-polymerase chain reaction assay (RT-PCR) and/or virus culture were used as reference standards.  Of the 109 enrolled patients, the sensitivity, specificity, positive, and negative predictive values (PPV and NPV) of the Sofia FIA to detect influenza A virus were 82 %, 89 %, 77 %, and 89 %, respectively.  These parameters were 100 % when the samples were from nasopharynx.  The PPV for influenza B virus detection was 29 %.  The sensitivity of the Sofia FIA for detection of influenza A virus was 93 % between days 2 and 4 after onset of symptoms.  For specimens with low viral loads (RT-PCR cycle threshold between 30 and 34.9), the sensitivity of the Sofia FIA was 83 % (10/12).  The Sofia FIA performed effectively in detecting influenza A virus infection.  With nasopharyngeal samples, the performance was comparable to RT-PCR.  Although influenza viral load typically decreases with time, the Sofia FIA was sensitive enough to identify influenza infecting patients presenting after several days of illness.  However, a high false positive rate limited the assay's usefulness to identify influenza B virus infection suggesting that the Sofia FIA should not be the sole basis of any clinical decisions or as guidance for anti-viral agent administration. 

The authors stated that this study had several drawbacks.  First, these researchers preformed this prospective cohort study in adults from outpatient clinics and the emergency department.  Some research has reported that the Sofia FIA performed well in young children due to higher viral loads and the relatively immature immune systems of these patients.  The lack of data from young patients in this study may affect the overall performance of the Sofia FIA.  Second, the patients included in this trial presented with mild influenza symptoms.  There were few underlying conditions in the patients and the severity index was not evaluated.  As much lower sensitivity and PPVs were observed in critically ill patients, these findings on the performance of the Sofia FIA may not be applied for the critically ill patients.  Finally, this study was carried out at a single center with a limited number of patients.  Case numbers were further reduced in the subgroup analyses.  The study sample was small, and the low PPV especially influenza B may be due to further reduced number in the subgroup analyses.  However, this trial considered several important clinical parameters that may impact the diagnostic performance of the Sofia FIA.  With all of these clinical parameters defined and included, this report provided critical information to improve test interpretation in a clinical point-of-care setting.  Moreover, these researchers also encouraged similar studies to include relevant clinical perspectives to examine the diagnostic performance of any rapid influenza antigen tests, including the Sofia FIA.

Lee and colleagues (2021) noted that although the Quidel Sofia rapid influenza FIA is widely used to identify influenza A and B, the diagnostic accuracy of this test remains unclear. In a systematic review and meta-analysis, these researchers examined the diagnostic performance of this test compared to RT-PCR.  They carried out a systematic literature search using Medline, Embase, and the Cochrane Central Register.  Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and a hierarchical summary receiver-operating characteristic curve (HSROC) of this test for identifying influenza A and B were determined using meta-analysis.  A sensitivity subgroup analysis was carried out to identify potential sources of heterogeneity within selected studies.  These investigators identified 17 studies involving 8,334 patients.  Pooled sensitivity, specificity, and DOR of the Quidel Sofia rapid influenza FIA for identifying influenza A were 0.78 (95 % CI: 0.71 to 0.83), 0.99 (95 % CI: 0.98 to 0.99), and 251.26 (95 % CI: 139.39 to 452.89), respectively.  Pooled sensitivity, specificity, and DOR of this test for identifying influenza B were 0.72 (95 % CI: 0.60 to 0.82), 0.98 (95 % CI: 0.96 to 0.99), and 140.20 (95 % CI: 55.92 to 351.54), respectively.  The area under the HSROC for this test for identifying influenza A was similar to that for identifying influenza B.  Age was considered a probable source of heterogeneity.  The authors concluded found that pooled sensitivities of the Quidel Sofia rapid influenza FIA were slightly below the target level (greater than or equal to 80 %) set by the FDA for both influenza A and B; thus, physicians should consider the possibility of false-negative results by this test, especially for adults.  Although pooled specificities of this test were very high for both influenza A and B, substantial between-study heterogeneity requires careful interpretation of the data.

