Cardiovascular Monitoring Equipment for Home Use: Pulse, Blood Pressure, Telemonitors, and Pacemaker Monitors

Number: 0548

Table Of Contents

Policy
Applicable CPT / HCPCS / ICD-10 Codes
Background
References


Policy

Scope of Policy

This Clinical Policy Bulletin addresses cardiovascular monitoring equipment for home use: pulse, blood pressure, telemonitors, and pacemaker monitors.

  1. Medical Necessity

    1. Pacemaker Monitors

      Aetna considers self-contained pacemaker monitors medically necessary for members with cardiac pacemakers.  These include the following types:

      1. Audible/visible signal pacemaker monitors -- these devices produce an audible and visible signal that indicates the pacemaker rate. 
      2. Digital electronic pacemaker monitors -- these devices provide the member with an instantaneous digital readout of his/her pacemaker pulse rate.

      A specialized telephone attachment for trans-telephonic transmission of pacemaker monitoring results is also considered medically necessary.  The Pace Trac is an example of a pacemaker monitor currently on the market.

      A pacemaker controls cardiac arrhythmias by repeated electrical stimulation of the heart.  Pacemaker monitoring equipment is needed to detect impending battery failure and to monitor the performance of the pacemaker.  The design of the self-contained pacemaker monitor makes it possible for the member to monitor his or her pacemaker periodically and minimizes the need for regular visits to the outpatient department of the provider.

    2. Blood Pressure Monitors and Stethoscopes

      Aetna considers validated home blood pressure monitors a medically necessary alternative to ambulatory blood pressure monitoring to confirm the diagnosis of hypertension in persons age 18 years of age and older who have elevated blood pressure readings in the office (greater than 140 systolic or 90 diastolic) and the following criteria are met:
      1. the blood pressure cuff is prescribed by a physician; and
      2. arm devices only; and
      3. correct cuff size assessed and provided by the vendor; and
      4. only one blood pressure cuff considered medically necessary per 5 years.

      In addition, Aetna considersers validated blood pressure monitors medically necessary for members receiving hemodialysis or peritoneal dialysis in the home.  In addition, validated blood pressure cuffs are considered medically necessary DME for members with hypertension.

  2. Experimental and Investigational

    The following procedures are considered experimental and investigational because the effectiveness of these approaches has not been established:

    1. AngelMed Guardian intracardiac ischemia monitoring device 
    2. Automated oscillometer serial blood pressure monitors (e.g., Dinamap and BpTRU) for home use 
    3. CardioMems pillow and other components associated with CardioMems
    4. Home congestive heart failure telemonitoring devices 
    5. Implantable congestive heart failure monitors (e.g., the Chronicle IHM System) 
    6. Implantable wireless pulmonary artery pressure monitor (CardioMems) for heart failure and all other indications.
    7. Non-invasive assessment of central blood pressure (e.g., SphygmoCor System) 
    8. Zoll Heart Failure and Arrhythmia Management System (HFAMS) for monitoring pulmonary fluid levels as an early indicator for heart failure decompensation.
  3. Policy Limitations and Exclusions

    Pulse Tachometers

    Pulse tachometers (pulse rate monitors, heart rate monitors) do not meet Aetna’s definition of covered durable medical equipment (DME) in that they are not primarily medical in nature and are normally of use in the absence of illness or injury.  Examples of brand names of pulse tachometers include the Exersentry, the Insta-Pulse, and the MacLevy Omni Pulse.

  4. Related Policies


Table:

CPT Codes / HCPCS Codes / ICD-10 Codes

Code Code Description

Information in the [brackets] below has been added for clarification purposes.   Codes requiring a 7th character are represented by "+":

Congestive Heart Failure Telemonitoring:

CPT codes not covered for indications listed in the CPB:

Invasive Congestive Heart Failure Monitoring:

CPT codes not covered for indications listed in the CPB:

0525T - 0532T Insertion or replacement of intracardiac ischemia monitoring system
33289 Transcatheter implantation of wireless pulmonary artery pressure sensor for long-term hemodynamic monitoring, including deployment and calibration of the sensor, right heart catheterization, selective pulmonary catheterization, radiological supervision and interpretation, and pulmonary artery angiography, when performed
93264 Remote monitoring of a wireless pulmonary artery pressure sensor for up to 30 days, including at least weekly downloads of pulmonary artery pressure recordings, interpretation(s), trend analysis, and report(s) by a physician or other qualified health care professional

HCPCS codes not covered for indications listed in the CPB:

C1833 Monitor, cardiac, including intracardiac lead and all system components (implantable)
C2624 Implantable wireless pulmonary artery pressure sensor with delivery catheter, including all system components

Self-contained Pacemaker Monitors:

CPT codes covered if selection criteria are met:

93279 Programming device evaluation with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with physician analysis, review and report; single lead pacemaker system
93280     dual lead pacemaker system
93281     multiple lead pacemaker system
93282     single lead transvenous implantable defibrillator system
93283     dual lead transvenous implantable defibrillator system
93284     multiple lead transvenous implantable defibrillator system
93286 Peri-procedural device evaluation and programming of device system parameters before or after a surgery, procedure, or test with physician analysis, review and report; single, dual, or multiple lead pacemaker system
93287     single, dual, or multiple lead implantable defibrillator system
93288 Interrogation device evaluation (in person) with physician analysis, review and report, includes connection, recording and disconnection per patient encounter; single, dual, or multiple lead pacemaker system
93289     single, dual, or multiple lead transvenous implantable defibrillator system, including analysis of heart rhythm derived data elements
93290     implantable cardiovascular monitor system, including analysis of 1 or more recorded physiologic cardiovascular data elements from all internal and external sensors
93292     wearable defibrillator system
93293 Transtelephonic rhythm strip pacemaker evaluation(s) single, dual, or multiple lead pacemaker system, includes recording with and without magnet application with physician analysis, review and report(s), up to 90 days
93294 Interrogation device evaluation(s) (remote), up to 90 days; single, dual, or multiple lead pacemaker system with interim physician analysis, review(s) and report(s)
93295      single, dual, or multiple lead implantable defibrillator system with interim analysis, review(s) and report(s) by a physician or other qualified health care professional
93296     single, dual, or multiple lead pacemaker system or implantable defibrillator system, remote data acquisition(s), receipt of transmissions and technician review, technical support and distribution of results
93297 Interrogation device evaluation(s) (remote), up to 30 days; implantable cardiovascular monitor system, including analysis of 1 or more recorded physiologic cardiovascular data elements from all internal and external sensors, physician analysis, review(s) and report(s)

HCPCS codes covered if selection criteria are met:

E0610 Pacemaker monitor, self-contained, (checks battery depletion, includes audible and visible check systems)
E0615 Pacemaker monitor, self-contained, checks battery depletion and other pacemaker components, includes digital/visible check systems

ICD-10 codes covered if selection criteria are met:

I46.2 - I49.9
R00.1
Cardiac dysrhythmias
Z95.0 Presence of cardiac pacemaker

Pulse Tachometers - no specific codes:

Blood Pressure Monitors and Stethoscopes [only validated devices]:

Other CPT codes related to the CPB:

90935 - 90937 Hemodialysis

HCPCS codes covered if selection criteria are met:

A4660 Sphygmomanometer / blood pressure apparatus with cuff and stethoscope
A4663 Blood pressure cuff only
A4670 Automatic blood pressure monitor

ICD-10 codes covered if selection criteria are met:

I10 Essential primary hypertension [not covered for under age 18]
I12.0 Hypertensive chronic kidney disease with stage 5 chronic kidney disease or end stage renal disease
I13.11 - I13.2 Hypertensive heart and chronic kidney disease [without heart failure and with stage 5 chronic kidney disease or end stage renal disease and with heart failure and with stage 5 chronic kidney disease, or end stage renal disease]
N17.0 - N19 Acute kidney failure and chronic kidney disease
O10.011 - O11.9
O13.1 - O16.9
Proteinuria and hypertensive disorders in pregnancy, childbirth and the puerperium
R03.0 Elevated blood-pressure reading, without diagnosis of hypertension [not covered for under age 18]
Z99.2 Dependence on renal dialysis

Noninvasive assessment of central blood pressure (SphygmoCor System):

CPT codes not covered for indications listed in the CPB:

93050 Arterial pressure waveform analysis for assessment of central arterial pressures, includes obtaining waveform(s), digitization and application of nonlinear mathematical transformations to determine central arterial pressures and augmentation index, with interpretation and report, upper extremity artery, non-invasive

Intracardiac Ischemia Monitoring Devices (AngelMed Guardian):

Zoll Heart Failure and Arrhythmia Management System (HFAMS):

CPT codes not covered for indications listed in the CPB:

0607T Remote monitoring of an external continuous pulmonary fluid monitoring system, including measurement of radiofrequency-derived pulmonary fluid levels, heart rate, respiration rate, activity, posture, and cardiovascular rhythm (eg, ECG data), transmitted to a remote 24-hour attended surveillance center; set-up and patient education on use of equipment
0608T     analysis of data received and transmission of reports to the physician or other qualified health care professional

Background

Congestive Heart Failure Telemonitoring

Non-invasive telemonitoring for congestive heart failure involves the trans-telephonic transmission of weight, blood pressure (BP), heart rate (HR) and rhythm to a remote monitoring center.  The Trans-European Network-Home-Care Management System (TEN-HMS) study is a randomized controlled clinical trial comparing home telemonitoring (HTM) to nurse telephone support (NTS) and usual care (UC) for patients with heart failure who are at high-risk of hospitalization or death.  The study found that patients assigned to HTM did not have significantly fewer days dead or hospitalized (the primary study endpoint) than patients assigned to NTS or UC.  In this study, 426 patients recruited from hospitals in the Netherlands, the United Kingdom, and Germany with a recent (within the past 6 weeks) hospital admission for heart failure and left ventricular ejection fraction (LVEF) less than 40 % were assigned randomly to HTM, NTS, or UC in a 2:2:1 ratio.  Patients were taking at least 40 mg per day of furosemide or equivalent, and at least 1 marker of increased risk.  Home telemonitoring consisted of twice-daily patient self-measurement of weight, BP, HR, and rhythm with automated devices linked to a cardiology center.  The NTS consisted of specialist nurses who were available to patients by telephone.  Primary care physicians delivered UC.  The primary end point was days dead or hospitalized with NTS versus HTM at 240 days.  The investigators reported that, during 240 days of follow-up, there was no statistically significant difference in the days that were lost as the result of death or hospitalization for UC, NTS, and HTM.  The number of admissions and mortality were similar among patients randomly assigned to NTS or HTM, but the mean duration of admission was less in patients assigned to HTM.  The investigators concluded that “[f]urther investigation and refinement of the application of HTM are warranted because it may be a valuable role for the management of selected patients with heart failure.”

Heart failure guidelines from the National Institute for Clinical Excellence (2003) stated that “[m]ore complex remote monitoring (such as telemonitoring) of patients with heart failure is in its infancy, but shows promise for the future.”

In a systematic review, Chaudhry et al (2007) examined the evidence on telemonitoring in patients with chronic heart failure.  Interventions included telephone-based symptom monitoring (n = 5), automated monitoring of signs and symptoms (n = 1), and automated physiologic monitoring (n = 1).  Two studies directly compared effectiveness of 2 or more forms of telemonitoring.  Study quality and intervention type varied considerably.  Six studies suggested reduction in all-cause and heart failure hospitalizations (14 % to 55 % and 29 % to 43 %, respectively) or mortality (40 % to 56 %) with telemonitoring.  Of the 3 negative studies, 2 enrolled low-risk patients and patients with access to high quality care, whereas 1 enrolled a very high-risk Hispanic population.  Studies comparing forms of telemonitoring demonstrated similar effectiveness.  However, intervention costs were higher with more complex  programs (8,383 dollars per patient per year) versus less complex programs (1,695 dollars per patient per year).  The authors concluded that the evidence base for telemonitoring in heart failure is currently quite limited.  Furthermore, an editorial published in the British Medical Journal (Grancelli and Ferrante, 2007), which addressed another systematic evidence review found similar results with simple telephone interventions compared to complex congestive heart failure telemonitoring.

Dang et al (2009) evaluated the evidence base for the use of home telehealth remote monitoring in elderly with congestive heart failure (CHF).  The search was restricted to randomized controlled trials using either automated monitoring of signs and symptoms or automated physiologic monitoring.  For this review, telephone-based monitoring of signs and symptoms was not considered remote monitoring.  Studies were also excluded if they did not present outcomes related to healthcare utilization.  A total of 9 studies met selection criteria, with interventions that varied greatly.  Four 3-arm studies directly compared the effectiveness of 2 different interventions to usual care.  Six of the 9 studies suggested a 27 % to 40 % reduction in overall admissions.  Two 2-arm studies demonstrated a 40 % to 46 % reduction in HF-related admissions while 2 other 3-arm studies showed similar trends; however, this was not statistically significant.  Three of 9 studies suggested a significant reduction in mortality (30 % to 67 %) and 3 studies showed significant reduction in healthcare utilization costs.  Two studies suggested a 53 % to 62 % reduction in bed days of care.  Two studies showed significant reduction in the number of Emergency Department visits.  Three 2-arm studies and 1 3-arm study demonstrated significant overall improvement in outcomes with use of telemonitoring.  Available data suggest that telemonitoring is a promising strategy.  The authors stated that more data are needed to determine the ideal patient population, technology, and parameters, frequency and duration of telemonitoring, and the exact combination of case management and close monitoring that would assure consistent and improved outcomes with cost reductions in CHF.

Mortara and co-workers (2009) assessed the feasibility of a new system of HTM. The HTM system was used to monitor clinical and physiological parameters, and its effectiveness (compared with usual care) in reducing cardiac events in heart failure (HF) patients was evaluated.  Measurements were patient-managed.  From 2002 to 2004, a total of 461 HF patients (age 60 +/- 11 years, New York Heart Association class 2.4 +/- 0.6, left ventricular ejection fraction 29 +/- 7 %) were enrolled at 11 centers and randomized (1:2) to either usual outpatient care or HTM administered as 3 randomized strategies:
  1. monthly telephone contact;
  2. strategy 1 plus weekly transmission of vital signs; and
  3. strategy 2 plus monthly 24-hr recording of cardiorespiratory activity.
Patients completed 81 % of vital signs transmissions, as well as 92 % of cardio-respiratory recordings.  Over a 12-month follow-up, there was no significant effect of HTM in reducing bed-days occupancy for HF or cardiac death plus HF hospitalization.  Post-hoc analysis revealed a heterogeneous effect of HTM in the 3 countries (Italy, Poland, and the United Kingdom) with a trend towards a reduction of events in Italy.  The authors concluded that Home or Hospital in Heart Failure Study indicated that self-managed HTM of clinical and physiological parameters is feasible in HF patients, with surprisingly high compliance.  Whether HTM contributes to a reduction of cardiac events requires further investigation.

Schmidt and colleagues (2010) reviewed the current status of health services research on telemonitoring, focusing on patients with chronic CHF.  The Medline database was selectively searched for articles appearing from June 2001 to May 2008, with an emphasis on randomized, controlled trials.  The available scientific data on vital signs monitoring are limited, yet there is evidence for a positive effect on some clinical endpoints, particularly mortality.  However, any possible improvement of patient-reported outcomes, such as the quality of life, still remains to be demonstrated.  The authors concluded that these findings suggested that telemonitoring is effective, yet there is no evidence for superior outcomes with any particular model of care incorporating telemonitoring (i.e., monitoring of vital signs versus structured telephone monitoring).  A valid criticism is that the individual components of HTM have not yet been separately tested in order to compare their individual effects.

Polisena and associates (2010) conducted a systematic review of the literature about HTM compared with usual care.  An electronic literature search was conducted to identify studies of HTM use in CHF patients.  A total of 21 original studies on HTM for patients with CHF were included (n = 3,082).  A random effects model was used to compute treatment effectiveness to measure the average effect of the intervention across all studies where the quantitative pooling of results was appropriate.  Home telemonitoring reduced mortality (risk ratio = 0.64; 95 % confidence interval [CI]: 0.48 to 0.85) compared with usual care.  Several studies suggested that HTM also helped to lower the number of hospitalizations and the use of other health services.  Patient quality of life and satisfaction with HTM were similar or better than with usual care.  Moreover, the authors stated that more studies of higher methodological quality are needed to provide more precise information regarding the potential clinical effectiveness of home telehealth interventions.

Koehler et al (2011) examined if physician-led remote telemedical management (RTM) compared with usual care would result in reduced mortality in ambulatory patients with CHF.  A total of 710 stable CHF patients in New York Heart Association (NYHA) functional class II or III with a LVEF of less than or equal to 35 % and a history of HF decompensation within the previous 2 years or with a LVEF of less than or equal to 25 % were enrolled in this study.  Patients were randomly assigned (1:1) to RTM or usual care.  Remote telemedical management used portable devices for electrocardiogram (ECG), BP, and body weight measurements connected to a personal digital assistant that sent automated encrypted transmission via cell phones to the telemedical centers.  The primary end point was death from any cause.  The first secondary end point was a composite of cardiovascular death and hospitalization for HF.  Baseline characteristics were similar between the RTM (n = 354) and control (n = 356) groups.  Of the patients assigned to RTM, 287 (81 %) were at least 70 % compliant with daily data transfers and no break for greater than 30 days (except during hospitalizations).  The median follow-up was 26 months (minimum 12), and was 99.9 % complete.  Compared with usual care, RTM had no significant effect on all-cause mortality (hazard ratio, 0.97; 95 % CI: 0.67 to 1.41; p = 0.87) or on cardiovascular death or HF hospitalization (hazard ratio, 0.89; 95 % CI, 0.67 to 1.19; p = 0.44).  The authors concluded that in ambulatory patients with CHF, RTM compared with usual care was not associated with a reduction in all-cause mortality.

A systematic evidence review (Molloy et al, 2012) examined interventions to enhance adherence to medications in patients with heart failure identified randomized controlled studies of intensified interventions. The review found that all of the six studies of intensified patient care that used direct patient contact intervention showed a significant positive effect on adherence. However, of the five studies of intensified patient  that used telephone or telemonitoring programs, only one led to increased adherence.

An assessment by the California Technology Assessment Forum (Tice, 2011) found that home telemonitoring for patients with heart failure does not meet CTAF TA Criterion 3 through 5 for safety, effectiveness and improvement in health outcomes. CTAF's systematic review of the literature identified 17 trials that randomized 6352 patients to evaluate the efficacy of home telemonitoring. The settings, patient populations, interventions, control groups, outcomes and length of follow-up varied widely between the studies. Because of the heterogeneity in the trials and their outcomes,CTAF performed no formal metaanalysis. The CTAF assessment noted that two large, high quality trials that randomized 2363 patients were published near the time of the CTAF assessment (Tele-HF, TIM-HF) (citing Chaudhry, et al., 2010 and Koehler, et al., 2011). CTAF noted that neither study found any benefit to home monitoring compared with usual care. Mortality was 11% in both groups in one study and 15% in both groups in the other study. In both studies, hospitalization rates were slightly higher in the home telemonitoring groups (Tele-HF 49% versus 47%; TIM-HF 44% versus 39%). The CTAF assessment observed that there were not even trends in favor of home telemonitoring. At the time of the CTAF assessment, there are at least two additional large studies that have yet to be published (TEHAF, OptiLink-HF); the CTAF assessment noted that preliminary results from one of the studies were negative. The CTAF assessment noted that the strongly positive findings in some of the randomized trials suggest that there are subgroups of patients with HF who benefit from some form of telemonitoring. The CTAF assessment stated, however, that the published literature to date does not clearly identify which patients are mostlikely to benefit and what combination of home monitoring technologies are required to obtain optimal results.