The authors stated that this was the 1st meta-analysis to examine the Quidel Sofia rapid influenza FIA for detecting influenza.  However, potential limitations of this study should be considered when interpreting these findings.  First, because this review/analysis was based on a relatively small number of trials, these findings should be carefully interpreted due to its limited statistical power.  Second, these researchers could not make an assessment for publication bias since no reliable methods existed to examine this issue for diagnostic test accuracy studies.  Finally, as a sample for viral diagnosis, nasopharyngeal aspirates could show higher quality than nasopharyngeal swabs.  As mentioned previously, although these investigators tried to examine the diagnostic accuracy of the Quidel Sofia rapid influenza FIA according to the type of samples, they were unable to carry out such analysis because of data limitations.

Phetcharakupt and associates (2021) stated that rapid influenza diagnostic test (RIDT) is a diagnostic tool that detects the influenza virus nucleoprotein antigen.  The RIDT is widely used in clinical practice because it is simple and cost-effective; and provides results within 10 to 15 mins.  In a retrospective study, these investigators examined the sensitivity and specificity of the Sofia RIDT compared with the Luminex multiplex PCR.  The secondary objective was to determine the predicting factors for diagnosing influenza among individuals with ILI.  These investigators examined patients with ILI who had the results of both tests; they determined the performances of the RIDT.  A total of 473 patients were included with a median age of 58 (inter-quartile range [IQR] 41 to 74) years.  Of these, 47.1 % were male, and 16.2 % were diagnosed with influenza by the RIDT or RT-PCR's positive test.  For influenza A, the RIDT showed a sensitivity of 76.3 % (95 % CI: 59.8 to 88.6) and a specificity of 97.9 % (95 % CI: 96.1 to 99.0), whereas for influenza B, it showed a sensitivity of 47.1 % (95 % CI: 23.0 to 72.2) and a specificity of 97.1 % (95 % CI: 95.2 to 98.5).  Patients with influenza were more likely to present with fever (81.8 % versus 63.1 %), cough (81.8 % versus 66.1 %), and rhinorrhea (41.6 % versus 26.5 %) compared to those without influenza (p < 0.05, all), and had a higher proportion of pneumonia (19.5 % versus 10.6 %, p = 0.029) and acute respiratory distress syndrome (5.2 % versus 1.5 %, p = 0.063).  The predicting factors for influenza among patients presented with ILI were cough (odds ratio [OR] 2.77; 95 % CI: 0.21 to 0.81, p = 0.010), rhinorrhea (OR 1.87; 95 % CI: 1.03 to 3.36, p = 0.037), and higher body temperature (OR 1.64; 95 % CI: 1.23 to 2.19, p = 0.001).  The authors concluded that the sensitivity of the RIDT for the diagnosis of influenza was fair in contrast to the specificity.  Among patients with ILI, cough, rhinorrhea, and higher body temperature might be factors for predicting influenza.

The authors stated that this study had several drawbacks.  First, unavailable medical records and missing data such as a history of receiving influenza vaccine are common due to the retrospective study's nature.  Second, this study was conducted in a single center; thus, the findings might not be generalized to other populations or other settings.  The low prevalence of influenza B in this trial might have affected the performance of RIDT.  However, this study's benefit was evaluating the parameter(s) associated with a diagnosis of influenza, which might aid a physician in decision-making regarding the diagnosis and treatment of influenza in a situation where any confirmation test could not be performed.

Gentilotti et al (2022) stated that point-of-care (POC) tests could be essential in differentiating bacterial and viral acute community-acquired lower respiratory tract infections and driving antibiotic stewardship in the community.  In a systematic review and meta-analysis, these investigators examined diagnostic test accuracy of POC tests in the community setting for acute community-acquired lower respiratory tract infections.  Data sources included multiple databases (Medline, Embase, Web of Science, Cochrane Library, Open Gray) from inception to May 31, 2021, without language restrictions.  Diagnostic test accuracy studies entailing patients at primary care, out-patient clinic, emergency department and long-term care facilities with a clinical suspicion of acute community-acquired lower respiratory tract infections were selected for analysis.  The comparator was any test used as a comparison to the index test.  In order not to limit the study inclusion, the comparator was not defined a priori.  A total of 4 reviewers independently extracted data, rated risk of bias, and examined the quality using QUADAS-2.  The measures of diagnostic test accuracy were calculated with 95 % CI.  A total of 421 studies addressed at least 1 POC test.  The diagnostic performance of molecular tests was higher compared with that of rapid diagnostic tests for all the pathogens studied.  The accuracy of stand-alone signs and symptoms or biomarkers was poor.  Lung ultrasound (US) showed high sensitivity and specificity (90 % for both) for the diagnosis of bacterial pneumonia.  Rapid antigen-based diagnostic tests for influenza, respiratory syncytial virus (RSV), human metapneumovirus, and Streptococcus pneumoniae had sub-optimal sensitivity (range of 49 % to 84 %) but high specificity (greater than 80 %).  The authors concluded that physical examination and host biomarkers were not sufficiently reliable as stand-alone tests to differentiate between bacterial and viral pneumonia.  Lung US demonstrated higher accuracy than chest X-ray for bacterial pneumonia at emergency department.  Rapid antigen-based diagnostic tests could not be considered fully reliable because of high false-negative rates.  Overall, molecular tests for all the pathogens considered were found to be the most accurate.