Kitsiou et al (2013) evaluated the methodology, quality, and reporting characteristics of prior reviews that have investigated the effects of HTM interventions in the context of chronic diseases.  Ovid MEDLINE, the Database of Abstract of Reviews of Effects (DARE), and Health Technology Assessment Database (HTA) of the Cochrane Library were electronically searched to find relevant systematic reviews, published between January 1966 and December 2012.  Potential reviews were screened and assessed for inclusion independently by 3 reviewers.  Data pertaining to the methods used were extracted from each included review and examined for accuracy by 2 reviewers.  A validated quality assessment instrument, R-AMSTAR, was used as a framework to guide the assessment process.  A total of 24 reviews, 9 of which were meta-analyses, were identified from more than 200 citations.  The bibliographic search revealed that the number of published reviews has increased substantially over the years in this area and although most reviews focus on studying the effects of HTM on patients with CHF, researcher interest has extended to other chronic diseases as well, such as diabetes, hypertension, chronic obstructive pulmonary disease, and asthma.  Nevertheless, an important number of these reviews appear to lack optimal scientific rigor due to intrinsic methodological issues.  Also, the overall quality of reviews did not appear to have improved over time.  While several criteria were met satisfactorily by either all or nearly all reviews, such as the establishment of an a priori design with inclusion and exclusion criteria, use of electronic searches on multiple databases, and reporting of studies characteristics, there were other important areas that needed improvement.  Duplicate data extraction, manual searches of highly relevant journals, inclusion of gray and non-English literature, assessment of the methodological quality of included studies and quality of evidence were key methodological procedures that were performed infrequently.  Furthermore, certain methodological limitations identified in the synthesis of study results have affected the results and conclusions of some reviews.  The authors concluded that despite the availability of methodological guidelines that can be utilized to guide the proper conduct of systematic reviews and meta-analyses and eliminate potential risks of bias, this knowledge has not yet been fully integrated in the area of HTM.  Moreover, they stated that further efforts should be made to improve the design, conduct, reporting, and publication of systematic reviews and meta-analyses in this area.

Pandor and colleagues (2013) examined the clinical effectiveness and cost-effectiveness of HTM or structured telephone support (STS) strategies compared with usual care for adult patients who have been recently discharged (within 28 days) from acute care after a recent exacerbation of HF.  A total of 14 electronic databases (including MEDLINE, EMBASE, PsycINFO and The Cochrane Library) and research registers were searched to January 2012, supplemented by hand-searching relevant articles and contact with experts.  The review included randomized controlled trials (RCTs) or observational cohort studies with a contemporaneous control group that included the following remote monitoring (RM) interventions:
  1. TM (including cardiovascular implanted monitoring devices) with medical support provided during office hours or 24/7;
  2. STS programs delivered by human-to-human contact (HH) or human-to-machine interface (HM).
A systematic review and network meta-analysis (where appropriate) of the clinical evidence was carried out using standard methods.  A Markov model was developed to evaluate the cost-effectiveness of different RM packages compared with usual care for recently discharged HF patients.  Tele-monitoring 24/7 or using cardiovascular monitoring devices was not considered in the economic model because of the lack of data and/or unsuitability for the United Kingdom (UK) setting.  Given the heterogeneity in the components of usual care and RM interventions, the cost-effectiveness analysis was performed using a set of costing scenarios designed to reflect the different configurations of usual care and RM in the UK.  The literature searches identified 3,060 citations; 6 RCTs met the inclusion criteria and were added to the 15 trials identified from the previous systematic reviews giving a total of 21 RCTs included in the systematic review.  No trials of cardiovascular implanted monitoring devices or observational studies met the inclusion criteria.  The methodological quality of the studies varied widely and reporting was generally poor.  Compared with usual care, RM was beneficial in reducing all-cause mortality for STS HH [hazard ratio (HR) 0.77, 95 % credible interval (CrI): 0.55 to 1.08], TM during office hours (HR 0.76, 95 % CrI: 0.49 to 1.18) and TM 24/7 (HR 0.49, 9 5% CrI: 0.20 to 1.18); however, these results were statistically inconclusive.  The results for TM 24/7 should be treated with caution because of the poor methodological quality of the only included study in this network.  No favorable effect on mortality was observed with STS HM.  Similar reductions were observed in all-cause hospitalizations for TM interventions, whereas STS interventions had no major effect.  A sensitivity analysis, in which a study was excluded because it provided better-than-usual support to the control group, showed larger beneficial effects for most outcomes, particularly for TM during office hours.  In the cost-effectiveness analyses, TM during office hours was the most cost-effective strategy with an estimated incremental cost-effectiveness ratio (ICER) of £11,873 per quality-adjusted life-year (QALY) compared with usual care, whereas STS HH had an ICER of £228,035 per QALY compared with TM during office hours.  Structured telephone support HM was dominated by usual care.  Similar results were observed in scenario analyses performed using higher costs of usual care, higher costs of STS HH and lower costs of TM during office hours.  The authors concluded that despite wide variation in usual care and RM strategies, cost-effectiveness analyses suggested that TM during office hours was an optimal strategy (in most costing scenarios).  However, clarity was lacking among descriptions of the components of RM packages and usual care and there was a lack of robust estimation of costs.  They stated that further research is needed in these areas.
Kitsiou and colleagues (2015) evaluated existing evidence from multiple systematic reviews on the effectiveness of home telemonitoring interventions for patients with CHF to inform policy makers, practitioners, and researchers. A comprehensive literature search was performed on Medline, Embase, Cinahl, and the Cochrane Library to identify all relevant, peer-reviewed systematic reviews published between January 1996 and December 2013.  Reviews were searched and screened using explicit keywords and inclusion criteria.  Standardized forms were used to extract data and the methodological quality of included reviews was appraised using the AMSTAR (assessing methodological quality of systematic reviews) instrument.  Summary of findings tables were constructed for all primary outcomes of interest, and quality of evidence was graded by outcome using the GRADE (Grades of Recommendation, Assessment, Development, and Evaluation) system.  Post-hoc analysis and subgroup meta-analyses were conducted to gain further insights into the various types of home telemonitoring technologies included in the systematic reviews and the impact of these technologies on clinical outcomes.  A total of 15 reviews published between 2003 and 2013 were selected for meta-level synthesis.  Evidence from high-quality reviews with meta-analysis indicated that taken collectively, home telemonitoring interventions reduced the relative risk of all-cause mortality (0.60 to 0.85) and heart failure-related hospitalizations (0.64 to 0.86) compared with usual care.  Absolute risk reductions ranged from 1.4 % to 6.5 % and 3.7 % to 8.2 %, respectively.  Improvements in HF-related hospitalizations appeared to be more pronounced in patients with stable HF: HR 0.70 (95 % CI: 0.34 to 1.5]).  Risk reductions in mortality and all-cause hospitalizations appeared to be greater in patients who had been recently discharged (less than or equal to 28 days) from an acute care setting after a recent HF exacerbation: HR 0.62 (95 % CI: 0.42 to 0.89) and HR 0.67 (95 % CI: 0.42 to 0.97), respectively.  However, quality of evidence for these outcomes ranged from moderate-to-low suggesting that further research is very likely to have an important impact on the confidence in the observed estimates of effect and may change these estimates.  The post-hoc analysis identified 5 main types of non-invasive telemonitoring technologies included in the systematic reviews:
  1. video-consultation, with or without transmission of vital signs,
  2. mobile telemonitoring,
  3. automated device-based telemonitoring,
  4. interactive voice response, and
  5. Web-based telemonitoring.

Of these, only automated device-based telemonitoring and mobile telemonitoring were effective in reducing the risk of all-cause mortality and HF-related hospitalizations.  More research data are needed for interactive voice response systems, video-consultation, and Web-based telemonitoring to provide robust conclusions about their effectiveness.  The authors concluded that future research should focus on understanding the process by which home telemonitoring works in terms of improving outcomes, identify optimal strategies and the duration of follow-up for which it confers benefits, and further investigate whether there is differential effectiveness between chronic HF patient groups and types of home telemonitoring technologies.

Athilingam and associates (2018) noted that HF causes significant symptom burden and human suffering with considerable economic burden due to hospital re-admissions.  Targeted interventions to encourage and support self-management behavior is needed.  These researchers tested the proof-of-concept (POC) of a mobile application (HeartMapp) in improving self-care management of patients with HF.  An exploratory inquiry used a field study strategy with purposeful sampling and constant comparative analysis to test the POC of HeartMapp using the Business Model Canvas framework.  A total of 125 individuals, who were identified as potential candidates to use the HeartMapp completed the interview over a 7-week period in 2016.  Constant comparative analysis indicated themes that skilled nursing facilities (SNFs) had increased re-admissions.  Participants from SNFs reported concern on lack of staffing, star rating, and mal-practice claims.  Two types of patients were identified as early adapters of technology and those in denial.  Health care facilities reported challenges on transitional care, nurses struggle with engagement of patients on self-care management.  To avoid re-admission penalty, hospitals task home care agencies to keep the patients home for 30-days.  While home care agencies rely on remote tele-monitoring reported that current tele-monitoring devices are costly to maintain, thus exploring novel technology.  The authors concluded that the Business Model Canvas provided directions for future testing of HeartMapp for its usability as an adjunct device in home health setting to improve self-management and enhance communication with providers, and ultimately reduce re-admissions in patients with HF.

Invasive Congestive Heart Failure Monitoring

Implantable hemodynamic monitoring devices have features that allow remote monitoring of hemodynamic data in patients with HF.  The Chronicle Implantable Hemodynamic Monitor (IHM) is approximately the size of a pacemaker.  The device consists of an implantable monitor and a transvenous lead carrying a pressure sensor.  The pressure-sensing lead continuously measures intra-cardiac pressure, body temperature, physical activity, and HR.  It contains integrated circuitry, a lithium silver vanadium oxide battery with an approximate life of 3 years, and a bi-directional telemetry transmission coil hermetically sealed in a titanium can.  The Chronicle IHM has an investigational device exemption in the United States, which allows use of the device in clinical trials.

Bourge et al (2008) reported on the outcomes of the COMPASS-HF (Chronicle Offers Management to Patients with Advanced Signs and Symptoms of Heart Failure) study, a randomized, single-blinded, multi-center controlled study of the Chronicle IHM in 274 persons with NYHA class III or IV CHF.  All study subjects had an emergency room visit or at least 1 prior HF-related hospitalization within 6 months of entering the study.  The 274 successfully implanted patients were randomized to receive either optimal medical care alone (n = 140) or optimal medical care guided by results from hemodynamic measurements provided by the Chronicle IHM (n = 134).  For the first 6 months, all IHM patients transmitted monitoring data weekly.  Physicians for the control group were blocked from receiving IHM data.  After 6 months, all physicians received IHM information for patient care.  The primary end point of the study was a statistically significant reduction in treatment events, as defined by hospitalizations for HF, or emergency or urgent care center visits requiring intravenous therapy.  Patients whose physicians had access to IHM data had 22 % lower HF-related events; however this difference in the primary study end point was not statistically significant (p = 0.33).  However, in the NYHA class III subgroup, there was a statistically significant 41 % reduction in the event rate for those patients whose physicians were accessing IHM data.  The class IV (severe) subgroup did worse than the control group.  The event rate over the course of the 6 months was 0.70 for IHM-monitored patients whose physicians could see the data, compared to 0.89 for the control group.  Patients whose physicians had access to IHM data also had 21 % fewer hospitalizations.  The relative risk of HF hospitalizations was 0.79 in the group with access to IHM data compared to the blocked access group, a difference that was statistically significant.  A retrospective analysis of the time to first HF hospitalization showed a 36 % reduction (p = 0.03) in the relative risk of a HF-related hospitalization in the IHM group.  In addition, the group whose physicians had access to IHM data had a 46 % increase in the proportion of patients who improved over the 6 months and a 34 % reduction in the proportion who worsened, compared to 35 % and 51 % in the control group, respectively.  Primary safety related study end points were met, including freedom from system-related complications and freedom from pressure-sensor failure.  System-related complications occurred in 8 % of the 277 patients who underwent implantation, and all but 4 complications were successfully resolved.  There were no pressure-sensor failures after 6 months.

The Canadian Agency for Drugs and Technologies in Health's assessment on implantable hemodynamic monitoring (the Chronicle IHM System) (Ho, 2008) stated that preliminary evidence from observational studies suggested a potential for reducing hospitalizations with the use of right ventricle implantable hemodynamic monitoring (IHM).  The assessment noted, however, although a multi-center, randomized controlled trial (COMPASS-HF) showed a reduction in hospitalizations in the IHM group, the results were not statistically significant and the U.S. FDA panel concluded the trial failed to meet its primary efficacy end point.  The assessment noted that, in the COMPASS-HF study, the most common device-related complication was lead dislodgement.  The report stated that large randomized controlled trials are needed to demonstrate the clinical utility of IHM, particularly in terms of its impact on reducing hospitalization and improving patient outcomes.

CardioMEMS Implant

Abraham (2013) noted that HF represents a major public health concern, associated with high rates of morbidity and mortality.  A particular focus of contemporary HF management is reduction of hospital admission and re-admission rates.  While optimal medical therapy favorably impacts the natural history of the disease, devices such as cardiac resynchronization therapy devices and implantable cardioverter defibrillators have added incremental value in improving HF outcomes.  These devices also enable remote patient monitoring via device-based diagnostics.  Device-based measurement of physiological parameters, such as intra-thoracic impedance and HR variability, provide a means to assess risk of worsening HF and the possibility of future hospitalization.  Beyond this capability, implantable hemodynamic monitors have the potential to direct day-to-day management of HF patients to significantly reduce hospitalization rates.  The use of a pulmonary artery pressure measurement system has been shown to significantly reduce the risk of HF hospitalization in a large RCT, the CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients (CHAMPION) trial.  Observations from a pilot study also supported the potential use of a left atrial pressure monitoring system and physician-directed patient self-management paradigm; these observations are under further investigation in the ongoing LAPTOP-HF trial.  

The CardioMEMS HF System is an implantable device that is used to monitor heart rate and pulmonary artery (PA) pressure in certain individuals with HF. A small, paper clip-sized sensor is implanted into the pulmonary artery during a heart catheterization procedure. Once the device is implanted and the individual returns home, the Patient Electronics System uses wireless technology to read the PA pressure measurements and then transmits the information to the physician. Individuals may obtain a daily reading with the system and their physician can make medication adjustments based on the information received. The patient lies on a special pillow for a short time each day. The pillow gathers information from the pulmonary artery sensor and transmits the data directly to the heart failure team. The recipient of the device must be able to tolerate two types of anticoagulation medication for one month after the implantation procedure.

On May 28, 2014, the FDA cleared the CardioMEMS Heart Failure System for use in monitoring the heart rates and pulmonary arterial pressures of individuals with NYHA Class III heart failure who have been placed in the hospital for heart failure within the previous 12 months (FDA, 2014). 

The Champion heart failure sensor is a capsule-sized (15 mm by 3 mm) wireless microelectromechanical (MEMS) device that is permanently implanted into the pulmonary artery to monitor pulmonary artery pressure (PAP) and cardiac output (Optum, 2014). The pressure-sensitive sensor consists of a coil and capacitor sealed in silicone. Two nitinol loops anchor the hemodynamic sensor into place within the pulmonary artery branch. The battery-free sensor is powered by external radiofrequency energy from an external antenna wand. Pressure changes cause shifts in the sensor’s resonant frequency, which is picked up by the antenna. The patient uses the wand to take daily 20-second readings from the Champion implant, and the antenna transmits the gathered data to a secure Web site for access by health care providers who can tailor the patient’s medication according to the readings. The Champion device is delivered through the femoral vein using a preloaded Swan-Ganz catheter-based system that advances the device into the pulmonary artery. After the procedure, which takes place in a catheterization lab, patients remain in the hospital overnight for observation. Anticoagulant therapy is given for 1 month after device implantation, followed by daily aspirin therapy.

Abraham et al (2011) reported on the CHAMPION trial, a single-blind trial that found a reduced rate of hospital admission with the CardioMEMS implantable hemodynamic monitoring system.  Patients with NYHA class III heart failure, irrespective of the left ventricular ejection fraction, and a previous hospital admission for heart failure were enrolled in 64 centers in the United States.  They were randomly assigned by use of a centralized electronic system to management with a wireless implantable hemodynamic monitoring (W-IHM) system (treatment group) or to a control group for at least 6 months.  Only patients were masked to their assignment group.  In the treatment group, clinicians used daily measurement of pulmonary artery pressures in addition to standard of care versus standard of care alone in the control group.  The primary efficacy end-point was the rate of heart-failure-related hospitalizations at 6 months.  The safety end-points assessed at 6 months were freedom from device-related or system-related complications (DSRC) and freedom from pressure-sensor failures.  All analyses were by intention to treat.  In 6 months, 83 heart-failure-related hospitalizations were reported in the treatment group (n = 270) compared with 120 in the control group (n = 280; rate 0.31 versus 0.44, hazard ratio [HR] 0.70, 95 % CI: 0.60 to 0.84, p < 0·0001).  During the entire follow-up (mean 15 months [SD 7]), the treatment group had a 39 % reduction in heart-failure-related hospitalization compared with the control group (153 versus 253, HR 0.64, 95 % CI: 0.55 to 0.75; p < 0.0001).  Eight patients had DSRC and overall freedom from DSRC was 98.6 % (97.3 to 99.4) compared with a pre-specified performance criterion of 80 % (p < 0.0001); and overall freedom from pressure-sensor failures was 100 % (99.3 to 100.0). 

Commenting on this study, an accompanying editorialist (Krum, 2011) observed that there was a clear risk of overly aggressive diuresis or vasodilation to bring down raised pulmonary artery pressures in the intervention group in which these pressures were known. However, few data were provided on adverse events specifically related to drug changes, such as dizziness or postural hypotension. Furthermore, no information was given about what drugs were changed in this trial, which the editorialist said was surprising because these treatment changes are the presumed reason for the achieved differences in clinical outcomes between the groups. The editorialist stated that we will have to await future reports to determine exactly how the reductions in hospital admission for heart failure were achieved in CHAMPION. The editorialist also noted that, although patients generally received best-practice background therapy (as reflected by low event rates in the control group), it was not clear whether any (or how many) were also receiving adjustments to their therapy guided by measurement of B-type natriuretic peptide, which would provide useful and complementary information for ongoing management.

Abraham and colleagues (2014) stated that implantable monitoring devices have been developed to detect early evidence of HF decompensation, with the hypothesis that early detection might enable clinicians to commence therapy sooner than would otherwise be possible, and potentially to reduce the rate of hospitalization.  In addition to the usual challenges inherent to device trials (such as the difficulty of double-blinding and potential for bias), studies of implantable monitoring devices present unique difficulties because they involve assessment of therapeutic end-points for diagnostic devices.  Problems include the lack of uniform approaches to treatment in study protocols for device alerts or out-of-range values, and the requirement of levels of evidence traditionally associated with therapeutic devices to establish safety and effectiveness.  In this review, the approaches used to deal with these issues are discussed, including the use of objective primary end-points with blinded adjudication, identical duration of follow-up and number of encounters for patients in active monitoring and control groups, and treatment recommendations between groups that are consistent with international guidelines.  The authors concluded that remote monitoring devices hold promise for reducing the rate of hospitalization among patients with HF.  However, optimization of regulatory approaches and clinical trial design is needed to facilitate further evaluation of the effectiveness of combining health information technology and medical devices.

Benza and associates (2015) conducted a retrospective analysis of the CHAMPION trial of an implantable hemodynamic monitor (IHM) in 550 NYHA Functional Class III HF patients, regardless of LVEF or HF etiology.  These investigators evaluated clinical variables, changes in medical therapy, HF hospitalization rates and survival in patients with and without WHO Group II pulmonary hypertension (PH).  Data were obtained for 314 patients (59 %) who had WHO Group II PH.  Patients without PH were at significantly lower risk for mortality than PH patients (hazard ratio [HR] 0.31, 95 % CI: 0.19 to 0.52, p < 0.0001).  Pulmonary hypertension patients had higher HF hospitalization rates than non-PH patients (0.77/year versus 0.37/year; HR 0.49, 95 % CI: 0.39 to 0.61, p < 0.001).  In patients with and without PH, ongoing knowledge of hemodynamic data resulted in a reduction in HF hospitalization for PH patients (HR 0.64, 95 % CI: 0.51 to 0.81, p = 0.002) and for non-PH patients (HR 0.60, 95 % CI: 0.41 to 0.89, p = 0.01).  Among PH patients, there was a reduction in the composite end-point of death and HF hospitalization with ongoing knowledge of hemodynamics (HR 0.74, 95 % CI: 0.55 to 0.99, p = 0.04), but no difference in survival (HR 0.78, 95 % CI: 0.50 to 1.22, p = 0.28).  The authors concluded that WHO Group II PH is prevalent and identified HF patients at risk for adverse outcomes.  Ongoing knowledge of hemodynamic variables may allow for more effective treatment strategies to reduce the morbidity of this disease.

The California Technology Assessment Forum (CTAF) (Ollendorf et al, 2015) completed a clinical comparative effectiveness review of the CardioMEMS HF System for CHF.  The review concluded that the current body of evidence was promising but inconclusive: "For patients with Class III CHF with either reduced or preserved ejection fraction who have been hospitalized in the prior 12 months, we judge there to be moderate certainty of a small net benefit for the CardioMEMS HF System compared with usual monitoring of patients’ signs and symptoms.  There is moderate certainty because while the CHAMPION trial indicated that patients had fewer hospitalizations when care was informed by the CardioMEMS HF System, the results of the CHAMPION study are limited by concerns regarding the potential confounding influence of the study nurse on the superior outcomes in the treatment arm.  In addition, while post-hoc analyses have been presented illustrating reductions in cardiovascular mortality with CardioMEMS, there have been no published data from trials powered to detect mortality differences.  It seems reasonable to surmise that ongoing post-marketing trials evaluating the device may demonstrate a wide variety of outcomes, from substantial net health benefit to a small likelihood of overall 'negative' benefit given the potential harms associated with device placement.  Therefore, we judge the current body of evidence on CardioMEMS to be 'promising but inconclusive' using the ICER Evidence Rating framework".

Sandhu and associates (2016) evaluated the cost-effectiveness of the CardioMEMS device in patients with CHF. These researchers developed a Markov model to determine the hospitalization, survival, quality of life, cost, and incremental cost-effectiveness ratio of CardioMEMS implantation compared with usual care among a CHAMPION trial cohort of patients with HF.  They obtained event rates and utilities from published trial data; and used costs from literature estimates and Medicare reimbursement data.  These investigators performed subgroup analyses of preserved and reduced EF and an exploratory analysis in a lower-risk cohort on the basis of the CHARM (Candesartan in Heart failure: Reduction in Mortality and Morbidity) trials.  CardioMEMS reduced lifetime hospitalizations (2.18 versus 3.12), increased QALYs (2.74 versus 2.46), and increased costs ($176,648 versus $156,569), thus yielding a cost of $71,462 per QALY gained and $48,054 per life-year gained.  The cost per QALY gained was $82,301 in patients with reduced EF and $47,768 in those with preserved EF.  In the lower-risk CHARM cohort, the device would need to reduce hospitalizations for HF by 41 % to cost less than $100,000 per QALY gained.  The cost-effectiveness was most sensitive to the device's durability.  The authors concluded that in populations similar to that of the CHAMPION trial, the CardioMEMS device is cost-effective if the trial effectiveness is sustained over long periods.; they stated that post-marketing surveillance data on durability will further clarify its value.

Vanoli and colleagues (2016) noted that HF is a pandemic condition that is challenging cardiology today. Remote monitoring of physiological data, obtained through self-reporting via telephone calls or, automatically, using external devices is a potential novel approach to implement management of patients with HF and reduce hospitalization rates.  Relatively large but, sometimes, contradicting information exists about the effectiveness of remote monitoring via different non-invasive approaches to reduce the economic and social burden of HF management.  This leaves still partly unaddressed this critical issue and generates the need for new approaches.  The CardioMEMS device that can chronically monitor pulmonary pressures from a small microchip inserted transvenously in the pulmonary artery appears to represent an innovative tool to challenge hospitalization rates.  Consecutive analyses from the CHAMPION study had indeed documented the effectiveness of the CardioMEMS in the remote monitoring of the pulmonary circulation status of patients with HF and in providing adequate information to optimally manage such patients with the final result of a significant hospitalization rate reduction.  The authors concluded that overall the reports from the CHAMPION study encouraged the use of CardioMEMS; but larger populations are needed to definitively prove its value.

Wang and Frishman (2017) noted that HF affects over 5.8 million patients in the United States, and can be very costly due to the number of hospitalizations and re-hospitalizations during the final years of life.  Due to the large number of hospitalizations for HF exacerbations, effective methods for preventing these occurrences are necessary.  Improvements in the outpatient treatment of HF, aided by non-invasive and invasive home monitoring methods, can reduce the number of hospitalizations.  Pulmonary pressure monitoring through the CardioMEMS system provides one method of hemodynamic assessment of patients.  The effectiveness of the CardioMEMS system in reducing the number of HF exacerbations has been explored in the CHAMPION trial (CardioMEMS Heart Sensor Allows Monitoring of Pressures to Improve Outcomes in NYHA Functional Class III Heart Failure Patients), which demonstrated a reduction in hospitalizations for HF exacerbations in patients whose medical management was guided by adjusting medications based on pulmonary pressures compared with clinical signs and symptoms.  Retrospective analyses suggested that HF patients of certain subgroups, including those with left heart dysfunction and those with preserved LVEF, could benefit from pulmonary pressure monitoring in controlling their HF.  The authors concluded that larger studies are needed to examine if mortality can be reduced with pulmonary pressure monitoring.

An UpToDate review on “Strategies to reduce hospitalizations in patients with heart failure” (Horwitz and Krumholz, 2017) states that “Implantable hemodynamic monitoring is of uncertain efficacy and thus not recommended.  The wireless CardioMEMS pulmonary artery monitoring device has been approved by the United States Food and Drug Administration to monitor pulmonary artery pressure and heart rate in patients with NYHA class III HF who have been hospitalized during the previous year.  Further study is needed to determine the efficacy and safety of this device … the efficacy of the CardioMEMS device is uncertain given concerns raised about potential bias introduced in the conduct of the CHAMPION trial (including interaction between the trial sponsor and clinical investigators on certain treatment group subjects) and the analysis of data”.

Furthermore, an UpToDate review on “Treatment and prognosis of heart failure with preserved ejection fraction” (Borlaug and Colucci, 2017) states that “The wireless CardioMEMS pulmonary artery monitoring device is approved by the United States Food and Drug Administration to monitor pulmonary artery pressure and heart rate in patients with NYHA class III HF who have been hospitalized during the previous year.  Further study is needed to determine the efficacy and safety of this device.  The CHAMPION randomized, single-blind trial found that transmission of pulmonary artery pressure data from the device reduced HF-related hospitalizations at six months (31 versus 44 %, HR 0.70, 95 % CI 0.60 to 0.84).  There was a 1.5 % rate of device- or system-related complications.  An exploratory subgroup analysis found that device-guided management reduced HF-related hospitalization in patients with preserved LVEF (≥ 40 % or ≥ 50 %), as well as in patients with LVEF < 40 %.  However, the efficacy of the CardioMEMS device in this population has not been established”.

Pike et al (2016) stated that in Norway the prevalence of chronic heart failure (HF) has been estimated to be 2 %, meaning 80,000 to 100,000 people.  Around 75 % of HF patients are older than 75 years old.  Also, patients diagnosed with HF account for approximately 5 % of all hospital admissions in Norway, and at any one time about 20 %of patients on a medicine department consist of HF patients.  The New York Heart Association (NYHA) has categorized HF into 4 classes.  Class I and class II are considered mild; Class III is considered moderate and class IV is considered severe.  The CardioMEMS HF System implantable pulmonary artery pressure sensor is to be used by patients classified within class III, i.e., moderate HF.  The CardioMEMS HF System is only commercially available in the USA.  In USA the CardioMEMS HF System was approved through the Premarket Approval (PMA) process by the U.S. Food and Drug Association (FDA) in May 2014.  Approval was based upon one randomized, controlled clinical trial.  The approved indication is: "This device is indicated for wirelessly measuring and monitoring pulmonary artery (PA) pressure and heart rate in NYHA Class III HF patients who have been hospitalized for HF in the previous year.  The hemodynamic data are used by physicians for HF management and with the goal of reducing HF hospitalizations".  This single technology assessment was commissioned by the National System for Managed Introduction of New Health Technologies within the Specialist Health Service in Norway.  They wanted Norwegian Institute of Public Health to evaluate the safety, efficacy, and health economic documentation for continuous monitoring of pulmonary artery pressure via an implanted lead-less and battery-less pressure sensor (CardioMEMS HF System) compared to standard treatment for the management of patients with NYHA class III HF.  The authors evaluated the submitted documentation up towards available published documentation.  They stated that the evidence on efficacy and safety had relative short follow-up periods, 18 and 31 months, respectively.  Furthermore, they stated that all the available evidence came from only 1 trial with few events; thus, the evidence may change with further studies available.

Heywood et al (2017) stated that elevated pulmonary artery (PA) pressures in patients with HF are associated with a high risk for hospitalization and mortality.  Recent clinical trial evidence demonstrated a direct relationship between lowering remotely monitored PA pressures and HF hospitalization risk reduction with a novel implantable PA pressure monitoring system (CardioMEMS HF System, St. Jude Medical).  This study examined PA pressure changes in the first 2,000 US patients implanted in general practice use.  De-identified data from the remote monitoring Merlin.net (St. Jude Medical) database were used to examine PA pressure trends from the first consecutive 2,000 patients with at least 6 months of follow-up.  Changes in PA pressures were evaluated with an area under the curve (AUC) methodology to estimate the total sum increase or decrease in pressures (mm Hg-day) during the follow-up period relative to the baseline pressure.  As a reference, the PA pressure trends were compared with the historic CHAMPION clinical trial (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Functional Class III Heart Failure Patients).  The area under the curve (AUC) results were presented as mean ± 2 SE, and “p” values comparing the AUC of the general-use cohort with outcomes in the CHAMPION trial were computed by the t-test with equal variance.  Patients were on average 70 ± 12 years old; 60 % were men; 34 % had preserved ejection fraction; and patients were followed-up for an average of 333 ± 125 days.  At implantation, the mean PA pressure for the general-use patients was 34.9 ± 10.2 mm Hg compared with 31.3 ± 10.9 mm Hg for CHAMPION treatment and 32.0 ± 10.5 mm Hg for CHAMPION control groups.  The general-use patients had an AUC of -32.8 mm Hg-day at the 1-month time mark, -156.2 mm Hg-day at the 3-month time mark, and -434.0 mm Hg-day after 6 months of hemodynamic guided care, which was significantly lower than the treatment group in the CHAMPION trial.  Patients consistently transmitted pressure information with a median of 1.27 days between transmissions after 6 months.  The authors concluded that the first 2000 general-use patients managed with hemodynamic-guided HF care had higher PA pressures at baseline and experienced greater reduction in PA pressure over time compared with the pivotal CHAMPION clinical trial.  These data demonstrated that general use of implantable hemodynamic technology in a non-trial setting led to significant lowering of PA pressures.  They stated that further observational studies linked to available Medicare outcomes databases may provide more insight into the impact on healthcare use.

This study had several drawbacks.  The database used to acquire data in this study was de-identified, and some of the available demographic information was voluntarily entered by the user.  As a result, no information about healthcare use, medication changes, quality of life, or other important outcomes was available.  The benefit of large numbers of patients to describe the impact on pressure information and patient behavior outweighed, but did not replace, the desire for specific clinical outcomes evaluation.  Although individual patient-level clinical information was not available in this large observational data set, these researchers assumed that practitioners implanted only the indicated patients.

Desai et al (2017) noted that in the CHAMPION trial, HF hospitalization (HFH) rates were lower in patients managed with guidance from an implantable pulmonary artery pressure (PAP) sensor compared to usual care.  These investigators examined the effectiveness of ambulatory hemodynamic monitoring in reducing HFH outside the clinical trial setting.  They conducted a retrospective cohort study using US Medicare claims data from patients undergoing PAP sensor implantation between 6/1/2014 and 12/31/2015.  Rates of HFH during pre-defined periods before and after implantation were compared using the Andersen-Gill extension to the Cox proportional hazards model while accounting for the competing risk of death, ventricular assist device (VAD), or cardiac transplantation.  Comprehensive HF-related costs were compared over the same periods.  Among 1,114 implanted patients, there were 1,020 HFH in the 6 months before, compared with 381 HFH, 139 deaths, and 17 VAD/transplants in the 6 months after implantation (hazard ratio [HR] 0.55, 95 % confidence interval [CI]: 0.49 to 0.61, p < 0.001).  This lower rate of HFH was associated with a 6-month comprehensive HF cost reduction of $7,433 per patient (95 % CI: $7,000 to 7,884) and was robust in analyses restricted to 6-month survivors.  Similar reductions in HFH and costs were noted in the subset of 480 patients with complete data available for 12 months before and after implantation (HR 0.66, 95 % CI: 0.57 to 0.76, p < 0.001).  The authors concluded that as in clinical trials, use of ambulatory hemodynamic monitoring in clinical practice reduced HFH and comprehensive HF costs.  These benefits were sustained to 1 year and supported the “real world” effectiveness of this approach to HF management.

This study had several drawbacks.  First, these analyses were derived from Medicare claims data, and accordingly these researchers were unable to provide details regarding medical history, ejection fraction, the indication for PAP sensor implantation, quality of life, device safety, and the like.  An objective method of identifying HF hospitalizations per CMS methodology was used for this claims data-set, and there was no formal clinical event adjudication.  Only Medicare charges were incorporated in the cost analyses, and accordingly, these investigators were unable to account for the personnel costs associated with remote management.  Since this was a cohort-based comparison of outcomes before and after device implantation, not a prospective randomized study, the authors could not exclude the possibility that selection bias or enhancements of HF disease management in the period after device implant may also have confounded these findings.  However, since all patients had previously been hospitalized for HF and since all implanting centers were selected for their experience of HF management, it was likely that background medical therapy did not differ markedly in the periods before and after implantation.  As well, since HF is a progressive disease, with rates of hospitalization accelerating with progression towards the end-stage, these results likely reflect a conservative estimate of the reductions in worsening HF, health care utilization, and cost that were likely to be seen with ambulatory hemodynamic monitoring in practice.  Although censoring at the time of death, VAD, and transplant introduced the potential for survivor bias, consistent reductions in HFH in models accounting for competing risks as well as sensitivity analyses restricted to patients at risk for the full duration of follow-up (6 or 12 months) suggesting that this bias did not meaningfully influence the results.

Givertz and colleagues (2017) noted that despite increased use of guideline-directed medical therapy (GDMT), some patients with HF and reduced EF (HFrEF) remain at high risk for hospitalization and mortality.  Remote monitoring of PAP provides clinicians with actionable information to help further optimize medications and improve outcomes.  CHAMPION (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients trial) analyzed PA pressure-guided HF management in patients with HFrEF based on their ability to tolerate GDMT.  CHAMPION enrolled 550 patients with chronic HF regardless of LVEF.  A pre-specified sub-group analysis compared HF hospitalization and mortality rates between treatment and control groups in HFrEF patients (LVEF less than or equal to 40 %).  Post-hoc analyses in patients who tolerated GDMT were also performed.  Hospitalizations and mortality were assessed using Andersen-Gill and Cox proportional hazards models.  In 456 patients with HFrEF, HF hospitalization rates were 28 % lower in the treatment group than in the control group (HR: 0.72; 95 % CI: 0.59 to 0.88; p = 0.0013), with a strong trend for 32 % lower mortality (HR: 0.68; 95 % CI: 0.45 to 1.02; p = 0.06).  A 445-patient subset received at least 1 GDMT (angiotensin-converting enzyme inhibitor/angiotensin receptor blocker, or beta-blocker) at baseline; these patients had 33 % lower HF hospitalization rates (HR: 0.67; 95 % CI: 0.54 to 0.82; p = 0.0002) and 47 % lower mortality (HR: 0.63; 95 % CI: 0.41 to 0.96, p = 0.0293) than controls.  Compared with controls, patients receiving both components of optimal GDMT (n = 337) had 43 % lower HF hospitalizations (HR: 0.57; 95 % CI: 0.45 to 0.74; p < 0.0001) and 57 % lower mortality (HR: 0.43; 95 % CI: 0.24 to 0.76; p = 0.0026).  The authors concluded that PAP-guided HF management reduced morbidity and mortality in patients with HFrEF on GDMT, underscoring the important synergy of addressing hemodynamic and neurohormonal targets of HF therapy.  Moreover, they stated that additional post-market investigations are underway to definitively validate this new synergistic therapeutic strategy, which integrates target-dose neurohormonal control coupled with dynamic modulation of ambulatory PAP.

The main drawback of this study was that although the CHAMPION trial prospectively planned to evaluate clinical outcomes by baseline ejection fraction, the current analysis of the ability of patients with HFrEF to tolerate neurohormonal antagonist therapies was not explicitly prospectively planned.  Thus, these findings should be viewed as hypothesis-generating and supportive of the concept concerning the impact of adequate PAP treatment on mortality rates.

The Swedish Office of Technology Assessment report on “Measurement of pulmonary artery pressure in heart failure with implantable sensor” (Blomstrom-Lundqvist et al, 2018) stated that “The reported clinical effect of CardioMEMS and the Norwegian report is based on only a moderately large randomized, good quality study, but demonstrates statistically convincing and consistent outcomes of clinical relevance, including improvement in quality of life.  There is also a good theoretical basis for why measurement of pulmonary artery pressure may be important in the treatment of heart failure patients.  However, the results of the CardioMEMS study are based on a control group that does not fully correspond to modern heart disease.  For example, no measurements of natriuretic peptides (BNP or NT-proBNP) were used to assess possible impairment of heart failure.  New drugs containing sacubitrile/valsartan, which provided improved survival and other clinical routines, such as intensive, regular clinical control, may mean that the additional benefit of CardioMEMS in clinical practice is less than in the current study.  The study lacks a description of the patient population for the left ventricle ejection fraction (EC) and a more accurate classification of the type of heart failure in the studied population.  Although it is a multi-center study, consistency of results between different regions/countries has not been reported.  Furthermore, the follow-up period is relatively short.  In order to highlight the risk of treatment and instrument-related complications in the long term, data from ongoing long-term studies of safety are required.  Data from these are expected to be published in 2019 and 2020.  Due to the weaknesses described above, it would be of great value with a confirmatory randomized study of CardioMEMS in a context that corresponds to modern cardiovascular care where comparisons are made with heart failure treatment controlled by sampling with natriuretic peptide.  Such a study should also aim at identifying patient groups that can primarily benefit from monitoring pulmonary artery pressure even when using newer anti-heart failure drugs.  Such a study could be advantageously implemented as a wide-ranging, randomized, clinical trial study.  Taking into account principles for prioritizing interventions in healthcare and moderately severe heart failure is a serious condition, CardioMEMS can be a cost-effective method.  However, the transferability of the health-economic analysis to Swedish conditions is limited by the fact that the additional benefit of CardioMEMS may be over-estimated.  As the patient group is relatively large, an introduction could also have a significant impact on the budget and possible displacement effects for other urgent care and treatment for this group as well as patients with mild heart failure.  In its report from 2015, the National Board of Health also points to significant improvement in the relatively low rate of heart failure treatment.  As the use of CardioMEMS requires access to specialist expertise for submission, there is also a risk of displacement of other invasive actions that require the same specialist resource”.