References

The above policy is based on the following references:

  1. Antoniol S, Fidouh N, Ghazali A, et al; Emergency Department study group on respiratory viruses. Diagnostic performances of the Xpert® Flu PCR test and the OSOM® immunochromatographic rapid test for influenza A and B virus among adult patients in the Emergency Department. J Clin Virol. 2018;99-100:5-9.
  2. Betts RF. Influenza virus. In: Principles and Practice of Infectious Diseases. 4th ed. GL Mandell, JE Bennett, R Dolin, eds. New York, NY: Churchill Livingstone; 1995;1546-1567.
  3. Brigadoi G, Gastaldi A, Moi M, et al. Point-of-care and rapid tests for the etiological diagnosis of respiratory tract infections in children: A systematic review and meta-analysis. Antibiotics (Basel). 2022;11(9):1192.
  4. Call SA, Vollenweider MA, Hornung CA, et al. Does this patient have influenza? JAMA. 2005;293(8):987-997.
  5. Cate TR. Influenza. In: Conn’s Current Therapy. 50th ed. RE Rakel, ed. Philadelphia, PA: WB Saunders Co; 1998;90-93.
  6. Centers for Disease Control and Prevention (CDC). Influenza (Flu). Diagnosis. Information for Healthcare Professionals. Atlanta, GA: CDC; updated October 12, 2005. 
  7. Centers for Disease Control and Prevention (CDC). Performance of rapid influenza diagnostic tests during two school outbreaks of 2009 pandemic influenza A (H1N1) virus infection - Connecticut, 2009. MMWR Morb Mortal Wkly Rep. 2009;58(37):1029-1032.
  8. Chartrand C, Leeflang MM, Minion J, et al. Accuracy of rapid influenza diagnostic tests: A meta-analysis. Ann Internal Med. 2012;156(7):500-511.
  9. Cruz AT, Cazacu AC, Greer JM, Demmler GJ. Rapid assays for the diagnosis of influenza A and B viruses in patients evaluated at a large tertiary care children's hospital during two consecutive winter seasons. J Clin Virol. 2008;41(2):143-147.
  10. Cruz AT, Demmler-Harrison GJ, Caviness AC, et al. Performance of a rapid influenza test in children during the H1N1 2009 influenza a outbreak. Pediatrics. 2010;125(3):e645-e650.
  11. de La Rocque F, Lécuyer A, Wollner C, et al. Impact of influenza rapid diagnostic tests (IRDT) on the diagnosis of influenza and on the management of influenza in children in ambulatory pediatric setting. Arch Pediatr. 2009;16(3):288-293.
  12. Dolin R. Diagnosis of seasonal influenza in adults. UpToDate [online serial]. Waltham, MA: UpToDate; reviewed March 2015.
  13. Dolin R. Influenza. In: Harrison’s Principles of Internal Medicine. 14th ed. AS Fauci, E Braunwald, KJ Isselbacher, et al., eds. New York, NY: McGraw-Hill; 1998:1112-1116.
  14. Drexler JF, Helmer A, Kirberg H, et al. Poor clinical sensitivity of rapid antigen test for influenza A pandemic (H1N1) 2009 virus. Emerg Infect Dis. 2009;15(10):1662-1664.
  15. Dugas AF, Coleman S, Gaydos CA, et al. Cost-utility of rapid polymerase chain reaction-based influenza testing for high-risk emergency department patients. Ann Emerg Med. 2013;62(1):80-88.
  16. Effler PV, Ieong MC, Tom T, et al. Enhancing public health surveillance for influenza virus by incorporating newly available rapid diagnostic tests. Emerg Infect Dis. 2002;8(1):23-28.
  17. Gaspard P, Mosnier A, Cohen JM, et al. Immunoassay rapid test for influenza diagnosis in institutions for elderly people: A four-year surveillance with the GROG Géronto-Alsace. Pathol Biol (Paris). 2009;57(1):90-96.