Bradley and associates (2019) examined feasibility and mid-term outcomes of IHM use in the single ventricle/Fontan population.  A total of 6 adult Fontan patients (greater than 1 HF admission, NYHA functional class of greater than 3) were enrolled (30 ± 7 years old, mean PAP [mPAP] of 16 ± 4.7 mm Hg).  Heart failure mediated events (HFME) were evaluated for 12 months: CV medication change, hospital admission, paracentesis, and change in orthotopic heart transplant (OHT) listing status.  The IHM device was successfully placed in all subjects.  In total there were 671 IHM transmissions and 25 (3.7 %) HFME.  The mPAP across all episodes was 18.2 ± 6.6 mm Hg (range of 6 to 40 mm Hg).  Higher mPAP were associated with greater odds of having a HFME (odds ratio [OR] 1.17 [1.09, 1.25], p < 0.0001), mPAP had good ability to discriminate transmissions associated with HFME (AUC 0.76 [0.654, 0.866]), with mean PA pressures of greater than 24 mm Hg or individual mPAP change of greater than 4 mm Hg, best discriminating transmissions associated with HFME.   The authors concluded that in the first feasibility series of adult Fontan patients undergoing CardioMEMS implantation, results demonstrated early technical success and no device-related adverse events (AEs).  These researchers proposed that ambulatory mPAP of greater than 24 mm Hg or individual mPAP change  of greater than 4 mm Hg may be associated with more HFME.  Moreover, these researchers stated that further large-scale studies in this population are recommended.

Biederman and colleagues (2019) examined the safety and feasibility of measuring volumetric and pressure parameters non-invasively using simultaneous cardiovascular magnetic resonance (cMR) volumetric data and time-resolved pressure waveforms from previously implanted CardioMEMS devices in pulmonary arterial hypertension (PAH) patients.  Opportunities to intervene during clinically occult phases in PAH promise to herald a key transformation in current practice for treating this complex population.  Currently, it is possible and convenient to monitor daily PAP in PAH patients using the CardioMEMS device to determine clinically silent progression.  Supplementation of these pressures with other prognostic measurements of right ventricular (RV) contractility, PA resistance and RV/PA coupling could add further predictive capabilities.  In this study, PAH patients (n = 17) with NYHA functional class III or IV HF and recent HF related hospitalizations were implanted with the CardioMEMS device as part of a NHLBI sponsored Trial.  Implanted patients were then assessed using cMR imaging of the RV along with measurement of PA flow.  Patients were imaged at 1-month post-implant (baseline) and at 4-month follow-up time (n = 12).  At baseline, patients were studied at rest and then under 3 different physiologic conditions: inhaled nitric oxide (INO), dobutamine (Dob) stress and volumetric stress (Vol), using a multiple slice short-axis imaging and a rapid imaging protocol.  All patients were safely imaged, with no artifacts obscuring the cMR images.  RV volumes were measured successfully at rest and under each stress condition using a reduced scan approach that required calibration for each patient, which achieved a correlation r2 of 0.98.  Variables measured included the maximal pulmonary artery elastance (Ea), maximal RV myocardial elastance (Emax) and ventricular-vascular coupling ratio (VVC).  The response to stressors was determined on a patient basis.  No complications occurred during the cMRI examination.  The authors concluded that it was safe and feasible to perform cMR imaging with simultaneous PAP readings from the CardioMEMS device.  A reduced scan approach was developed to allowed measurement of RV volumes during stress conditions.  Volumetric and pressure measurements could be combined to examine fundamental myocardial properties (e.g., Emax, Ea and VVC) in PAH patients serially over time.  These researchers stated that in the future, these parameters could be tested as serial predictors of outcome and response to therapies in PAH.

The authors stated that this study had several drawbacks.  The methods and results presented were limited to demonstrating the feasibility of combining cMR and CardioMEMS during stress conditions.  To the authors’ knowledge, they were the only center to routinely perform simultaneous cMR and CardioMEMS interrogations, and the general approach may find greater use in clinical research applications, in part, the goals of the ongoing NHLBI Trial.  This study was not designed to demonstrate the utility of provocative testing but to show that it could be performed safely in the cMR scanner.  The ‘”tress” testing was performed in a fashion to reasonably permit “return to baseline”, but demonstration of this was not always feasible given the overlap of recover from one stress and establishment of a second stress.

Benza and co-workers (2019) examined the safety and feasibility of monitoring patients with PAH and right-sided HF using the CardioMEMS HF System.  The CardioMEMS HF sensors were implanted in 26 patients with PAH with NYHA functional class III or IV right-sided HF (51.3 ± 18.3 years of age, 92 % women, 81 % NYHA class III).  PAH therapy was tracked using a minimum of weekly reviews of CardioMEMS HF daily hemodynamic measurements.  Safety, functional response, and hemodynamic response were tracked up to 4 years with in-clinic follow-ups.  The CardioMEMS HF System was safely used to monitor PAH therapy, with no device-related serious adverse events observed and a single preimplant serious AE.  Significant PAP reduction and cardiac output elevation were observed as early as 1 month post-implant using trends of CardioMEMS HF data, coupled with significant NYHA functional class and quality of life (QOL) improvements within 1 year.  The authors concluded that the CardioMEMS HF System provided useful information to monitor PAH therapy, and demonstrated short- and long-term safety.  Moreover, these researchers stated that larger clinical trials are needed before its widespread use to guide therapy in patients with severe PAH with right-sided HF.

Salavitabar and colleagues (2020) stated that ambulatory PA pressure monitoring with IHMs has been shown to reduce HF-related hospital admissions in non-congenital heart disease (CHD) populations.  HF is a common late cardiovascular complication in adult CHD necessitating better understanding of IHM application in this population.  These researchers described the technical considerations of transcatheter implantation of the CardioMEMS HF System in adult patients with complex palliated CHD and advanced HF.  They analyzed adults with complex CHD and advanced HF who were referred for CardioMEMS device implantation (2015 to 2018).  Feasibility of device implantation, defined by successful device implantation and calibration, and procedural outcomes were evaluated.  CardioMEMS was successfully implanted in all 14 adults (age of 35.5 ± 9.2 years, weight of 72 ± 12 kg) with complex CHD (single ventricle/Fontan, n = 8 [57 %]; d-transposition of the great arteries/atrial switch, n = 6 [43 %]).  The device was delivered via femoral venous access in 13 (93 %) patients and implanted in the left PA in 12 (86 %).  A long sheath was used in 8 (57 %) patients, including 5/6 with an atrial switch operation.  There was 1 device migration that did not require retrieval.  The authors concluded that transcatheter implantation of an IHM was feasible in select complex adult CHD patients with advanced HF.  Moreover, these researchers stated that further studies examining integration of ambulatory hemodynamics and the impact on clinical care are needed.  They noted that this technology has the potential to improve medical management of advanced HF in patients with Fontan and atrial switch physiologies and provide new insights into their ambulatory hemodynamics.

Shavelle and associates (2020) noted that ambulatory hemodynamic monitoring with an implantable pulmonary artery (PA) sensor is approved for patients with NYHA Class III (HF and a prior HF hospitalization (HFH) within 12 months.  In a prospective, observational, multi-center, open-label, single-arm study, these researchers examined the safety and efficacy of PA pressure-guided therapy in routine clinical practice with special focus on subgroups defined by sex, race, and ejection fraction.  This trial included 1,200 patients across 104 centers within the United States with NYHA class III HF and a prior HFH within 12 months evaluated patients undergoing PA pressure sensor implantation between September 1, 2014, and October 11, 2017.  The primary efficacy outcome was the difference between rates of adjudicated HFH 1 year after compared with the 1 year before sensor implantation.  Safety end-points were freedom from device- or system-related complications at 2 years and freedom from pressure sensor failure at 2 years.  Mean age for the population was 69 years, 37.7 % were women, 17.2 % were non-White, and 46.8 % had preserved ejection fraction.  During the year after sensor implantation, the mean rate of daily pressure transmission was 76 ± 24 % and PA pressures declined significantly.  The rate of HFH was significantly lower at 1 year compared with the year before implantation (0.54 versus 1.25 events/patient-years, hazard ratio 0.43 [95 % CI: 0.39 to 0.47], p < 0.0001).  The rate of all-cause hospitalization was also lower following sensor implantation (1.67 versus 2.28 events/patient-years, hazard ratio 0.73 [95 % CI: 0.68 to 0.78], p < 0.0001).  Results were consistent across subgroups defined by ejection fraction, sex, race, cause of cardiomyopathy, presence/absence of implantable cardiac defibrillator or cardiac re-synchronization therapy and ejection fraction.  Freedom from device- or system-related complications was 99.6 %, and freedom from pressure sensor failure was 99.9 % at 1 year.  The authors concluded that in routine clinical practice as in clinical trials, PA pressure-guided therapy for HF was associated with lower PA pressures, lower rates of HFH and all-cause hospitalization, and low rates of adverse events (AEs) across a broad range of patients with symptomatic HF and prior HFH.  It should be noted that this was an industry-sponsored study.

The authors stated that this study had several drawbacks.  By design, this Post-Approval Study was a single-arm study comparing patients before and after enrollment with no randomized control group.  There was likely under-estimation of HFH events before enrollment due to incomplete recall of events (information bias).  This factor would have decreased the ability to detect benefit from the intervention, after which all events were prospectively reported.  Censoring at the time of death may have resulted in survivor bias; however, patients who died did contribute 89 patient-years to the follow-up after device implant.  The CardioMEMS Post-Approval Study enrolled high-risk patients with mortality comparable to that observed in the contemporary HF trials.  The pre-implant risk of HFH in the CardioMEMS Post-Approval Study was approximately 2-fold higher than those enrolled in the open-access study after the randomized period of the CHAMPION trial.  Despite the higher baseline risk in the CardioMEMS Post-Approval Study population, these investigators found comparable reduction in hospitalizations between this study, CHAMPION, and the open-access studies.

Angermann and colleagues (2020) stated that HF leads to repeat hospitalizations and reduces the duration and quality of life (QOL).  Pulmonary artery pressure (PAP)-guided HF management using the CardioMEMS HF system was shown to be safe and reduce HFH rates in NYHA class III patients.  However, these findings have not been replicated in health systems outside the United States.  Thus, the CardioMEMS European Monitoring Study for Heart Failure (MEMS-HF) evaluated the safety, feasibility, and performance of this device in Germany, the Netherlands, and Ireland.  A total of 234 NYHA class III patients (68 ± 11 years, 22 % women, greater than or equal to 1 HFH in the preceding year) from 31 centers were implanted with a CardioMEMS sensor and underwent PAP-guided HF management.  One-year rates (95 % CI] of freedom from device- / system-related complications and from sensor failure (co-primary outcomes) were 98.3 % (95.8 to 100.0) and 99.6% (97.6 to 100.0), respectively.  Survival rate was 86. 2%.  For the 12 months post- versus pre-implant, HFHs decreased by 62 % (0.60 versus 1.55 events/patient-year; hazard ratio 0.38 [95 % CI: 0.31 to 0.48], p < 0.0001).  After 12 months, mean PAP decreased by 5.1 ± 7.4 mmHg, Kansas City Cardiomyopathy Questionnaire [KCCQ] Overall/Clinical Summary Scores increased from 47.0 ± 24.0/51.2 ± 24.8 to 60.5 ± 24.3/62.4 ± 24.1 (p < 0.0001), and the 9-item Patient Health Questionnaire sum-score improved from 8.7 ± 5.9 to 6.3 ± 5.1 (p < 0.0001).  The authors concluded that the MEMS-HF study found that hemodynamic-guided HF management using an implanted PAP sensor is safe and feasible.  Furthermore, there was an association between hemodynamic-guided HF management and reductions in HFH.  MEMS-HF results support the generalizability of this management approach, provided the necessary infra-structural resources are available.  In addition, an association between the magnitude of PAP decreases and improvements in patient-reported outcomes was observed.  Together, these findings add to evidence from randomized trial results and support the concept that active medication changes intended to lower remotely-obtained PAP values have potential clinical benefit over remote clinical management alone and are feasible in HF out-patients with persistent NYHA III symptoms following HFH.  This approach might prove particularly valuable as virtual healthcare visits gain importance because it helps maintain effective out-patient management when personal contact is problematic.  It should be noted that this was an industry-sponsored study.

The authors stated that a number of potential limitations must be considered when interpreting the MEMS-HF findings.  Although helpful for evaluating safety and feasibility, prospective registries using historical events for within-patient comparisons cannot provide definitive effectiveness data.  The post-implant changes in HFH observed in MEMS-HF supported the concept that remote hemodynamic-guided HF management may be superior to clinical management strategies alone.  However, the observed effect sizes must be viewed with caution.  Several uncontrolled biases may have impacted the results, including information bias, regression to the mean, asymmetrical data handling, and confounding or selection of patients thought to be adherent to remote patient management requirements.

In an editorial that accompanied the afore-mentioned study by Angerman et al (2020), Srivastava and Heywood (2020) noted that “This well-conducted trial may increase acceptance in Europe and elsewhere, especially as QoL changes are extremely important to patients.  However, what is lacking is a second confirmatory larger trial supporting (or refuting) the results of CHAMPION, but also addressing the key unanswered question: Does haemodynamic monitoring improve survival?  Mortality is the touchstone of randomized trials in HF because this syndrome is lethal and widespread. Important therapies for HF have all shown reductions in mortality … The determination of diastolic PAP on a daily basis seems very promising … perhaps measurement of this number will make our daily management of HF less ‘meagre and unsatisfactory’, for both our patients and ourselves”.

The Austrian Institute for Health Technology Assessment (AIHTA)'s review of "Implantation of a wireless pulmonary artery pressure sensor in patients with advanced heart failure" (Winkler and Wild, 2020) states that "The current evidence suggests that the CardioMEMS HF System for Heart Failure Patients (NYHA III) is more effective than standard monitoring programs for both heart failure-related hospitalization and hospitalization for any cause.  In addition, while there were better quality of life scores in the intervention group, the clinical relevance of the group differences needs to be critically questioned.  Regarding serious adverse events, the included literature reported only a small number of complications.  However, the reported observation period was very short.  Finally, the results on the efficacy and safety of the implant have to be evaluated against the background of potential conflicts of interest (company sponsoring and funding of study authors".  Furthermore, the authors noted that a randomized controlled multi-center trial (involving 139 centers) of the CardioMEMS HF system is currently underway, involving 3,600 participants and is expected to be completed by mid-2023.

Furthermore, an UpToDate review on “Treatment and prognosis of heart failure with preserved ejection fraction” (Borlaug and Colucci, 2020) states that “The wireless CardioMEMS pulmonary artery monitoring device is approved by the United States Food and Drug Administration to monitor pulmonary artery pressure and heart rate in patients with NYHA class III HF who have been hospitalized during the previous year.  Further study is needed to determine the efficacy and safety of this device”.

Radhoe and associates (2021) stated that the large and growing burden of CHF on healthcare systems and economies is mainly caused by a high hospital admission rate for acute decompensated HF.  Several remote monitoring techniques have been developed for early detection of worsening disease, potentially limiting the number of hospitalizations.  In the past several years, the scope has been shifting towards the relatively novel invasive sensors capable of measuring intra-cardiac filling pressures, because it is believed that hemodynamic congestion precedes clinical congestion; thus, monitoring intra-cardiac pressures may enable clinicians to intervene and avert hospitalizations in a pre-symptomatic phase.  Several techniques were discussed in this review, and thus far, remote monitoring of PAP by the CardioMEMS HF System is the only technique with proven safety as well as efficacy with regard to the prevention of HF-related hospital admissions.  These investigators noted that currently, guideline recommendations for invasive monitoring are scarce.  In the 2016 European Society of Cardiology (ESC) Guidelines for the diagnosis and treatment of acute and chronic HF, CardioMEMS holds a class IIb recommendation for the monitoring of symptomatic HF patients with previous HF hospitalization.  No recommendations for invasive telemonitoring were provided in the latest US guidelines.  With the growing interest and body of evidence for invasive remote monitoring, it is expected that future guidelines will provide more recommendations.  CardioMEMS has by far been studied in the most detail and was shown to be cost-effective and safe; however, randomized clinical data is restricted to the U.S. setting.  A single observational European study showed positive results, but more evidence is needed for reimbursement in Western Europe.  The 1st European RCT is currently ongoing in the Netherlands and aims to demonstrate efficacy and cost-effectiveness of CardioMEMS PA monitoring in comparison to standard HF care.  The LAP sensors appeared promising and the VECTOR-HF trial will provide new insights regardless of results.  The authors concluded that pending new evidence, the CardioMEMS PA sensor appeared to be the most promising technique in the upcoming years with demonstrated safety and durability as well as efficacy in multiple international clinical and post-marketing studies.  It is expected that remote monitoring will play a larger role in HF care in the near future.

Joshi and Nair (2021) informed nurse practitioners and other healthcare professionals regarding the use of CardioMEMS in reducing HF-related hospital re-admission rates; and explained how CardioMEMS also may help to reduce the risk of Covid-19 in patients with HF.  The authors stated that CardioMEMS offers a promising method to monitor, manage, and decrease HF-related early and frequent re-admissions in HF patients.

In a pilot study, Veenis et al (2021) examined the safety and feasibility of using CardioMEMS monitoring in patients before and after left ventricular assist device (LVAD) surgery.  A total of 10 patients accepted for elective LVAD surgery were included, received a CardioMEMS at baseline and were categorized based on mean PAP (mPAP) of less than or equal to 25 mmHg (n = 4) or mPAP of greater than 25 mmHg (n = 6) before LVAD surgery.  The combined endpoint of all-cause mortality, acute kidney injury (AKI) and/or renal replacement therapy, and RV failure occurred more often in patients with an mPAP of greater than 25 mmHg (83 % versus 0 %, p = 0.017).  The authors concluded that the findings of this pilot study demonstrated that combining CardioMEMS monitoring with LVAD therapy was safe and generated the hypothesis that patients with an mPAP  of greater than 25 mmHg before LVAD surgery identify a very high-risk group for adverse clinical outcomes.

Airhart and colleagues (2021) noted that PAH is a chronic, progressive disease that is incurable, even with effective therapy.  Long-term outcome in PAH is best preserved by targeting hemodynamic improvements to reduce risk of subsequent RV failure.  Methods that can evaluate RV adaptation to stress have important implications to better understand an individual's physiology and may play a pivotal role in guiding therapy in PAH.  In a pilot study, these researchers examined the feasibility of monitoring hemodynamic response to 6-minute walk distance (6MWD) in patients with PAH using the CardioMEMS HF System.

Mazimba and co-workers (2021) stated that pulmonary artery proportional pulse pressure (PAPP) was recently shown to have prognostic value in HFrEF and pulmonary hypertension.  These researchers tested the hypothesis that PAPP would be predictive of adverse outcomes in patients with implantable PAP monitor (CardioMEMS).  Survival analysis with Cox proportional hazards regression was used to evaluate all-cause deaths and HFH in CHAMPION trial1 patients who received treatment with the CardioMEMS device based on the PAPP.  Among 550 randomized patients, 274 had PAPP of less than or equal to the median value of 0.583 while 276 had PAPP of greater than 0.583.  Patients with PAPP of less than or equal to 0.583 (versus PAPP of greater than 0.583) had an increased risk of HFH (HR 1.40, 95 % CI: 1.16 to 1.68, p = 0.0004) and experienced a significant 46 % reduction in annualized risk of death with CardioMEMS treatment (HR 0.54, 95 % CI: 0.31 to 0.92) during 2 to 3 years of follow-up.  This survival benefit was attributable to the treatment benefit in patients with HFrEF and PAPP of less than or equal to 0.583 (HR 0.50, 95 % CI: 0.28 to 0.90, p < 0.05).  Patients with PAPP of greater than 0.583 or HF with preserved EF (HFpEF) had no significant survival benefit with treatment (p > 0.05).  The authors concluded that lower PAPP in HFrEF patients with CardioMEMS constituted a higher mortality risk status.  Moreover, these researchers stated that more studies are needed to better understand clinical applications of PAPP in implantable PAP monitors.

Furthermore, an UpToDate review on “Investigational and emerging strategies for management of heart failure” (Colucci, 2021) states that “The wireless CardioMEMS pulmonary artery monitoring device has been approved by the US Food and Drug Administration to monitor pulmonary artery pressure and heart rate in patients with NYHA class III HF who have been hospitalized during the previous year.  Further study is needed to determine the efficacy and safety of this device.  The 2016 ESC HF guidelines included only a very weak recommendation stating that this device may be considered in symptomatic patients with HF with previous HF hospitalization”.