  18. Gentilotti E, De Nardo P, Cremonini E, et al. Diagnostic accuracy of point-of-care tests in acute community-acquired lower respiratory tract infections. A systematic review and meta-analysis. Clin Microbiol Infect. 2022;28(1):13-22.
  19. Ginocchio CC, Lotlikar M, Falk L, et al. Clinical performance of the 3M Rapid Detection Flu A+B Test compared to R-Mix culture, DFA and BinaxNOW Influenza A&B Test. J Clin Virol. 2009;45(2):146-149.
  20. Harper SA, Fukuda K, Uyeki TM, et al. Prevention and control of influenza. Recommendations of the Advisory Committee on Immunization Practices (ACIP). MMWR Recomm Rep. 2005;54(RR-8):1-40.
  21. Hawkes M, Richardson SE, Ipp M, et al. Sensitivity of rapid influenza diagnostic testing for swine-origin 2009 a (H1N1) influenza virus in children. Pediatrics. 2010;125(3):e639-e644.
  22. Hayden FG. Influenza. In: Cecil Textbook of Medicine. 20th ed. JC Bennett, F Plum, eds. Philadelphia, PA: WB Saunders Co; 1996:1753-1757.
  23. Hueston WJ, Benich JJ. A cost-benefit analysis of testing for influenza A in high-risk adults. Ann Family Med. 2004;2(1):33-40.
  24. Hurt AC, Alexander R, Hibbert J, et al. Performance of six influenza rapid tests in detecting human influenza in clinical specimens. J Clin Virol. 2007;39(2):132-135.
  25. Koski RR, Klepser ME. A systematic review of rapid diagnostic tests for influenza: Considerations for the community pharmacist. J Am Pharm Assoc (2003). 2017;57(1):13-19.
  26. Lee J, Song J-U, Kim YH, et al. Diagnostic accuracy of the Quidel Sofia rapid influenza fluorescent immunoassay in patients with influenza-like illness: A systematic review and meta-analysis. Tuberc Respir Dis (Seoul). 2021;84(3):226-236.
  27. Mancini F, Barbanti F, Scaturro M, et al; Istituto Superiore di Sanità (ISS) COVID-19 Team. Multiplex real-time reverse-transcription polymerase chain reaction assays for diagnostic testing of severe acute respiratory syndrome coronavirus 2 and seasonal influenza viruses: A challenge of the phase 3 pandemic setting. J Infect Dis. 2021;223(5):765-774.
  28. Merckx J, Wali R, Schiller I, et al. Diagnostic accuracy of novel and traditional rapid tests for influenza infection compared with reverse transcriptase polymerase chain reaction: A systematic review and meta-analysis. Ann Intern Med. 2017;167(6):394-409.
  29. Mundy L, Parrella A. ZstatFlu: Point-of-care influenza test. Horizon Scanning Prioritising Summary - Volume 7. Adelaide, SA: Adelaide Health Technology Assessment (AHTA) on behalf of National Horizon Scanning Unit (HealthPACT and MSAC); 2004.
  30. Munoz FM. Seasonal influenza in children: Clinical features and diagnosis. UpToDate [online serial]. Waltham, MA: UpToDate; reviewed March 2015.
  31. National Institute for Clinical Excellence (NICE). Guidance on the use of zanamivir, oseltamivir and amantadine for the treatment of influenza. Technology Appraisal No. 58. London, UK: NICE; 2003.
  32. Neuzil KM, Griffin MR, Schaffner W. Influenza vaccine: Issues and opportunities. Infect Dis Clin North Am. 2001;15(1):123-141, ix.
  33. Nicholson KG, Abrams KR, Batham S, et al. Randomised controlled trial and health economic evaluation of the impact of diagnostic testing for influenza, respiratory syncytial virus and Streptococcus pneumoniae infection on the management of acute admissions in the elderly and high-risk 18- to 64-year-olds. Health Technol Assess. 2014;18(36):1-274.