Assaad et al (2019) stated that hospital re-admission for congestive heart failure (CHF) remains one of the most important economic burdens on healthcare cost.  The implantation of a wireless pressure monitoring device (CardioMEMS) had led to nearly 40 % reduction in re-admission rates in the landmark CHAMPION trial.  In a retrospective, single-center, chart review, these researchers examined the effectiveness of this wireless device in reducing heart failure admissions in a real-world setting.  This trial included patients with recurrent admissions for heart failure, who were implanted with the wireless pressure monitoring system (CardioMEMS) at the authors’ institution.  These researchers studied the total number of all-cause hospital admissions as well as heart failure-related admissions pre- and post-implantation.  A total of 27 patients were followed for 6 to 18 months.  The total number of all-cause hospital admissions prior to device implantation was 61 admissions for all study patients, while the total number for the post-implantation period was 19, correlating with 2.26 + 1.06 admissions/person-year prior to device implantation versus 0.70 + 0.95 admissions/person-year post-implantation (p < 0.001).  For heart failure-related admissions, the total number prior to device implantation was 46 compared to 9 admissions post device implantations, correlating with 1.70 + 1.07 admissions/person-years pre-implantation versus 0.33 + 0.62 admissions/person-years post-implantation (p < 0.001).  This translated to 80.4 % and 68.9 % reduction in heart failure and all-cause admissions, respectively.  The authors concluded that in a real-world setting, the implantation of a wireless heart failure monitoring system in patients with heart failure and class III symptoms has resulted in 80.4 % reduction in heart failure admissions and 69 % reduction in all-cause admissions.  Moreover, these researchers stated that further, carefully designed and adequately powered studies are needed to confirm the suspected (and expected) secondary benefit in mortality.

The authors stated that this study had several drawbacks.  First, it included 27 patients, which was a relatively a small number of patients and might not reflect same outcomes at higher volume centers.  Second, study cohort was followed for 6 to 18 months, which was a relatively short duration of follow-up.  Third, 89 % of study cohort had heart failure with reduced ejection fraction (HFrEF), which might not represent the actual prevalence of heart failure subtypes among the general population.

Abraham et al (2019) noted that in a randomized clinical trial, heart failure (HF) hospitalizations were lower in patients managed with guidance from an implantable pulmonary artery pressure (PAP) sensor compared with usual care.  It remains unclear if ambulatory monitoring could also improve long-term clinical outcomes in real-world practice.  In a matched cohort study, these researchers examined the association between ambulatory hemodynamic monitoring and rates of HF hospitalization at 12 months in clinical practice.  Medicare beneficiaries used claims data collected between June 1, 2014, and March 31, 2016 were extracted for analysis.  Medicare patients who received implants of a PAP sensor were identified from the 100 % Medicare claims database.  Each patient who received an implant was matched to a control patient by demographic features, history of HF hospitalization, and number of all-cause hospitalizations.  Propensity scoring based on co-morbidities (arrhythmia, hypertension, diabetes, pulmonary disease, and renal disease) was used for additional matching.  Data analysis was completed from July 2017 through January 2019.  The rates of HF hospitalization were compared using the Andersen-Gill method.  Days lost owing to events were compared using a non-parametric bootstrap method.  The study cohort consisted of 1,087 patients who received an PAP sensor; and 1,087 matched control patients.  The treatment and control cohorts were well-matched by age (mean [SD], 72.7 [10.2] years versus 72.9 [10.1] years) and sex (381 of 1,087 female patients [35.1 %] in each group), medical history, co-morbidities, and timing of pre-implant HF hospitalization.  At 12 months post-implant, 616 HF hospitalizations occurred in the treatment cohort compared with 784 HF hospitalizations in the control cohort.  The rate of HF hospitalization was lower in the treatment cohort at 12 months post-implant (hazard ratio [HR], 0.76 [95 % confidence interval [CI]: 0.65 to 0.89]; p < 0.001).  The percentage of days lost to HF hospitalizations or death were lower in the treatment group (HR, 0.73 [95 % CI: 0.64 to 0.84]; p < 0.001) and the percentage of days lost owing to all-cause hospitalization or death were also lower (HR, 0.77 [95 % CI: 0.68 to 0.88]; p < 0.001).  The authors concluded that patients with HF who were implanted with a PAP sensor had lower rates of HF hospitalization than matched controls and spent more time alive out of hospital.  Ambulatory hemodynamic monitoring may improve outcomes in patients with chronic HF.  Moreover, these researchers stated that these findings are being prospectively evaluated in an ongoing randomized clinical trial (GUIDE-HF).

The authors stated that the drawbacks of this study were those inherent to an observational analysis using Medicare claims data.  Important clinical information, such as ejection fraction (EF), natriuretic peptide levels, and renal function, were not known.  Medical therapy, indications for PAP sensor implant, and complications of sensor implant were similarly not available.  Residual confounding by unmeasured co-variates remains possible.  These researchers were unable to evaluate medication changes or link outcomes to PAP sensor data; therefore, they could not definitely exclude the possibilities that selection bias or heightened involvement of the healthcare team after sensor implant, rather than interventions triggered by hemodynamic data per se, were partially responsible for differences in outcomes.  Finally, CMS methods were used to define the study endpoints, and clinical events were not formally adjudicated.  These investigators tried to reduce the inherent limitations of an observational, claims-based design by cohort matching based on demographic factors, co-morbidity profiles, and HF hospitalization frequency and timing.  While randomization remains the evidentiary gold standard for experimental design, the novel matching procedure allowed for a more rigorous outcomes comparison between cohorts.  Several pitfalls of using big data based on claims reporting are reduced using this method.

Shavelle et al (2020) stated that ambulatory hemodynamic monitoring with an implantable pulmonary artery (PA) sensor is approved for patients with New York Heart Association (NYHA) Class III heart failure (HF) and a prior HF hospitalization (HFH) within 12 months.  In a prospective, observational, open-label, single-arm, multi-center trial, these researchers examined the safety and efficacy of PA pressure-guided therapy in routine clinical practice with special focus on subgroups defined by sex, race, and ejection fraction (EF).  This trial enrolled 1,200 patients across 104 centers within the U.S. with NYHA class III HF and a prior HFH within 12 months evaluated patients undergoing PA pressure sensor implantation between September 1, 2014, and October 11, 2017.  The primary efficacy outcome was the difference between rates of adjudicated HFH 1 year after compared with the 1 year before sensor implantation.  Safety endpoints were freedom from device- or system-related complications at 2 years and freedom from pressure sensor failure at 2 years.  Mean age for the population was 69 years, 37.7 % were women, 17.2 % were non-White, and 46.8 % had preserved EF.  During the year after sensor implantation, the mean rate of daily pressure transmission was 76 ± 24 % and PA pressures declined significantly.  The rate of HFH was significantly lower at 1 year compared with the year before implantation (0.54 versus 1.25 events/patient-years, HR 0.43 [95 % CI: 0.39 to 0.47], p < 0.0001).  The rate of all-cause hospitalization was also lower following sensor implantation (1.67 versus 2.28 events/patient-years, HR 0.73 [95 % CI: 0.68 to 0.78], p < 0.0001).  Results were consistent across subgroups defined by EF, sex, race, cause of cardiomyopathy, presence/absence of implantable cardiac defibrillator or cardiac resynchronization therapy and EF.  Freedom from device- or system-related complications was 99.6 %, and freedom from pressure sensor failure was 99.9 % at 1 year.  The authors concluded that in routine clinical practice as in clinical trials, PA pressure-guided therapy for HF was associated with lower PA pressures, lower rates of HFH and all-cause hospitalization, and low rates of adverse events (AEs) across a broad range of patients with symptomatic HF and prior HFH.

The authors stated that this post-approval study had several drawbacks. By design, this trial was a single-arm study comparing patients before and after enrollment with no randomized control group.  There was likely under-estimation of HFH events before enrollment due to incomplete recall of events (information bias).  This factor would have decreased the ability to detect benefit from the intervention, after which all events were prospectively reported.  Censoring at the time of death may have resulted in survivor bias; however, patients who died did contribute 89 patient-years to the follow-up after device implant.  The CardioMEMS Post-Approval Study enrolled high-risk patients with mortality comparable to that observed in the contemporary HF trials.  The pre-implant risk of HFH in the CardioMEMS Post-Approval Study was approximately 2-fold higher than those enrolled in the open-access study after the randomized period of the CHAMPION trial.  Despite the higher baseline risk in the CardioMEMS Post-Approval Study population, these investigators found comparable reduction in hospitalizations between this study, CHAMPION, and the open-access studies.

Furthermore, an UpToDate review on “Investigational and emerging strategies for management of heart failure” (Colucci, 2022) lists “Implantable hemodynamic monitoring (CardioMEMS)” as one of the investigational therapies for chronic heart failure.  It states that “We suggest not using implantable hemodynamic monitoring as the efficacy of this approach is uncertain.  The wireless CardioMEMS pulmonary artery monitoring device has been approved by the US Food and Drug Administration to monitor pulmonary artery pressure and heart rate in patients with NYHA class III HF who have been hospitalized during the previous year.  Further study is needed to determine the efficacy and safety of this device.  The 2016 ESC HF guidelines included only a very weak recommendation stating that this device may be considered in symptomatic patients with HF with previous HF hospitalization.  The CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes In NYHA Class III Heart Failure Patients (CHAMPION) randomized single-blind trial of 550 patients found that transmission of pulmonary artery pressure data from the device reduced HF-related hospitalizations at 6 months (31 versus 44 %, HR 0.70, 95 % CI 0.60 to 0.84).  There was a 1.5 % rate of device- or system-related complications.  An exploratory subgroup analysis found that device-guided management reduced HF-related hospitalization in patients with preserved LVEF (LVEF ≥ 40 % or LVEF ≥ 50 %), as well as in patients with LVEF < 40 %.  Another exploratory analysis found that device-guided management reduced respiratory hospitalization rates as well as HF hospitalization rates in the entire cohort, as well as in a subgroup of 187 patients with chronic obstructive pulmonary disease”.

Hajduczok et al (2022) noted that in HF patients, remote monitoring using implantable devices may be used to predict and reduce HF exacerbations and mortality.  In a systematic review and meta-analysis, data from RCTs was examined to determine the effectiveness of implantable remote monitoring on the improvement of outcomes in HF patients.  Primary endpoints were all-cause mortality and a composite of cardiovascular (CV) and HF hospitalizations; rate ratios (RRs) and 95 % CI were calculated.  A secondary analysis tested for heterogeneity of treatment effect (HTE) comparing right ventricular/pulmonary pressure monitoring versus impedance-based monitoring on hospitalization. A regression analysis was performed using the mean follow-up time as the moderator on each primary endpoint.  A total of 11 RCTs (n = 6,196) were identified with a mean follow-up of 21.9 months.  The mean age and reported EF were 64.1 years and 27.7 %, respectively.  Remote monitoring did not reduce mortality (RR 0.89 [95 % CI: 0.77 to 1.03]) or the composite of CV and HF hospitalizations (RR 0.98 [0.81 to 1.19]).  Subgroup analysis found significant HTE for hospitalizations between those studies that used right ventricular/pulmonary pressure monitoring versus impedance-based monitoring (I2 = 87.1 %, Chi2 = 7.75, p = 0.005).  Regression analysis found no relationship between the log rate ratio of remote monitoring's effect on mortality, CV hospitalization or HF hospitalization, and mean follow-up time.  Compared to standard of care (SOC), remote monitoring using implantable devices did not reduce mortality, CV, or HF hospitalizations.  However, right ventricular/pulmonary pressure monitoring may reduce HF hospitalizations, which will need to be investigated in future studies.  These researchers stated that additional studies, especially those focused on monitoring of hemodynamic parameters, will aid in elucidating the role for remote monitoring.  This includes the GUIDE-HF trial, a follow-up to the CHAMPION trial (Abraham et al, 2011), which is poised to enroll 3,600 patients in order to power for mortality.

The authors stated that one limitation of this meta-analysis was the RCT heterogeneity observed among the hospitalization outcomes.  The studies were performed slightly differently, using a variety of remote monitoring devices/parameters.  Based on the findings using hemodynamic pressure measurements, more studies examining intracardiac or PA pressure monitoring may show that this specific measure is beneficial.  Another limitation of this meta-analysis was the outcome congruence and powering.  Mortality was included in this analysis given that the data were reported in each, yet it was not the primary outcome of the individual RCTs; and these studies were not powered to detect differences in mortality.  Larger enrollment and follow-up time would be required, yet this is not always feasible given the nature of the patient HF severity (often NYHA classes III to IV) and including those who require implantable devices such as ICD/CRT-Ds or PA pressure monitors.  Furthermore, not every study reported HF hospitalizations, with some only including cardiovascular hospitalizations (any hospitalization for arrhythmia, HF, MI, etc.).  Ideally, studies would report both measures (in addition to all-cause hospitalization) to determine the specific benefit of remote monitoring thereby defining reduction of types of hospitalizations, if any.

Heywood et al (2023) stated that therapy guided by PA pressure monitoring reduces PAP and HFH during the 1st year; however, the durability of safety and effectiveness through 2 years is unknown.  The CardioMEMS Post-Approval Study examined if safety and benefits were generalized and sustained.  Enrollment at 104 centers in the U.S. included 1,200 patients with NYHA Class III symptoms on recommended HF therapies with prior HFH.  Therapy was adjusted toward PA diastolic pressure 8 to 20 mmHg.  Intervention frequency and PA pressure reduction were most intense during first 90 days, with sustained reduction of PA diastolic pressure from baseline 24.7 mmHg to 21.0 at 1 year and 20.8 at 2 years for all patients.  Patients completing t2-year follow-up (n = 710) showed similar 2-year reduction (23.9 to 20.8 mmHg), with reduction in PA mean pressure (33.7 to 29.4 mmHg) in patients with reduced left ventricular ejection.  The HFH rate was 1.25 events/patient/year before sensor implant, 0.54 at 1 year, and 0.37 at 2 years, with 59 % of patients free of HFH during follow-up.  The authors concluded that reduction in PA pressures and hospitalizations were early and sustained during 2 years of PA pressure-guided management, with no signal of safety concerns regarding the implanted sensor.

The authors stated that the main drawback of this trial was its single-arm design, with patients serving as their own controls.  The magnitude of reduced HFH following PA sensor implantation should be interpreted with caution because no concomitant control group was available.  The impact of hemodynamic-guided care across study designs suggested the generalizability of effectiveness into real-world settings.  The PAS protocol suggested that PAP be reduced to a euvolemic range.  However, not all patients reached this goal because of symptomatic hypotension or worsening renal dysfunction, and it is unclear when the goal should be more modest or simply pursued over a longer time course with more escalation of therapies other than diuretics.  Although ACE-I/ARB/ARNI (angiotensin receptor-neprilysin inhibitor) use was not optimal at baseline, this therapy may have been limited by concomitant advanced chronic kidney disease or hypotension.  Furthermore, hospitalization rates could have been affected by patients’ deaths or study withdrawal, but analyses using only patients competing 2-year follow-up were very similar to those using the whole population.

Curtain et al (2022) carried out a meta-analysis of RCTs of IHM-guided care.  PubMed and Ovid Medline were searched for RCTs of IHM in patients with HF.  Outcomes were examined in total (1st and recurrent) event analyses.  A total of 5 trials comparing IHM-guided care with SOC alone were identified and included 2,710 patients across EF ranges.  Data were available for 628 patients (23.2 %) with HF with preserved EF (HFpEF) (EF 50 % or greater) and 2,023 patients (74.6 %) with HF with a reduced EF (HFrEF) (EF less than 50 %).  Chronicle, CardioMEMS and HeartPOD IHMs were used.  In all patients, regardless of EF, IHM-guided care reduced total HF hospitalizations (HR 0.74, 95 % CI: 0.66 to 0.82) and total worsening HF events (HR 0.74, 95 % CI: 0.66 to 0.84).  In patients with HFrEF, IHM-guided care reduced total worsening HF events (HR 0.75, 95 % CI: 0.66 to 0.86).  The effect of IHM-guided care on total worsening HF events in patients with HFpEF was uncertain (fixed-effect model: HR 0.72, 95 % CI: 0.59 to 0.88; random-effects model: HR 0.60, 95 % CI: 0.32 to 1.14).  IHM-guided care did not reduce mortality (HR 0.92, 95 % CI: 0.71 to 1.20).  IHM-guided care reduced all-cause mortality and total worsening HF events (HR 0.80, 95 % CI: 0.72 to 0.88).  The authors concluded that in patients with HF across all EFs, IHM-guided care reduced total HF hospitalizations and worsening HF events.  This benefit was consistent in patients with HFrEF but not consistent in HFpEF.  These researchers stated that further trials with pre-specified analyses of patients with an EF of 50 % or greater are needed.

Dannenberg et al (2023) stated that mitral valve and tricuspid valve regurgitations are associated with significant morbidity and mortality and are increasingly treated interventionally.  CardioMEMS is a transcutaneously implanted pressure sensor placed in the PA that allows invasive measurement of PAP and cardiac output (CO).  In a proof-of-concept study, these researchers observed hemodynamic changes as determined by CardioMEMS following transcatheter atrio-ventricular (AV) valve interventions, evaluated the additional value of CardioMEMS on top of echocardiography, and examined a potential effect of CardioMEMS on outcome.  Patients treated with transcatheter mitral or tricuspid valve interventions (mitral: TMVR, tricuspid: TTVR) or bi-caval valve implantation (bi-CAVI) were recruited.  All patients were followed for 12 months.  A total of 36 patients were included (4 with CardioMEMS, 32 controls).  Patients with CardioMEMS were monitored before intervention and 3 to 12 months thereafter (1 received TMVR, 1 bi-CAVI, 1 both TMVR and TTVR, and 1 isolated TTVR).  CardioMEMS group: In both patients with TMVR and in the patient with bi-CAVI, mean PAP decreased (all p < 0.001) and CO increased significantly (both TMVR p < 0.001 and bi-CAVI p = 0.006) while functional parameters, echocardiography, and NT-proBNP were difficult to interpret, unreliable, or both.  Changes following TTVR remained inconclusive.  The authors concluded that invasive monitoring using CardioMEMS provided important information following mitral and tricuspid valve interventions.  Such data pave the way for a deeper understanding of the prerequisites for optimal patient selection and management for catheter-based interventions.

The authors stated that this study had several drawbacks.  This was a small case-series proof-of concept study from a single center; thus, results should be interpreted as hypothesis-generating.  CardioMEMS measurements were not compared with conventional right heart catheterization beyond baseline measurements, especially because right-heart catheter is associated with risk after TTVR.  The patients provided a varying amount of CardioMEMS data.  While 1 patient sometimes even provided data twice-daily, others provided data only twice-weekly.  Therefore, the amount of data collection time-points varied between patients, which may have biased the statistical analysis.  Comparison of data from observational periods may be statistically significant but may not always lead to clinical consequences.  Furthermore, it must be acknowledged that the CardioMEMS Cardiac Output algorithm has not yet been validated.  The corresponding study (Validation of CardioMEMS HF System Cardiac Output Algorithm IDE [VICTOR]) is currently in progress.

Brugts, et al. (2023) reported the results of MONITOR-HF, an open-label, randomized trial, done in 25 centers in the Netherlands. Eligible patients had chronic heart failure of New York Heart Association class III and a previous heart failure hospitalization, irrespective of ejection fraction. Patients were randomly assigned (1:1) to CardioMEMS-HF or standard care. All patients were scheduled to be seen by their clinician at 3 months and 6 months, and every 6 months thereafter, up to 48 months. The primary endpoint was the mean difference in the Kansas City Cardiomyopathy Questionnaire (KCCQ) overall summary score at 12 months. All analyses were by intention-to-treat. Between April 1, 2019, and Jan 14, 2022, investigators randomly assigned 348 patients to either the CardioMEMS-HF group (n=176 [51%]) or the control group (n=172 [49%]). The median age was 69 years (IQR 61-75) and median ejection fraction was 30% (23-40). The difference in mean change in KCCQ overall summary score at 12 months was 7·13 (95% CI 1·51-12·75; p=0·013) between groups (+7·05 in the CardioMEMS group, p=0·0014, and -0·08 in the standard care group, p=0·97). In the responder analysis, the odds ratio (OR) of an improvement of at least 5 points in KCCQ overall summary score was OR 1·69 (95% CI 1·01-2·83; p=0·046) and the OR of a deterioration of at least 5 points was 0·45 (0·26-0·77; p=0·0035) in the CardioMEMS-HF group compared with in the standard care group. The freedom of device-related or system-related complications and sensor failure were 97·7% and 98·8%, respectively. Limitations of MONITOR-HF include the study was open-label, unblinded, and had a non-implanted control group. This design has inherent limitations because placebo effects could have differentially affected KCCQ score changes in both study groups. Another limitation is that the trial was not powered for between-group comparison of mortality rates. A larger sample size, longer follow-up period, or a combination of the two would have been required to assess mortality benefits (Angermann, 2023). It is not known whether the results of this trial can be generalized beyond the Dutch healthcare system.

Home Blood Pressure Monitor for Hypertension Screening in Adults

The U.S. Preventive Services Task Force (2015) recommends screening for high blood pressure in adults aged 18 years or older. The USPSTF recommends obtaining measurements outside of the clinical setting for diagnostic confirmation before starting treatment. The Task Force states that ambulatory blood pressure monitoring and home blood pressure monitoring may be used to confirm a diagnosis of hypertension after initial screening. The USPSTF found convincing evidence that ambulatory blood pressure monitoring is the best method for diagnosing hypertension. Although the criteria for establishing hypertension varied across studies, there was significant discordance between the office diagnosis of hypertension and 12- and 24-hour average blood pressures using ambulatory blood pressure monitoring, with significantly fewer patients requiring treatment based on ambulatory blood pressure monitoring. Elevated ambulatory systolic blood pressure was consistently and significantly associated with increased risk for fatal and nonfatal stroke and cardiovascular events, independent of office blood pressure. For these reasons, the USPSTF recommends ambulatory blood pressure monitoring as the reference standard for confirming the diagnosis of hypertension. The USPSTF states that home blood pressure monitoring using appropriate protocols is an alternative method of confirmation if ambulatory blood pressure monitoring is not available.  

According to the Centers for Disease Control and Prevention (CDC, 2013), patients should only use monitors that have been properly validated and tested for accuracy, passing at least 1 accepted standardized international testing protocol.  The 3 widely accepted validation protocols are from the Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society (BHS), and the European Hypertension Society (EHS).  The CDC noted that not all available home BP monitors have passed these validation tests.

Automated Oscillometer Blood Pressure Monitors

Barker et al (2000) stated that according to the criteria of the British Hypertension Society, neither the Dinamap 8100 nor the Omron M1 can be recommended for use in children in clinical situations in which accuracy of the absolute measurement is required.

Beaubien and colleagues (2002) reported that the Dinamap yields inaccurate estimates of both systolic and diastolic BP even under standardized, and thus optimal, conditions.  This inaccuracy is exaggerated at higher BP (over 160/90 mm Hg), although the number of measurements at higher pressures was small.  The authors recommended that this device not be used when accurate BP measurement is needed for therapeutic decision-making.

Chang and colleagues (2003) evaluated the variability in observed BP associated with use of the Dinamap monitor (Dinamap PRO 100) and estimated the contributions of various factors to that variability.  In 60 volunteers (30 aged 23 to 35 years and 30 aged 54 to 82 years), the authors obtained 30 simultaneous paired BP measurements in both arms at 1-min intervals.  Variability, defined as the between-arm difference in BP measurements, was analyzed using a mixed-effects linear regression model.  A total of 1,800 paired BP measurements were obtained.  These researchers found that only 50 % of paired simultaneous BP measurements obtained were in agreement within 4 mm Hg for systolic BP or within 3 mm Hg for diastolic BP.  Residual variability, attributable to the intrinsic inaccuracy of the device, accounted for 64 to 82 % of the total systolic and diastolic BP variability.  The majority of variability in BP measurement was due to the device as used under the study conditions.

Textor et al (2003) reported that 26 % (62 of 238) potential donors with excellent kidney function were mis-classified as hypertensive with clinic oscillometric measurements (Dinamap) alone.  Ramanathan et al (2003) claimed that there is no role for standard automated oscillometric devices (Dinamap) in the calculation of ankle-brachial pressure index in the vascular clinic.

Afzali et al (2004) examined if there are differences in BP measurements taken using either automated oscillometric machines (Dinamap BP8800 and Omron Hem 713) or a random zero Hawskley sphygmomanometer in stable healthy renal transplant outpatients.  These investigators concluded that there were no significant observer bias or cardiovascular artifacts.  Intra-machine variability was small.  Blood pressure measurements using Dinamap and Omron could lead to a difference of up to 30 mm Hg higher or 15 mm Hg lower than Hawskley random zero BP readings.  Though widely used for convenience, automated oscillometric measures of BP in the renal transplant clinic are not optimal.

Dannevig et al (2005) concluded that BP should preferably be measured invasively in severely ill neonates and preterm infants, being aware of pitfalls with measurements using different oscillometer monitors and the size/arm circumference of the infant.

The BpTRU is an automated device that takes serial BP measurements in a physician’s office.  The Canadian Agency for Drugs and Technologies in Health (Allison, 2006) stated that preliminary data from non-randomized, uncontrolled studies suggested that the average of 5 BP measurements by means of the BpTRU, taken while the patient is alone, more reliably reflects resting BP compared to standard manual measurements taken with a stethoscope and sphygmomanometer.  Moreover, the report noted that more controlled studies are needed to compare BpTRU measurements at specific interval settings to standard measurements taken by trained clinicians across a spectrum of patients.  This evidence is needed before specific recommendations can be made in guidelines regarding which BP monitor should be used preferentially in a physician’s office.

Fischell et al (2010) conducted the first clinical studies of intracardiac ST-segment monitoring in ambulatory humans.  The authors reported that intracardiac monitoring was performed in 37 patients at high risk for acute coronary syndromes and the implanted monitor continuously evaluated ST segments as sensed by a conventional pacemaker right ventricle apical lead.  Patients were alerted to detected ischemic events.  The patients were followed for a median of 1.52 years.  Four patients had ST segment changes of greater than or equal to 3 standard deviations of their normal daily range, in the absence of an elevated heart rate.  In combination with immediate hospital monitoring, the results led to angiogram and/or intravascular ultrasonographic confirmation of thrombotic coronary occlusion/ruptured plaque.  The authors concluded that shifts exceeding 3 standard deviations from a patient’s daily intracardiac ST-segment range may be a sensitive/specific marker for thrombotic coronary occlusion and that patient alerting was associated with a median alert-to-door time of 19.5 minutes for patients at high risk of recurrent coronary syndromes, who typically present with 2 to 3 hour delays.

See US Blood Pressure Validated Device Listing for blood pressure measurement devices that have been validated for clinical accuracy as determined through an independent review process.

AngelMed Guardian

The AngelMed Guardian System is an implantable cardiac device that has not received U.S. Food and Drug Administration (FDA) approval. It is suggested to measure ST elevation changes and possible impending heart attack via real-time ECG. The system includes an internal implantable device, approximately the size of a pacemaker, with a lead placed into the heart, a pager and a programming device that monitors the electrical activity of the heart. A physician programs the device to recognize specific changes in the heart signals. The pager is worn by the individual at all times. When the system detects changes in the heart’s predetermined electrical signals, the pager vibrates, beeps and flashes, alerting the individual to seek immediate medical attention. Information from the device can be retrieved by a computer for analysis by a physician. 

The AngelMed Guardian implantable device records cardiac data and detects ischemic events through use of a standard pacemaker intracardiac lead placed in the right ventricular apex.  The AngelMed Guardian detects acute ischemic events by analyzing ST-segment shifts, and if a shift is detected as greater than a heart rate-dependent programmable threshold, the device will generate an emergency alert signal.  As of 2009, the AngelMed Guardian had been implanted in 55 people in the United States and Brazil (Hopenfeld et al, 2009). 

The AngelMed Guardian remains an investigational device in the United States (AngelMed, 2012).  Currently, a prospective, randomized multicenter study of subjects with a high-risk of having a myocardial infarction (MI) due to acute coronary syndrome or bypass surgery is underway.  Subjects are being recruited in to the AngelMed for Early Recognition and Treatment of STEMI (ALERTS) Study, which has an open-label, crossover design; the primary efficacy objective is to determine whether the Guardian System reduces the composite of cardiac or unexplained death, new Q-wave MI and time-to-door for a confirmed occlusive event at a medical facility (Angel Medical Systems, 2012).

Non-Invasive Measurement of Central Blood Pressure

Laugesen et al (2013) noted that the SphygmoCor is used for non-invasive assessment of ascending aortic BP.  However, the validity of the SphygmoCor transfer function had not been tested in an exclusively type 2 diabetic patient sample.  Calibration with systolic and diastolic brachial BP has previously been associated with substantial imprecision of central BP estimates.  These investigators hypothesized that different non-invasive calibration strategies might improve the accuracy of the estimated ascending aortic BPs.  In 34 patients with type 2 diabetes, these researchers estimated ascending aortic systolic BP (SBP) and distolic BP (DBP) using the SphygmoCor device and compared these data with invasively recorded data.  The validity of the transfer function was assessed by calibrating with invasively recorded DBP and mean BP (MBP).  The influence of non-invasive calibration strategies was assessed by calibrating with brachial oscillometric SBP+DBP versus DBP+MBP using a form factor (ff) of 0.33 and 0.40, respectively.  When calibrating with invasive BP, the difference between estimated and invasively measured ascending aortic SBP and DBP was -2.3 ± 5.6/1.0 ± 0.9 mm Hg.  When calibrating with oscillometric brachial BPs, the differences were -9.6 ± 8.1/14.1 ± 6.2 mm Hg (calibration with SBP and DBP), -8.3 ± 11.7/13.9 ± 6.1 mm Hg (DBP and MBP; ff = 0.33), and 1.9 ± 12.2/14.1 ± 6.2 mm Hg (DBP and MBP; ff = 0.40), respectively.  Calibration with the average of 3 brachial BPs did not improve accuracy.  The authors concluded that the SphygmoCor transfer function seems valid in patients with type 2 diabetes.  They stated that non-invasive calibration with DBP and MBP (ff = 0.40) enables accurate estimation of mean ascending aortic SBP at the group level; however, the wide limits of agreement indicate limited accuracy in the individual patient.

Omboni et al (2015) compared central BP and vascular indices estimated non-invasively over the 24 hours between normotensive volunteers and hypertensive patients by a pulse wave analysis of ambulatory BP recordings.  Digitalized waveforms obtained during each brachial oscillometric BP measurement were stored in the device memory and analyzed by the validated Vasotens technology.  Averages for the 24 hours and for the awake and asleep sub-periods were computed.  A total of 142 normotensives and 661 hypertensives were evaluated.  Overall, 24-hour central BP, pulse wave velocity (PWV), and aortic augmentation index (AI) were significantly higher in the hypertensive group than in the normotensive group (119.3 versus 105.6 mm Hg for SBP, 75.6 versus 72.3 mm Hg for DBP, 10.3 versus 10.0 m/sec for aortic PWV, -9.7 versus -40.7 % for peripheral AI, and 24.7 versus 11.0 % for aortic AI), whereas reflected wave transit time (RWTT) was significantly lower in hypertensive patients (126.6 versus 139.0 ms).  After adjusting for confounding factors a statistically significant between-group difference was still observed for central BP, RWTT, and peripheral AI.  All estimates displayed a typical circadian rhythm.  The authors concluded that non-invasive assessment of 24-hour arterial stiffness and central hemodynamics in daily life dynamic conditions may help in assessing the arterial function impairment in hypertensive patients.

Xiao et al (2015) examined the differences in central hemodynamic indices between hypertensive and normotensive subjects and identified the BP index that the most strongly correlated with arterial stiffness and vascular damage markers.  A cohort of 820 hypertensive patients and 820 normotensive individuals matched for age and gender were enrolled in this study.  These researchers measured carotid-femoral and carotid-radial PWV, aortic AI and central BP using pulse wave analysis and applanation tonometry.  Plasma homocysteine (HCY), high-sensitivity C-reactive protein (hsCRP) and N-terminal pro-B-type natriuretic peptide (NT-proBNP) were also tested in these subjects.  In both hypertensive and normotensive subjects, the central SBP and pulse pressure (PP) were significantly lower than brachial SBP and PP; this PP amplification was significantly lower in the normotensives (9.85 +/- 6.55 mm Hg) than in the hypertensives (12.64 +/- 6.69 mm Hg), but the amplification ratios were comparable between the 2 groups.  Blood pressure and age were closely related with aortic arterial stiffness.  Compared with normotensive subjects, hypertensive subjects had higher carotid-femoral PWV and AI, and showed significantly lowered PP amplification ratio with age.  Central PP was more strongly related to arterial stiffness and vascular damage markers than the other pressure indices.  Multi-variate analyses revealed that carotid-femoral PWV and aortic AI were strongly influenced by central PP but not by the mean BP or brachial PP.  The authors concluded that central PP is a more direct indicator of central arterial stiffness and a better marker of vascular aging than other BP variables.  They stated that these findings support the use of central BP as a treatment target in future trials.

The Conduit Artery Function Evaluation (CAFE) study, a substudy of the Anglo-Scandinavian Cardiac Outcomes Trial (ASCOT), examined the impact of 2 different BP lowering-regimens (atenolol+/-thiazide-based versus amlodipine+/-perindopril-based therapy) on derived central aortic pressures and hemodynamics (Williams, et al., 2006). The CAFE study recruited 2199 patients in 5 ASCOT centers. Radial artery applanation tonometry and pulse wave analysis (Sphygmocor) were used to derive central aortic pressures and hemodynamic indexes on repeated visits for up to 4 years. Most patients received combination therapy throughout the study. Despite similar brachial systolic BPs between treatment groups (Delta0.7 mm Hg; 95% CI, -0.4 to 1.7; P=0.2), there were substantial reductions in central aortic pressures with the amlodipine regimen (central aortic systolic BP, Delta 4.3 mm Hg; 95% CI, 3.3 to 5.4; P<0.0001; central aortic pulse pressure, Delta 3.0 mm Hg; 95% CI, 2.1 to 3.9; P<0.0001). Cox proportional-hazards modeling showed that central pulse pressure was significantly associated with a post hoc-defined composite outcome of total cardiovascular events/procedures and development of renal impairment in the CAFE cohort (unadjusted, P<0.0001; adjusted for baseline variables, P<0.05). The investigators concluded that BP-lowering drugs can have substantially different effects on central aortic pressures and hemodynamics despite a similar impact on brachial BP. Moreover, central aortic pulse pressure may be a determinant of clinical outcomes, and differences in central aortic pressures may be a potential mechanism to explain the different clinical outcomes between the 2 BP treatment arms in ASCOT. An accompanying editorial (Oparil, et al., 2006) stated that, "in the context of clinical trials, radial tonometry adds to our knowledge of the pharmacodynamic effects of vasoactive drugs. . . . . Whether radial tonometry should be performed routinely in individual patients as a diagnostic or therapeutic indicator, however, remains a matter of considerable debate. At present, the technique is probably not quite ready for 'prime time' in routine clinical practice." 

Weber et al (2011) reported that increased arterial wave reflections are independent predictors of renal as well as cardiorenal events in patients with chronic kidney disease.  These investigators prospectively quantified wave reflections as pressure augmentation (AP) and augmentation index (AIx) using radial applanation tonometry and a transfer function, in 111 patients (mean age of 53.6 years; 71 men, 31 diabetics) with chronic kidney disease not requiring dialysis.  Primary end-point was a composite of doubling of serum creatinine, need for dialysis, and transplantation.  Secondary end-point was a combination of renal and cardiovascular events.  After a mean follow-up of 41.3 months, 37 and 46 patients reached the primary and the secondary end-point.  AIx and AP proved statistically significant predictors of the renal endpoint (p < 0.05 for all), with a 2.5- and 3-fold increased risk for patients in the highest versus the lowest tertile, respectively.  After adjustment for mean blood pressure (MBP), age, gender, diabetes, serum albumin, hemoglobin, urine albumin/creatinine ratio, and renal function at baseline, AIx (hazard ratio [HR] 1.474/10 % increase in AIx, p = 0.04) as well as AP (HR 1.559/10 mm Hg increase in AP, p = 0.04) remained significant predictors of the renal end-point.  In addition, AIx and AP were significant (p < 0.05) predictors of the combined cardiorenal end-point in univariate analysis and multivariable models.  An commentary noted that pulse wave velocity was not measured in this study (Payne, 2011).  The commentator concluded: "Where do we go from here?  The authors note that AIx may be a suitable target for intervention, and indeed propose that a trial be undertaken to determine whether therapeutically targeting wave reflections independent of blood pressure reduction would lessen CKD progression.  This may also partly address the unanswered question of causality.  Unfortunately, we still lack any suitable pharmacological interventions to achieve this, as current options for lowering AIx all have significant blood pressure lowering effects.  Furthermore, given the inextricable relationship between AIx and blood pressure, targeting one of these factors and not the other is perhaps inappropriate, and indeed the current findings may support the use of antihypertensive agents which also reduce AIx.  Regardless of the therapeutic intervention employed, measuring AIx may facilitate earlier and more aggressive targeting of at-risk patients, and larger studies are certainly justified to explore the prognostic value of AIx in more detail".

Sharman et al (2013) sought to determine the usefulness of central BP to guide hypertension management.  The investigators conducted a prospective, open-label, blinded–end point study in 286 patients with hypertension randomized to treatment decisions guided by best-practice usual care (n = 142; using office, home, and 24-hour ambulatory BP) or, in addition, by central BP intervention (n = 144; using SphygmoCor).  Therapy was reviewed every 3 months for 12 months, and recommendations were provided to each patient and his/her doctor on anti-hypertensive medication titration.  Outcome measures were as follows: medication quantity (daily defined dose), quality of life, and left ventricular mass (3-dimensional echocardiography).  There was 92 % compliance with recommendations on medication titration, and quality of life improved in both groups (post-hoc p < 0.05).  For usual care, there was no change in daily defined dose (all p > 0.10), but with intervention there was a significant stepwise decrease in daily defined dose from baseline to 3 months (p = 0.008) and each subsequent visit (all p < 0.001).  Intervention was associated with cessation of medication in 23 (16 %) patients versus 3 (2 %) in usual care (p < 0.001).  Despite this, there were no differences between groups in left ventricular mass index, 24-hour ambulatory BP, home systolic BP, or aortic stiffness (all p > 0.05).  The investigators concluded that guidance of hypertension management with central BP results in a significantly different therapeutic pathway than conventional cuff BP, with less use of medication to achieve BP control and no adverse effects on left ventricular mass, aortic stiffness, or quality of life.  An accompanying editorial (Avolio et al, 2013) commented that "there is still insufficient evidence for central aortic BP to be integrated in guidelines for treatment and management of hypertension".  The editorialist stated that trials are required to assess hard end-points, where subjects are followed up for a longer period (of the order of 5 years, similar to many other intervention studies).  In addition, the design should be expanded where central aortic BP is measured in all subjects, but where one group is assessed by measurements of brachial cuff pressure but blind to the results of central BP and the other groups guided by the results of central BP but blind to the results of brachial BP. 