  34. Parida M, Shukla J, Sharma S, et al. Development and evaluation of reverse transcription loop-mediated isothermal amplification assay for rapid and real-time detection of the swine-origin influenza A H1N1 virus. J Mol Diagn. 2011;13(1):100-107.
  35. Paulson J. 3M Rapid Detection Flu A + B Test: A new diagnostic test for rapid detection of influenza A and influenza B. Mol Diagn Ther. 2009;13(1):15-18.
  36. Phetcharakupt V, Pasomsub E, Kiertiburanakul S. Clinical manifestations of influenza and performance of rapid influenza diagnostic test: A university hospital setting. Health Sci Rep. 2021;4(4):e408.
  37. Poehling KA, Edwards KM. Prevention, diagnosis, and treatment of influenza: Current and future options. Curr Opin Pediatr. 2001;13(1):60-64.
  38. Poehling KA, Zhu Y, Tang YW, Edwards K. Accuracy and impact of a point-of-care rapid influenza test in young children with respiratory illnesses. Arch Pediatr Adolesc Med. 2006;160(7):713-718.
  39. Quattrocchi M, Campa A, Guido M, De Donno A. Evaluation of a rapid diagnostic test for influenza viruses A and B. Ig Sanita Pubbl. 2010;66(3):345-356.
  40. Rodriguez WJ, Schwartz RH, Thorne MM. Evaluation of diagnostic tests for influenza in a pediatric practice. Pediatr Infect Dis J. 2002;21(3):193-196.
  41. Smit M, Beynon KA, Murdoch DR, Jennings LC. Comparison of the NOW Influenza A & B, NOW Flu A, NOW Flu B, and Directigen Flu A+B assays, and immunofluorescence with viral culture for the detection of influenza A and B viruses. Diagn Microbiol Infect Dis. 2007;57(1):67-70.
  42. Su LC, Chang CM, Tseng YL, et al. Rapid and highly sensitive method for influenza A (H1N1) virus detection. Anal Chem. 2012;84(9):3914-3920.
  43. Treanor JJ Hall CB. Influenza and infections of the trachea, bronchi, and bronchioles. In: Practical Approach to Infectious Diseases. 4th ed. RE Reese, RF Betts, eds. Philadelphia, PA: Lippincott-Raven Publishers; 1996:240-246.
  44. Uyeki TM. Influenza diagnosis and treatment in children: A review of studies on clinically useful tests and antiviral treatment for influenza. Pediatr Infect Dis J. 2003;22(2):164-177.
  45. Vega R. Rapid viral testing in the evaluation of the febrile infant and child. Curr Opin Pediatr. 2005;17(3):363-367.
  46. Vemula SV, Zhao J, Liu J, et al. Current approaches for diagnosis of influenza virus infections in humans. Viruses. 2016;8(4):96.
  47. Vos LM, Bruning AHL, Reitsma JB, et al. Rapid molecular tests for influenza, respiratory syncytial virus, and other respiratory viruses: A systematic review of diagnostic accuracy and clinical impact studies. Clin Infect Dis. 2019;69(7):1243-1253.
  48. Wabe N, Li L, Lindeman R, et al. The impact of rapid molecular diagnostic testing for respiratory viruses on outcomes for emergency department patients. Med J Aust. 2019;210(7):316-320.
  49. Wright P. Influenza viral infections. In: Nelson Textbook of Pediatrics. 15th ed. RE Behrman, RM Kliegman, AM Arvin, eds. Philadelphia, PA: WB Saunders Co; 1996;901-903.
  50. Yang J-H, Huang P-Y, Shie S-S, et al. Diagnostic performance of the Sofia® influenza A+B fluorescent immunoassay in adult outpatients in Northern Taiwan. J Med Virol. 2018;90(6):1010-1018.
  51. Yoon J, Yun SG, Nam J, et al. The use of saliva specimens for detection of influenza A and B viruses by rapid influenza diagnostic tests. J Virol Methods. 2017;243:15-19.