Shaikh and colleagues (2016) stated that the relations of measures of arterial stiffness, pulsatile hemodynamic load, and endothelial dysfunction to atrial fibrillation remain poorly understood.  To better understand the pathophysiology of atrial fibrillation, these investigators examined associations between non-invasive measures of vascular function and new-onset atrial fibrillation.  The study sample included participants aged greater than or equal to 45 years from the Framingham Heart Study offspring and 3rd-generation cohorts.  Using Cox proportional hazards regression models, these researchers examined relations between incident atrial fibrillation and tonometry measures of arterial stiffness (carotid-femoral pulse wave velocity), wave reflection (augmentation index), pressure pulsatility (central pulse pressure), endothelial function (flow-mediated dilation), resting brachial arterial diameter, and hyperemic flow.  Atrial fibrillation developed in 407/5,797 participants in the tonometry sample and 270/3,921 participants in the endothelial function sample during follow-up (median of 7.1 years, maximum of 10 years).  Higher augmentation index (hazard ratio, 1.16; 95 % CI: 1.02 to 1.32; p = 0.02), baseline brachial artery diameter (hazard ratio, 1.20; 95 % CI: 1.01 to 1.43; p = 0.04), and lower flow-mediated dilation (hazard ratio, 0.79; 95 % CI: 0.63 to 0.99; p = 0.04) were associated with increased risk of incident atrial fibrillation.  Central pulse pressure, when adjusted for age, sex, and hypertension (hazard ratio, 1.14; 95 % CI: 1.02 to 1.28; p = 0.02) was associated with incident atrial fibrillation.  Higher pulsatile load assessed by central pulse pressure and greater apparent wave reflection measured by augmentation index were associated with increased risk of incident atrial fibrillation.  The authors concluded that vascular endothelial dysfunction may precede development of atrial fibrillation; and these measures may be additional risk factors or markers of subclinical cardiovascular disease associated with increased risk of incident atrial fibrillation.

Current leading medical professional association guidelines on hypertension, heart failure, diabetes, renal disease and assessment of cardiovascular disease risk have no recommendation for non-invasive measurement of blood pressure by pulse waveform analysis.

Evensen and colleagues (2018) tested the hypothesis that the central aortic BP waveform may be used for non-invasive estimation of the intra-cranial pressure (ICP) waveform.  Simultaneous invasive ICP and radial artery BP waveforms were measured in 29 individuals with idiopathic normal pressure hydrocephalus (iNPH).  The central aortic BP waveforms were estimated from the radial artery BP waveforms using the SphygmoCor system.  For each individual, a transfer function estimate between the central aortic BP and the invasive ICP waveforms was found (intra-patient approach).  Thereafter, the transfer function estimate that gave the best fit was chosen and applied to the other individuals (inter-patient approach).  To validate the results, ICP waveform parameters were calculated for the estimates and the measured golden standard.  For the intra-patient approach, the mean absolute difference in invasive versus non-invasive mean ICP wave amplitude was 1.9 ± 1.0 mmHg among the 29 individuals.  Correspondingly, the inter-patient approach resulted in a mean absolute difference of 1.6 ± 1.0 mmHg for the 29 individuals.  The authors concluded that this method gave a fairly good estimate of the wave for about 1/3 of the individuals, but the variability was quite large.  They stated that this approach is therefore not a reliable method for use in clinical patient management.

Schultz and colleagues (2020) stated that many devices purport to measure central (aortic) BP as distinct from conventional brachial BP.  In a validation study, these researchers examined the accuracy of the Sphygmocor Xcel cuff device for measuring central BP.  A total of 296 patients (mean age of 61 ± 12 years) undergoing coronary angiography had simultaneous measurement of invasive central BP and non-invasive cuff-derived central BP using the Xcel cuff device (total n = 558 individual comparisons).  A sub-sample (n = 151) also had invasive brachial BP measured.  Methods were undertaken according to the Artery Society recommendations, and several calibration techniques to derive central systolic BP (SBP) were examined.  Minimum acceptable error was less than or equal to 5 ± less than or equal to 8 mm Hg.  Central SBP was significantly under-estimated, and with wide variability, when using the default calibration of brachial-cuff SBP and diastolic BP (DBP; mean difference ± SD, -7.7 ± 11.0 mm Hg).  Similar variability was observed using other calibration methods (cuff 33 % form-factor mean arterial pressure [MAP] and DBP, -4.4 ± 11.5 mm Hg; cuff 40 % form-factor MAP and DBP, 4.7 ± 11.9 mm Hg; cuff oscillo-metric MAP and DBP, -18.2 ± 12.1 mm Hg).  Only calibration with invasive central integrated MAP and DBP was within minimal acceptable error (3.3 ± 7.5 mm Hg).  The difference between brachial-cuff SBP and invasive central SBP was 3.3 ± 10.7 mm Hg.  A sub-sample analysis to determine the accuracy of central-to-brachial SBP amplification showed this to be over-estimated by the Xcel cuff device (mean difference 4.3 ± 9.1 mm Hg, p = 0.02).  The authors concluded that irrespective of cuff calibration technique, the Sphygmocor Xcel cuff device did not meet the Artery Society accuracy criteria for non-invasive measurement of central BP.

Mobile Health Tracking Devices

Mena and associates (2018) stated that mobile ECG monitoring is an emerging area that has received increasing attention in recent years, but still real-life validation for elderly residing in low and middle-income countries is scarce.  These researchers developed a wearable ECG monitor that is integrated with a self-designed wireless sensor for ECG signal acquisition.  It is used with a native purposely designed smartphone application, based on machine learning techniques, for automated classification of captured ECG beats from aged people.  When tested on 100 older adults, the monitoring system discriminated normal and abnormal ECG signals with a high degree of accuracy (97 %), sensitivity (100 %), and specificity (96.6 %).  The authors concluded that with further verification, the system could be useful for detecting cardiac abnormalities in the home environment and contribute to prevention, early diagnosis, and effective treatment of cardiovascular diseases, while keeping costs down and increasing access to healthcare services for older persons.

The author stated that the ECG monitoring and classification system described in this review had several potential drawbacks.  First, their system and most other mobile ECG monitors record a single-channel ECG signal, which provides more limited information than 12-lead ECG devices.  Nevertheless, a recent study found good correlation between smartphone ECG and 12-lead ECG data, before and after anti-arrhythmic drug therapy.  Second, despite high overall recognition, the precision of the neural network classifier was only 81.3 %, although false positive signals would be recognized by physician evaluation.  Third, the system provided timely detection of abnormal ECG patterns for further diagnosis by healthcare professionals; but did not identify specific types of cardiac disorders.  Finally, the system was tested using a relatively small sample (n = 100) at a single center and primarily included Venezuelan women; thus, the system performance characteristics might not be generalizable to other user populations.  Thus, these researchers stated that further studies are needed to extend use of mobile ECG monitoring to other geographically diverse elderly populations as well as provide a better characterization of heart rhythm abnormalities.

Modena and colleagues (2018) noted that cardiovascular disease remains the leading cause of death and disease worldwide.  As demands on an already resource-constrained healthcare system intensify, disease prevention in the future will likely depend on out-of-office monitoring of cardiovascular risk factors.  Mobile health tracking devices that can track BP and HR, in addition to new cardiac vital signs, such as physical activity level and PWV, offer a promising solution.  An initial barrier is the development of accurate and easily-scalable platforms.  These researchers made a customized smartphone application and used mobile health devices to track PWV, BP, HR, physical activity, sleep duration, and multiple lifestyle risk factors in 250 adults for 17 continual weeks.  Eligible subjects were identified by a company database and then were consented and enrolled using only a smartphone application, without any special training given.  Study participants reported high overall satisfaction, and 73 % of participants were able to measure BP and PWV, less than 1 hour apart, for at least 14 of 17 weeks.  The study population's BP, PWV, HR, activity levels, sleep duration, and the interrelationships among these measurements were found to closely match either population averages or values obtained from studies performed in a controlled setting.  The authors concluded that as a proof-of-concept, they demonstrated the accuracy and ease, as well as many challenges, of using mHealth technology to accurately track PWV and new cardiovascular vital signs at home.

In-Home Cardiovascular Monitoring System for Heart Failure

Conn and colleagues (2019) noted that there is a pressing need to reduce the hospitalization rate of HF patients to limit rising healthcare costs and improve outcomes.  Tracking physiologic changes to detect early deterioration in the home has the potential to reduce hospitalization rates through early intervention.  However, classical approaches to in-home monitoring have had limited success, with patient adherence cited as a major barrier.  These researchers presented a toilet seat-based cardiovascular monitoring system that has the potential to address low patient adherence as it does not require any change in habit or behavior.  The toilet seat-based cardiovascular monitoring system is an integrated electrocardiogram, ballistocardiogram, and photoplethysmogram that is capable of clinical-grade measurements of SBP, DBP, stroke volume (SV), and peripheral blood oxygenation (SpO2).  The toilet seat-based estimates of BP and SpO2 were compared to a hospital-grade vital signs monitor for 18 subjects over an 8-week period.  The estimated SV was validated on 38 normative subjects and 111 subjects undergoing a standard echocardiogram at a hospital clinic for any underlying condition, including HF.  Clinical grade accuracy was achieved for all of the seat measurements when compared to their respective gold standards.  The accuracy of DBP and SBP was 1.2 (SD 6.0) mm Hg (n = 112) and -2.7 (SD 6.6) mm Hg (n = 89), respectively; SV has an accuracy of -2.5 (SD 15.5) ml (n = 149) compared to an echocardiogram gold standard; SpO2 had an root mean square (RMS) error of 2.3 % (n = 91).  The authors concluded that a toilet seat-based cardiovascular monitoring system had been successfully demonstrated with BP, SV, and SpO2 accuracy consistent with gold standard measures.  This system would be uniquely positioned to capture trend data in the home that has been previously unattainable.  Demonstration of the clinical benefit of the technology requires additional algorithm development and future clinical trials, including those targeting a reduction in HF hospitalizations.

The authors stated that one drawback of this study was that the seat-based system has not been used extensively in the home-setting.  In each of these studies, the seat was set up for automatic detection and data acquisition upon subjects’ use with unattended data transmission to a cloud data-base.  There was no use of laboratory or clinic infra-structure for gathering seat data, and the seat was deployed exactly as it would be in the home.  While BP and SpO2 were measured over multiple weeks, the majority of subjects did not show significant shifts within this time frame.  Another drawback was that the limits of agreement for SV was similar to that of the echocardiogram.  It is unclear if the errors in the estimation of SV were due to the seat or the echocardiographic measure of the left ventricular outflow tract area.  As such, future studies will compare the seat’s estimate of SV to a gold standard cardiac MRI.  These researchers stated that future work will initially focus on larger scale studies to validate BP and SpO2 across a broader population.  As urination and defecation can shift BP, SV, and HR, detection algorithms will be developed and validated to remove these states from the analysis, ensuring that accurate daily trends at steady state are captured.  Subject identification using biometrics to enable truly passive monitoring in a multiple person household will also be developed.  Additionally, the possibility of removing the per-subject calibration required for BP and SpO2 estimation will be examined via the incorporation of easily measured subject-specific information (e.g., thigh thickness).  Body weight measurements on the seat have not yet been verified.  Future studies will examine the ability of machine learning to estimate body weight based on posture and body type.  This work and the afore-mentioned future studies will lead to a 2-phased clinical trial where an alert-based system for early detection of deterioration will be developed with in-home seat data and subsequently validated with the goal of demonstrating a reduction in HF hospitalization rates.

Zoll Heart Failure and Arrhythmia Management System (HFAMS)

ZOLL Heart Failure and Arrhythmia Management System (HFAMS), a patch-based, wireless system that employs radiofrequency technology, is designed to aid physicians improve outcomes and reduce hospitalizations for patients with acute heart failure (HF) who have fluid management problems. It is a non-invasive and water-resistant sensor that can be worn by patients 24 hours a day for monitoring of pulmonary fluid levels as an early indicator for heart failure decompensation. Once placed on a patient’s body, it continuously records patient data including heart rate (HR), heart rhythm (ECG), respiration rate, and thoracic fluid index. Physicians are notified according to pre-defined criteria to aid in the diagnosis and identification of various clinical events and/or trends; thus, allowing physicians to provide timely intervention if needed. Physicians can login to a unified portal to review the monitoring results.

There is a lack of evidence on the effectiveness of the ZOLL Heart Failure and Arrhythmia Management System (HFAMS) in improving the health outcomes of patients with HF.


References

The above policy is based on the following references:

  1. Abraham J, Bharmi R, Jonsson O, et al. Association of ambulatory hemodynamic monitoring of heart failure with clinical outcomes in a concurrent matched cohort analysis. JAMA Cardiol. 2019;4(6):556-563
  2. Abraham WT, Adamson PB, Bourge RC, et al.; CHAMPION Trial Study Group. Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: A randomised controlled trial. Lancet. 2011;377(9766):658-666.
  3. Abraham WT, Stough WG, Pina IL, et al. Trials of implantable monitoring devices in heart failure: Which design is optimal? Nat Rev Cardiol. 2014;11(10):576-585.
  4. Abraham WT. Disease management: Remote monitoring in heart failure patients with implantable defibrillators, resynchronization devices, and haemodynamic monitors. Europace. 2013;15 Suppl 1:i40-i46.
  5. Adamson PB, Abraham WT, Bourge RC, et al. CardioMEMS heart sensor allows monitoring of pressures to improve outcomes in NYHA Class III heart failure patients (CHAMPION) trial: Iimpact of hemodynamic guided care on patients with preserved ejection fraction. J Cardiac Fail. 2010;16(11):913.
  6. Afzali B, Haydar AA, Abbs IC, Goldsmith DJ. Measuring blood pressure in stable renal transplant recipients: What you measure depends on what you use. Nephron Clin Pract. 2004;97(3):c98-c102.
  7. Angermann CE. Remote pulmonary artery pressure monitoring in heart failure care: Part of the new normal? Lancet. 2023;401(10394):2088-2089.
  8. Airhart S, Badie N, Doyle M, et al. Assessing hemodynamic response to submaximal exercise in pulmonary arterial hypertension patients using an implantable hemodynamic monitor. J Heart Lung Transplant. 2021;40(6):430-434.
  9. Allison C. BpTRUTM blood pressure monitor for use in a physician’s office. Issues in Emerging Health Technologies Issue 86. Ottawa, ON: Canadian Agency for Drugs and Technologies in Health (CADTH); August 2006.
  10. American College of Surgeons. Statement on indications for the use of permanently implanted cardiac pacemakers. Bull Am Coll Surg. 1996;81(2):40.
  11. American Diabetes Association. (8) Cardiovascular disease and risk management. Diabetes Care. 2015;38 Suppl:S49-S57.
  12. Angel Medical Systems. AngelMed for Early Recognition and Treatment of STEMI (ALERTS). ClinicalTrials.gov. NLM ClinicalTrials.gov identifier: NCT00781118. Bethesda, MD: National Library of Medicine; June 2012.
  13. AngelMed. What is the AngelMed Guardian System [website]. Shrewsbury, NJ: Angel Medical Systems, Inc.;July, 2012. Available at: http://www.angel-med.com/index.php/patients-families/our-solution.html. Accessed: July 23, 2012.
  14. Angermann CE, Assmus B, Anker Sd, et al; for the MEMS-HF Investigators. Pulmonary artery pressure-guided therapy in ambulatory patients with symptomatic heart failure: The CardioMEMS European Monitoring Study for Heart Failure (MEMS-HF). Eur J Heart Fail. 2020;22(10):1891-1901.
  15. Assaad M, Sarsam S, Naqvi A, Zughaib M. CardioMems® device implantation reduces repeat hospitalizations in heart failure patients: A single center experience. JRSM Cardiovasc Dis. 2019;8:2048004019833290.
  16. Athilingam P, Jenkins BA, Zumpano H, Labrador MA. "Mobile technology to improve heart failure outcomes: A proof of concept paper". Appl Nurs Res. 2018;39:26-33.
  17. Barker ME, Shiell AW, Law CM. Evaluation of the Dinamap 8100 and Omron M1 blood pressure monitors for use in children. Paediatr Perinat Epidemiol. 2000;14(2):179-186.
  18. Beaubien ER, Card CM, Card SE, et al. Accuracy of the Dinamap 1846 XT automated blood pressure monitor. J Hum Hypertens. 2002;16(9):647-652.
  19. Benmira A, Perez-Martin A, Schuster I, et al. From Korotkoff and Marey to automatic non-invasive oscillometric blood pressure measurement: Does easiness come with reliability? Expert Rev Med Devices. 2016;13(2):179-189.
  20. Benza RL, Doyle M, Lasorda D, et al. Monitoring pulmonary arterial hypertension using an implantable hemodynamic sensor. Chest. 2019;156(6):1176-1186.
  21. Benza RL, Raina A, Abraham WT, et al. Pulmonary hypertension related to left heart disease: Insight from a wireless implantable hemodynamic monitor. J Heart Lung Transplant. J Heart Lung Transplant. 2015;34(3):329-337.
  22. Biederman RWW, Doyle M, Correa-Jaque P, et al. Integrated use of cardiac MRI and the CardioMEMS™ HF system in PAH: The utility of coincident pressure and volume in RV failure -- The NHLBI-VITA Trial. Cardiovasc Diagn Ther. 2019;9(5):492-501.
  23. Blomstrom-Lundqvist C, Liliemark J, Eriksson M. Measurement of pulmonary artery pressure in heart failure with implantable sensor. SBUs Comments No. 2018_01. Stockholm, Sweden: Swedish Office of Technology Assessment (SBU); January 2018.
  24. Booysen HL, Norton GR, Maseko MJ, et al. Aortic, but not brachial blood pressure category enhances the ability to identify target organ changes in normotensives. J Hypertens. 2013;31(6):1124-1130.
  25. Borlaug BA, Colucci WS. Treatment and prognosis of heart failure with preserved ejection fraction. UpToDate [online serial]. Waltham, MA: UpToDate; reviewed March 2017; July 2020.
  26. Bourge RC, Abraham WT, Adamson PB, et al.; COMPASS-HF Study Group. Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure: The COMPASS-HF study. J Am Coll Cardiol. 2008;51(11):1073-1079.
  27. Bradley EA, Jassal A, Moore-Clingenpeel M, et al. Ambulatory Fontan pressure monitoring: Results from the implantable hemodynamic monitor Fontan feasibility cohort (IHM-FFC). Int J Cardiol. 2019;284:22-27.
  28. Brugts JJ, Radhoe SP, Clephas PRD, et al.; MONITOR-HF investigators. Remote haemodynamic monitoring of pulmonary artery pressures in patients with chronic heart failure (MONITOR-HF): A randomised clinical trial. Lancet. 2023;401(10394):2113-2123.
  29. Centers for Disease Control and Prevention (CDC). Self-measured blood pressure monitoring: Action steps for public health practitioners. Atlanta, GA: CDC; 2013.
  30. Chang JJ, Rabinowitz D, Shea S. Sources of variability in blood pressure measurement using the Dinamap PRO 100 automated oscillometric device. Am J Epidemiol. 2003;158(12):1218-1226.
  31. Chaudhry SI, Mattera JA, Curtis JP, et al. Telemonitoring in patients with heart failure. N Engl J Med. 2010;363(24):2301-2309.
  32. Chaudhry SI, Phillips CO, Stewart SS, et al. Telemonitoring for patients with chronic heart failure: A systematic review. J Card Fail. 2007;13(1):56-62.
  33. Chirinos JA, Kips JG, Jacobs DR Jr, et al. Arterial wave reflections and incident cardiovascular events and heart failure: MESA (Multiethnic Study of Atherosclerosis). J Am Coll Cardiol. 2012;60(21):2170-2177.
  34. Chow EY, Chlebowski AL, Chakraborty S, et al. Fully wireless implantable cardiovascular pressure monitor integrated with a medical stent. IEEE Trans Biomed Eng. 2010;57(6):1487-1496.
  35. Cleland JG, Louis AA, Rigby AS, et al.; TEN-HMS Investigators. Noninvasive home telemonitoring for patients with heart failure at high risk of recurrent admission and death: The Trans-European Network-Home-Care Management System (TEN-HMS) study. J Am Coll Cardiol. 2005;45(10):1654-1664.
  36. Colucci WS. Investigational and emerging strategies for management of heart failure. UpToDate [online serial]. Waltham, MA: UpToDate; reviewed March 2021; March 2022.
  37. Conn NJ, Schwarz KQ, Borkholder DA. In-home cardiovascular monitoring system for heart failure: Comparative study. JMIR Mhealth Uhealth. 2019;7(1):e12419.
  38. Cordisco ME, Benjaminovitz A, Hammond K, Mancini D. Use of telemonitoring to decrease the rate of hospitalization in patients with severe congestive heart failure. Am J Cardiol. 1999;84(7):860-862, A8.
  39. Curtain JP, Lee MMY, McMurray JJ, et al. Efficacy of implantable haemodynamic monitoring in heart failure across ranges of ejection fraction: A systematic review and meta-analysis. Heart. 2022 Dec 15 [Online ahead of print].
  40. Dang S, Dimmick S, Kelkar G. Evaluating the evidence base for the use of home telehealth remote monitoring in elderly with heart failure. Telemed J E Health. 2009;15(8):783-796.
  41. Dannenberg V, Koschutnik M, Dona C, et al. Monitoring of mitral- and tricuspid valve interventions with CardioMEMS: Insights beyond imaging. Eur J Clin Invest. 2023 Jan 29 [Online ahead of print].
  42. Dannevig I, Dale HC, Liestol K, Lindemann R. Blood pressure in the neonate: Three non-invasive oscillometric pressure monitors compared with invasively measured blood pressure. Acta Paediatr. 2005;94(2):191-196.
  43. Daskalopoulou SS, Rabi DM, Zarnke KB, et al. The 2015 Canadian Hypertension Education Program recommendations for blood pressure measurement, diagnosis, assessment of risk, prevention, and treatment of hypertension. Can J Cardiol. 2015;31(5):549-568.
  44. de Lusignan S, Meredith K, Wells S, et al. A controlled pilot study in the use of telemedicine in the community on the management of heart failure--a report of the first three months. Stud Health Technol Inform. 1999;64:126-137.
  45. de Lusignan S, Wells S, Johnson P, et al. Compliance and effectiveness of 1 year's home telemonitoring. The report of a pilot study of patients with chronic heart failure. Eur J Heart Fail. 2001;3(6):723-730.
  46. Desai AS, Bhimaraj A, Bharmi R, et al. Ambulatory hemodynamic monitoring reduces heart failure hospitalizations in “real-world” clinical practice. J Am Coll Cardiol. 2017;69(19):2357-2365.
  47. Eguchi K, Kuruvilla S, Ishikawa J, et al. Correlations between different measures of clinic, home, and ambulatory blood pressure in hypertensive patients. Blood Press Monit. 2011;16(3):142-148.
  48. Evensen KB, O'Rourke M, Prieur F, et al. Non-invasive estimation of the intracranial pressure waveform from the central arterial blood pressure waveform in idiopathic normal pressure hydrocephalus patients. Sci Rep. 2018;8(1):4714.
  49. Fischell TA, Fischell DR, Avezum A, et al. Initial clinical results using intracardiac electrogram monitoring to detect and alert patients during coronary plaque rupture and ischemia. J Am Coll Cardiol. 2010;56(14):1089-1098.
  50. Givertz MM, Stevenson LW, Costanzo MR, et al; CHAMPION Trial Investigators. Pulmonary artery pressure-guided management of patients with heart failure and reduced ejection fraction. J Am Coll Cardiol. 2017;10;70(15):1875-1886.
  51. Go AS, Bauman MA, Coleman King SM, et al. An effective approach to high blood pressure control: A science advisory from the American Heart Association, the American College of Cardiology, and the Centers for Disease Control and Prevention. J Am Coll Cardiol. 2014;63(12):1230-1238.
  52. Grancelli HO and Ferrante DC. Telephone interventions for disease management in heart failure. BMJ.  2007;334(7600):910-911.
  53. Gregoratos G, Cheitlin MD, Conill A, et al. ACC/AHA guidelines for implantation of cardiac pacemakers and antiarrhythmia devices: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). J Am Coll Cardiol. 1998;31(5):1175-1209.
  54. Hailey D, Ohinmaa A, Roine R. Evidence for the benefits of telecardiology applications: A systematic review. Health Technology Assessment 34. Edmonton, AB: Alberta Heritage Foundation for Medical Research (AHFMR); October 2004.
  55. Hajduczok AG, Muallem SN, Nudy MS, et al. Remote monitoring for heart failure using implantable devices: A systematic review, meta-analysis, and meta-regression of randomized controlled trials. Heart Fail Rev. 2022;27(4):1281-1300.
  56. Heywood JT, Jermyn R, Shavelle D, et al. Impact of practice-based management of pulmonary artery pressures in 2000 patients implanted with the CardioMEMS sensor. Circulation. 2017;135(16):1509-1517.
  57. Heywood JT, Zalawadiya S, Bourge RC; CardioMEMS Post-Approval Study Investigators. Sustained reduction in pulmonary artery pressures and hospitalizations during 2 years of ambulatory monitoring. J Card Fail. 2023;29(1):56-66.
  58. Ho C. Implantable hemodynamic monitoring (the Chronicle IHM system): Remote telemonitoring for patients with heart failure. Issues Emerg Health Technol. 2008; 111:1-4.
  59. Hopenfeld B, John MS, Fischell DR, et al. The Guardian: an implantable system for chronic ambulatory monitoring of acute myocardial infarction. J Electrocardiol. 2009;42(6):481-6.
  60. Horwitz L, Krumholz H. Strategies to reduce hospitalizations in patients with heart failure. UpToDate [online serial]. Waltham, MA: UpToDate; reviewed March 2017.
  61. James PA, Oparil S, Carter BL, et al. 2014 evidence-based guideline for the management of high blood pressure in adults: Report from the panel members appointed to the Eighth Joint National Committee (JNC 8). JAMA. 2014;311(5):507-520.
  62. Joshi R, Nair A. The utility of CardioMEMS, a wireless hemodynamic monitoring system in reducing heart failure related hospital readmissions. J Nurse Pract. 2021;17(3):267-272.
  63. Kampus P, Serg M, Kals J, et al. Differential effects of nebivolol and metoprolol on central aortic pressure and left ventricular wall thickness. Hypertension. 2011;57(6):1122-1128.
  64. Kitsiou S, Pare G, Jaana M. Effects of home telemonitoring interventions on patients with chronic heart failure: An overview of systematic reviews. J Med Internet Res. 2015;17(3):e63.
  65. Kitsiou S, Pare G, Jaana M. Systematic reviews and meta-analyses of home telemonitoring interventions for patients with chronic diseases: A critical assessment of their methodological quality. J Med Internet Res. 2013;15(7):e150.
  66. Koehler F, Winkler S, Schieber M, et al; on behalf of the Telemedical Interventional Monitoring in Heart Failure Investigators. Impact of remote telemedical management on mortality and hospitalizations in ambulatory patients with chronic heart failure: The Telemedical Interventional Monitoring in Heart Failure Study. Circulation. 2011;123(17):1873-1880.
  67. Krum H. Telemonitoring of fluid status in heart failure: CHAMPION. Lancet. 2011;377(9766):616-618.
  68. Laugesen E, Rossen NB, Peters CD, et al. Assessment of central blood pressure in patients with type 2 diabetes: A comparison between SphygmoCor and invasively measured values. Am J Hypertens. 2014;27(2):169-176.
  69. Magalski, A, Adamson P, Gadler F, et al. Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: A multicenter, 12-month follow-up study of patients with chronic heart failure. J Card Fail. 2002;8:63-70.
  70. Mancia G, Fagard R, Narkiewicz K, et al. 2013 ESH/ESC guidelines for the management of arterial hypertension: the Task Force for the Management of Arterial Hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC). Eur Heart J. 2013;34(28):2159-2219.
  71. Mazimba S, Ginn G, Mwansa H, et al. Pulmonary artery proportional pulse pressure (PAPP) index identifies patients with improved survival from the CardioMEMS implantable pulmonary artery pressure monitor. Heart Lung Circ. 2021;30(9):1389-1396.
  72. McKelvie RS, Moe GW, Ezekowitz JA, et al. The 2012 Canadian Cardiovascular Society heart failure management guidelines update: Focus on acute and chronic heart failure. Can J Cardiol. 2013;29(2):168-181.
  73. McMurray JJ, Adamopoulos S, Anker SD, et al.; ESC Committee for Practice Guidelines. ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2012: The Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2012 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association (HFA) of the ESC. Eur Heart J. 2012;33(14):1787-1847. 
  74. Mena LJ, Félix VG, Ochoa A, et al. Mobile personal health monitoring for automated classification of electrocardiogram signals in elderly. Comput Math Methods Med. 2018;2018:9128054.
  75. Modena BD, Bellahsen O, Nikzad N, et al. Advanced and accurate mobile health tracking devices record new cardiac vital signs. Hypertension. 2018;72(2):503-510. 
  76. Molloy GJ, O'Carroll RE, Witham MD, McMurdo ME. Interventions to enhance adherence to medications in patients with heart failure: A systematic review. Circ Heart Fail. 2012;5(1):126-133.
  77. Mortara A, Pinna GD, Johnson P, et al; HHH Investigators. Home telemonitoring in heart failure patients: The HHH study (Home or Hospital in Heart Failure). Eur J Heart Fail. 2009;11(3):312-318.
  78. Nanevicz T, Piette J, Zipkin D, et al. The feasibility of a telecommunications service in support of outpatient congestive heart failure care in a diverse patient population. Congest Heart Fail. 2000;6(3):140-145.
  79. National Institute for Clinical Excellence (NICE). Chronic heart failure. National clinical guideline for diagnosis and management in primary and secondary care. NICE Guideline No. 5. London, UK: NICE; 2003.
  80. Nelson MR, Stepanek J, Cevette M, et al. Noninvasive measurement of central vascular pressures with arterial tonometry: Clinical revival of the pulse pressure waveform? Mayo Clin Proc. 2010;85(5):460-472.
  81. Ohlsson, A, Kubo SH, Steinhaus D, et al. Continuous ambulatory monitoring of absolute right ventricular pressure and mixed venous oxygen saturation in patients with heart failure using an implantable haemodynamic monitor: Results of a 1 year multicenter feasibility study. Eur Heart J. 2001;22:942-954.
  82. Ollendorf DA, Sandhu AT, Chapman R, et al. CardioMEMS HF System (St. Jude Medical) and Sacubitril/Valsartan (Entresto, Novartis) for Management of Congestive Heart Failure: Effectiveness, Value, and Value-Based Price Benchmarks. Final Report. Prepared by the Institute for Clinical and Economic Review (ICER) for the California Technology Assessment Forum (CTAF). San Francisco, CA: CTAF; December 1, 2015. 
  83. Ollendorf DA, Sandhu AT, Chapman R, et al.; Institute for Clinical and Economic Review (ICER). CardioMEMS HF System (St. Jude Medical) and Sacubitril/Valsartan (Entresto, Novartis) for Management of Congestive Heart Failure: Effectiveness, Value, and Value-Based Price Benchmarks. Draft Report. San Francisco, CA: California Technology Assessment Forum (CTAF); September 11, 2015.
  84. Omboni S, Posokhov IN, Rogoza AN. Evaluation of 24-hour arterial stiffness indices and central hemodynamics in healthy normotensive subjects versus treated or untreated hypertensive patients: A feasibility study. Int J Hypertens. 2015;2015:601812.
  85. Palaniswamy C, Mishkin A, Aronow WS, et al. Remote patient monitoring in chronic heart failure. Cardiol Rev. 2013;21(3):141-150.
  86. Pandor A, Thokala P, Gomersall T, et al. Home telemonitoring or structured telephone support programmes after recent discharge in patients with heart failure: Systematic review and economic evaluation. Health Technol Assess. 2013;17(32):1-207, v-vi.
  87. Pickering TG, Hall JE, Appel LJ, et al. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: Blood pressure measurement in humans: A statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Circulation. 2005;111(5):697-716.
  88. Pike E, Bjerkan AM, Fagerlund BC, et al. Continuous monitoring of pulmonary artery pressure via an implanted leadless and battery less pressure sensor for the management of ptients with moderate to severe heart failure (New York Heart Association Class III) [Internet]. Report from the Norwegian Institute of Public Health No. 2016-04. Oslo, Norway: Knowledge Centre for the Health Services at The Norwegian Institute of Public Health (NIPH); October 2016.
  89. Piper MA, Evans CV, Burda BU, et al. Screening for High Blood Pressure in Adults: A Systematic Evidence Review for the U.S. Preventive Services Task Force. Rockville, MD: Agency for Healthcare Research and Quality; December 2014.
  90. Polisena J, Tran K, Cimon K, et al. Home telemonitoring for congestive heart failure: A systematic review and meta-analysis. J Telemed Telecare. 2010;16(2):68-76.
  91. Radhoe SP, Veenis JF, Brugts JJ. Invasive devices and sensors for remote care of heart failure patients. Sensors (Basel). 2021;21(6):2014.
  92. Ramanathan A, Conaghan PJ, Jenkinson AD, Bishop CR. Comparison of ankle-brachial pressure index measurements using an automated oscillometric device with the standard Doppler ultrasound technique. ANZ J Surg. 2003;73(3):105-108.
  93. Richards M. Further studies are needed to assess the benefits of telemonitoring and telephone support for people with heart failure. Commentary. Evid Based Cardiovasc Med. 2005;9(4):322-325.
  94. Roman MJ, Devereux RB, Kizer JR, et al. High central pulse pressure is independently associated with adverse cardiovascular outcome the strong heart study. J Am Coll Cardiol. 2009;54(18):1730-1734.
  95. Roman MJ, Devereux RB. Association of central and peripheral blood pressures with intermediate cardiovascular phenotypes. Hypertension. 2014;63(6):1148-1153.
  96. Rose KM, Arnett DK, Ellison RC, Heiss G. Skip patterns in DINAMAP-measured blood pressure in 3 epidemiological studies. Hypertension. 2000;35(5):1032-1036.
  97. Salavitabar A, Bradley EA, Chisolm JL, et al. Implantable pulmonary artery pressure monitoring device in patients with palliated congenital heart disease: Technical considerations and procedural outcomes. Catheter Cardiovasc Interv 2020;95(2):270-279.
  98. Sandhu AT, Goldhaber-Fiebert JD, Owens DK, et al. Cost-effectiveness of implantable pulmonary artery pressure monitoring in chronic heart failure. JACC Heart Fail.2016;4(5):368-375.
  99. Schmidt S, Schuchert A, Krieg T, Oeff M. Home telemonitoring in patients with chronic heart failure: A chance to improve patient care? Dtsch Arztebl Int. 2010;107(8):131-138.
  100. Schultz MG, Picone DS, Armstrong MK, et al. Validation study to determine the accuracy of central blood pressure measurement using the Sphygmocor Xcel cuff device. Hypertension. 2020;76(1):244-250.
  101. Shaikh AY, Wang N, Yin X, et al. Relations of arterial stiffness and brachial flow-mediated dilation with new-onset atrial fibrillation: The Framingham Heart Study. Hypertension. 2016;68(3):590-596.
  102. Sharman JE, Marwick TH, Gilroy D, et al; Value of Central Blood Pressure for GUIDing ManagEment of Hypertension Study Investigators. Randomized trial of guiding hypertension management using central aortic blood pressure compared with best-practice care: Principal findings of the BP GUIDE study. Hypertension. 2013;62(6):1138-1145.
  103. Shavelle DM, Desai As, Abraham WT, et al; for the CardioMEMS Post-Approval Study Investigators. Lower rates of heart failure and all-cause hospitalizations during pulmonary artery pressure-guided therapy for ambulatory heart failure: One-year outcomes from the CardioMEMS post-approval study. Circ Heart Fail. 2020;13(8):e006863.
  104. Siu AL; U.S. Preventive Services Task Force. Screening for high blood pressure in adults: U.S. Preventive Services Task Force recommendation statement. Ann Intern Med. 2015;163(10):778-786.
  105. Srivastava A, Heywood JT. Replacing art with numbers: decongesting congestive heart failure. Eur J Heart Fail. 2020;22(10):1902-1904.
  106. Teerlink JR. Learning the points of COMPASS-HF: Assessing implantable hemodynamic monitoring in heart failure patients. J Am Coll Cardiol. 2008;51(11):1080-1082.
  107. Textor SC, Taler SJ, Larson TS, Blood pressure evaluation among older living kidney donors. J Am Soc Nephrol. 2003;14(8):2159-2167.
  108. Tice JA. Home telemonitoring for the management of heart failure. Technology Assessment. San Francisco, CA: California Technology Assessment Forum (CTAF); June 29, 2011.
  109. Townsend RR, Black HR, Chirinos JA, et al.  Clinical use of pulse wave analysis: Proceedings from a symposium sponsored by North American Artery. J Clin Hypertens (Greenwich). 2015;17(7):503-513.
  110. U.S. Department of Health and Human Services, Center for Medicare and Medicaid Services (CMS). Self-contained pacemaker monitors. Medicare Coverage Issues Manual §60-7. Baltimore, MD: CMS; 2002.
  111. U.S. Department of Health and Human Services, Center for Medicare and Medicaid Services (CMS). Cardiac pacemaker evaluation services. Medicare Coverage Issues Manual §50-1. Baltimore, MD: CMS; 2002.
  112. U.S. Department of Health and Human Services, Center for Medicare and Medicaid Services (CMS). Durable medical equipment reference list. Medicare Coverage Issues Manual §60-9. Baltimore, MD: CMS; 2002.
  113. U.S. Food and Drug Administration (FDA). FDA approves first implantable wireless device with remote monitoring to measure pulmonary artery pressure in certain heart failure patients. FDA News Release. Silver Spring, MD: FDA; May 28, 2014.
  114. Vanoli E, D'Elia E, La Rovere MT, Gronda E. Remote heart function monitoring: Role of the CardioMEMS HF System. J Cardiovasc Med (Hagerstown). 2016;17(7):518-523.
  115. Veenis JF, Radhoe SP, van Mieghem NM, et al. Remote hemodynamic guidance before and after left ventricular assist device implantation: Short-term results from the HEMO-VAD pilot study. Future Cardiol. 2021;17(5):885-898. 
  116. Verdejo HE, Castro PF, Concepción R, et al. Comparison of a radiofrequency-based wireless pressure sensor to Swan-Ganz catheter and echocardiography for ambulatory assessment of pulmonary artery pressure in heart failure. J Am Coll Cardiol. 2007;50(25):2375-2382.
  117. Wang JT, Frishman WH. Pulmonary pressure monitoring for patients with heart failure. Cardiol Rev. 2017;25(2):53-58.
  118. Weber T, Ammer M, Gunduz D, et al.  Association of increased arterial wave reflections with decline in renal function in chronic kidney disease stages 3 and 4. Am J Hypertens. 2011;24(7):762-769.
  119. Williams B, Lacy PS, Thom SM, et al; CAFE Investigators; Anglo-Scandinavian Cardiac Outcomes Trial Investigators; CAFE Steering Committee and Writing Committee. Differential impact of blood pressure-lowering drugs on central aortic pressure and clinical outcomes: Principal results of the Conduit Artery Function Evaluation (CAFE) study. Circulation. 2006;113(9):1213-1225.
  120. Winkler R, Wild C. Implantation of a wireless pulmonary artery pressure sensor in patients with advanced heart failure [abstract]. Decision Support Document 119. Vienna, Austria: Austrian Institute for Health Technology Assessment (AIHTA); 2020.
  121. Xiao WK, Ye P, Bai YY, et al. Central pulse pressure but not brachial blood pressure is the predominant factor affecting aortic arterial stiffness. Nan Fang Yi Ke Da Xue Xue Bao. 2015;35(1):34-39.
  122. Yancy CW, Jessup M, Bozkurt B, et al.; American College of Cardiology Foundation; American Heart Association Task Force on Practice Guidelines. 2013 ACCF/AHA guideline for the management of heart failure: A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol. 2013;62(16):e147-e239.